Board Replacement for Engineered Glue-Down Hardwood Floors. Board Replacement for Engineered Glue-Down Hardwood Floors. Why Replace a Board?. Damage to existing board Manufacturing defect Aesthetic changes. Board Replacement for Engineered Glue-Down Hardwood Floors. Tools to be Used.

efuru
Télécharger la présentation

Board Replacement for Engineered Glue-Down Hardwood Floors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Board Replacement for Engineered Glue-Down Hardwood Floors

  2. Board Replacement for Engineered Glue-Down Hardwood Floors Why Replace a Board? • Damage to existing board • Manufacturing defect • Aesthetic changes

  3. Board Replacement for Engineered Glue-Down Hardwood Floors Tools to be Used

  4. Board Replacement for Engineered Glue-Down Hardwood Floors Layout the Areas to be Cut With a marking pen layout the areas to be cut approximately ½” from the side joints

  5. Board Replacement for Engineered Glue-Down Hardwood Floors Drill Holes at the Corners to Prevent Damage to Adjoining Boards

  6. Board Replacement for Engineered Glue-Down Hardwood Floors Cutting the Areas Marked Care must be taken not to cut into adjoining boards

  7. Board Replacement for Engineered Glue-Down Hardwood Floors Setting the Saw to cut the thickness of the board

  8. Board Replacement for Engineered Glue-Down Hardwood Floors Make a Cut Down the Center for Easy Removal

  9. Board Replacement for Engineered Glue-Down Hardwood Floors Carefully Remove the End Pieces

  10. Board Replacement for Engineered Glue-Down Hardwood Floors Release the Remaining ½” of the Edge Loose from the Adhesive

  11. Board Replacement for Engineered Glue-Down Hardwood Floors Clean any Remaining the Adhesive to a Thin Residue

  12. Board Replacement for Engineered Glue-Down Hardwood Floors Mark the Replacement Board to Length

  13. Board Replacement for Engineered Glue-Down Hardwood Floors Cut the Board to Length

  14. Board Replacement for Engineered Glue-Down Hardwood Floors Remove the Bottom of the Groove on the Side and End

  15. Board Replacement for Engineered Glue-Down Hardwood Floors Apply the Adhesive to the Back of the Material with a Notched Spreader

  16. Board Replacement for Engineered Glue-Down Hardwood Floors Optional: Place a Bead of Glue on the Top of the Tongue

  17. Board Replacement for Engineered Glue-Down Hardwood Floors Insert the Tongue and Drop into Place

  18. Board Replacement for Engineered Glue-Down Hardwood Floors Clean and Fill as Necessary

  19. Board Replacement for Engineered Glue-Down Hardwood Floors Weight Overnight if Necessary