1 / 21

Electromagnetic Compatibility Test for CMS Experiment.

Authors C. Rivetta – Fermilab F. Arteche , F. Szoncso, - CERN . Electromagnetic Compatibility Test for CMS Experiment. OUTLINE. 1.Introduction 2. Common Impedance LISN. CDNs. 3.Emission Test Harmonics. RF conducted emission test. 4.Immunity Test RF conducted noise immunity test.

efia
Télécharger la présentation

Electromagnetic Compatibility Test for CMS Experiment.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Authors C. Rivetta– Fermilab F. Arteche , F. Szoncso, - CERN Electromagnetic Compatibility Test for CMS Experiment.

  2. OUTLINE • 1.Introduction • 2. Common Impedance • LISN. • CDNs. • 3.Emission Test • Harmonics. • RF conducted emission test. • 4.Immunity Test • RF conducted noise immunity test. • Slow transients - Surge immunity test. • Fast transients - Burst immunity test. • Voltage dips and short voltage interruptions immunity test • 5.Conclusions 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  3. 1.INTRODUCTION • EMC phenomena are present in CMS • Noise generated by DC-DC converters • Common mode & Differential mode • Transients • Over-voltages • Induced via magnetic fields • Load changes • Switching • Voltage variations • Harmonics • It is important to measure & control them • Goal of these tests • Get the levels of “emission” and “immunity” • Identify possible EMC problems. 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  4. 1.INTRODUCTION • Generic, Basic and military Standards & Aerospace rules. • There are a lot of standards • For practical reasons “ we only consider some of them “ • Emissions test • RF conducted noise(based EN-55011-22 // MIL-STD-461// IEEE Std 1515) • CM & DM ( high and low frequency) • Harmonics (based EN- 61000-3) • Special for 400 Hz power supply distribution system (very low) • Immunity test • Immunity to RF conducted noise (based EN-61000-4-6) • Electrical fast transient burst immunity test (based EN-61000-4-4). • Surge immunity test- Over-voltage (based EN-61000-4-5). • Voltage dips, short interruptions and voltage variations immunity test (based EN-61000-4-11). 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  5. 2. COMMON IMPEDANCE LISN & CDNs • Two kinds of common impedance • Line Impedance Stabilisation Network (LISN) • Coupling De-coupling Network (CDNs) CDNs • Protect auxiliary equipment • Values specified by the standards LISN • Present stable a well defined impedance • Standardise the measurements of test • Values estimated from power cables • HF - Characteristic Impedance (CM & DM ) • Different from commercial LISN • Couple EUT - Measuring equipment. • Standardise the measurement to 50 Ohms 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  6. 2. COMMON IMPEDANCE LISN & CDNs • LISN HCAL Sub-System Zcm =13 Ohms Zdm =42 Ohms 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  7. Measurement equipment Zm LISN EUT 3.EMISION TEST - Harmonics • Effects by pulling the current from power main for only a part of the cycle • Typically rectifiers ( we have 400 Hz power distribution) • Implications • Quality power distribution. • Power supply distribution over-design • Power transformers over-stress • Equipment overheat • Oriented to the 400 Hz PS distribution • AC-Dc converters • Transformers • Limits of harmonics based on international standards & studies. Power supply unit 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  8. 3.EMISION TEST - RF conducted noise • Goal of test control the conducted emission level • Power Supplies & FEE • Frequency Range 9 kHz - 50 MHz • Conducted emissions – Propagation • Common Mode • Group of conductors and ground or other conductors. • Differential Mode • Conductor pairs (Negative-Positive or Phase-Neutral) • Abundant energy exchange between modes CM - DM conversion • System topology as close as possible to final one • Common impedance LISN • Equipment used • Current probes & Spectrum Analyser 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  9. 3.EMISION TEST - RF conducted noise • Power Supply • FEE 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  10. 4.EMISION TEST - RF conducted noise EN-55022 • Test Results Power Supplies • Input • Results refereed to 50 Ohm to compare them with the standards • We used EN - 55022 B • Output • There is no standards so we need to generate them • From this values and the values from Immunity test • FEE • Input • Results refereed to 50 Ohm to compare them with the standards 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  11. 