Quality Assurance/ Quality Control

Quality Assurance/ Quality Control. Nate Herbst Southern Ute Indian Tribe. Intro to QA/QC. Getting good data requires many different steps Data quality objectives (DQOs) developed DQOs for ozone being developed Measurement quality objectives (MQOs) for ozone exist

ekram
Télécharger la présentation

Quality Assurance/ Quality Control

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Quality Assurance/ Quality Control Nate Herbst Southern Ute Indian Tribe

  2. Intro to QA/QC • Getting good data requires many different steps • Data quality objectives (DQOs) developed • DQOs for ozone being developed • Measurement quality objectives (MQOs) for ozone exist • Analysis begun (after correct calibration) • QC checks performed • QA conducted

  3. Data Quality Objectives (7 steps) • State problem • Define why monitoring is needed • Create team and purpose • Identify decision • What decision will be made with data? • Identify decision inputs • What data necessary to make decision? • Define boundaries • What are study area boundaries?

  4. Data Quality Objectives (cont.) • Develop decision rule • What conditions will require action (action level)? • Specify decision error limits • What margin of error is allowable • Optimize monitoring design • Develop most cost-effective method of reaching DQOs • EPA hasn’t yet defined DQOs for ozone analysis

  5. DQOs (cont.) Diagram of DQO steps (Diagram courtesy of U.S. Department of Energy – DQO homepage)

  6. Measurement Quality Objectives (MQOs) Thanks to Melinda Ronca-Batista (ITEP) • EPA has ozone analysis MQOs • Use these in element 7 of your QAPP • MQOs in a nutshell • Shelter temperature kept between 20-30oC ± 2oC • Analyzer must be reference or equivalent method • Lower detectable limit 0.01ppm, noise 0.005ppm • Data completeness 75% of hourly values between 9:01am and 9:00pm (for the ozone season) • Transfer standard certification ±4% or 4ppb (whichever is greater)

  7. MQOs (cont.) • Transfer standard re-certification to primary std.dev 1.5% • Local primary standard certification ±5% of reference • EPA reference photometer regression slope 1.00 ± 0.01 • Zero air free of O3 and anything that might react with O3

  8. MQOs (cont.) • Ozone analyzer calibration • Z/S check zero ±10ppb, span ± 15% • 5pt calibration linearity error ±5% • Performance (NPAP) mean absolute difference ± 15% • Precision (quarterly) 95% CI < ±15% • Audits (annually) 95% CI < ±20%

  9. Quality Assurance Project Plans (QAPPs) • Contain 24 “elements” • Element 7 is where MQOs go • Cut and paste from red book • Ensure data quality • Required by EPA • Developed by program approved by EPA • They must be followed! • No good if not followed

  10. Documentation • Document everything!!! • Documentation in • Logbooks • Site folders • QA/QC field forms • Anywhere else you think is appropriate • QA/QC – document standard values and response

  11. Documentation (cont.) • Document repairs, checks, fine tunes • Document site conditions • Document everything that could ever be important • Write only in pen (black if possible) • Cross out errors with a single line

  12. Slope = rise over run m = slope b = intercept (where the trend-line crosses the Y axis) r2 close to 1 shows correlation Linearity

  13. Instrument Calibration • Measurements require point of reference • Measurement without standard is impossible • Calibration involves setting instrument to known level • Calibrations performed fairly regularly • When monitoring is begun • When repairs or maintenance are performed • When precision checks or audits show need • Calibrations must be done correctly

  14. Calibrations (cont.) • Calibration = setting analyzer to standard • Data only good within linear range (~0-0.400ppm) • Calibration followed by a 5-pt check • Analyzer must agree with standard at all 5 pts • Linearity error < 5% • See next slide on linearity • Monitoring begins after calibration Note: Never initiate monitoring without calibration

  15. Not always necessary Can do 5-pt check Analyzer must be calibrated The r2 value and % differences for each point are unacceptable Pre-Calibration Check

  16. Instrument Calibration • Calibrate instrument to the standard • Use calibration point near URL • Setting low produces large error at URL • Set standard to ~0.400 ppm • Let analyzer stabilize • Calibrate analyzer • Do new 5-pt check

  17. Is analyzer response within 7% at each point? Would you put this analyzer online? Post-Calibration 5-pt Check

  18. Quality Control (QC) • QC involves “in-house” verifications • Also referred to as precision checks • Verifications are comparisons between transfer standard and analyzer • Relative % difference within allowable margin? • Verifications determine monitoring repeatability • Standard deviation • Different types of verifications

  19. QC (cont.) • Level 1: 40 CFR, Pt. 58, App. A, Table A-1 defines ozone verification requirements (for SLAMS) • Biweekly response check between 0.08 and 0.1 ppm • Comparison between analyzer and standard • Determines repeatability • Level 2: “extra” precision checks • Weekly “span level” (~80% URL) checks • Quarterly 5-pt checks • Determines analyzer performance trends

  20. Quality Assurance (QA) • QA involves “external” checks • Referred to as “audits” • Audits involve comparison between transfer standard and analyzer • Accuracy levels must be within ±10% • Audits determine how close monitoring gets to actual values • Different types of audits

  21. QA (cont.) • 40 CFR, Pt. 58, App. A, Table A-1 defines ozone audit requirements (for SLAMS) • Annual (and other) response checks at multiple points • 0.03-0.08 ppm • 0.15-0.2 ppm • 0.35-0.45 ppm • Comparison between analyzer and external standard • Audits should include zero check

  22. QA (cont.) • Different types of audits • By reporting organization (RO) certified by RO • By RO certified by other than RO • By other than RO certified by other than RO

  23. Precision & Accuracy (P&A) Data • Precision data come from biweekly precision checks • Accuracy data come from annual and other audits • P&A data validate ambient data • P&A data must be included in AQS data submittals

  24. Siting Criteria • Data quality depends on correct siting of all instrumentation • Specific instrument siting guidelines • Following guidelines is vital part of quality assurance and control • We’ll learn more about these guidelines in the next presentation

  25. Summary • Establish DQOs • Develop QAPP • Get it approved by EPA • Follow your QAPP • Conduct bi-weekly precision checks • Conduct level 2 checks to follow monitor trends • Participate in annual audits and others if possible • Data quality will be guaranteed