4.IMMUNITY TEST- RF conducted noise • Electromagnetic immunity is the ability,of a device equipment or system to perform without degradation in presence of electromagnetic disturbances • Goal of these tests • Immunity level of FEE and PS to conducted disturbances. • Injection of conducted noise to the FEE • Common impedance - LISN • The idea is inject signal and measurepedestal • Identify frequency areas where the pedestal is not valid • This test will define sensible areas of the FEE • Injection via current probes • It is recommended to Voltage & Current 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  12. Voltage DM measurement LISN Current DM measurement LISN Injection of CM current Voltage DM measurement Current CM measurement LISN Voltage CM measurement 4.IMMUNITY TEST - RF conducted noise • Three different set-ups • DM configuration • 9 kHz / 14 kHz up to 100 MHz • CM at HF configuration • 10 kHz up to 100 MHz • CM at LF configuration • (A few hertz up to 10 kHz) • The value of the amplitude of the signal depends on the sensitivity of the FEE. • This test is complementary of Conducted emission TEST 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  13. 4.IMMUNITY TEST - RF conducted noise - Example I1 • CM ICM 12.05 µA 12 V 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  14. 4.IMMUNITY TEST - RF conducted noise - Example • CM • I1 0.41mA IDM ICM 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  15. 4.IMMUNITY TEST - Surge immunity Test • The goal of test - Determinate the equipment susceptibility to damage by over-voltage generated by • Load changes /Short Circuits /Faults to earth • Common Impedance LISN & CDNs to protect auxiliary equipment • Coupling network will be used to inject the transient • 9 µf & 10 Ohms or 18 µf - Depends on the Test • Pulse Characteristic • Voltage O.Circuit 1.2/50 µs. • Current S.Circuit 8/20 µs • A Zenner / Trans-absorb protect EUT from this emission 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  16. 4.IMMUNITY TEST - Surge immunity Test • The amplitude of the signal • Standards • Electrical environment • 5 Different Class • 0.5 , 1kV , 2 kV, 4 kV • For CMS values • Counting Room - Detector • Class 3 or 4 - (1kV-4 kV) • Balconies - Detector • Not clear • Test simulation for 3 different amplitudes • 1 kV , 500 V , 100 V • Line - Line Trans-absorb Filter FEE CDNs 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  17. 4.IMMUNITY TEST - Surge immunity Test 83 V • It is difficult to find a device to dissipate this power and clamp the voltage within maximum values valid for the FEE. • Level selection • High level • Increase cost or could not have any technical solution • Low level • Increase risk of failure by over-voltage • Final selection based on: • Preliminary studies • Reliability. • Cost • Risk 45 V 15 V 17 kW 4.5 kW 0.3 kW 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  18. 4.IMMUNITY TEST - Burst immunity Test • The goal of test • Fix the susceptibility to damage by over-voltage generated by switching transients. • Common Impedance LISN & CDNs to protect auxiliary equipment. • Coupling network will be used to inject the fast transient - 33 nf. • Pulse Characteristic • Double exponential 5ns/50 ns. • Burst duration ~ 15 ms / 300 ms (1 minute). • Spectra content of signal HF. • Layout very important. • Coupling of burst depends strongly from parasitic capacitance. 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  19. 14 V 9 V 8.5 V 4.IMMUNITY TEST - Burst immunity Test • Class is not defined yet. • Not very important • A simple Capacitor protects to FEE from this emission • Test simulation • 3 different RF capacitors • 5nf, 500nf, 1000nf • Line - Ground • Amplitude • Class 3 - 2 KV. 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  20. 4.IMMUNITY TEST - Voltage dips immunity Test • Noise source • Faults in the networks • Sudden large change of load • Test on FEE • Short interruptions & Voltage variations • Test on Power Supplies • Short interruptions & Voltage variations • Voltage dips • Common impedance LISN • Test level • Standards • Voltage dips • ( 0-40-70%) V nominal - Voltage variations • (0 -40 % ) V nominal. - • For us under study 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

  21. 5. CONCLUSIONS • EMC phenomena is present in CMS • It is important to measure and control them • EMC tests are based on standards and aerospace industry . • EMC test will be focus on conducted noise • Immunity and emissions test • Only a few test will be considered dueto practical reasons • Test levels has not fixed yet • It has a big influence in the elections of filters & protections • It will depend on • Technical studies • Reliability • Cost • Risk 8th Workshop on Electronics for LHC Experiments COLMAR - France, 9-13 September 2002

More Related