1 / 24

PHOENICS User Conference 2004

PHOENICS User Conference 2004. “Applying CFD to Environmental Flows” Eric Jal Connell Wagner, Melbourne, Australia 3-5 May 2004 - Melbourne, Australia. Introduction. Environmental consequences within the built environment are becoming a crucial issue in engineering project developments

elton-pope
Télécharger la présentation

PHOENICS User Conference 2004

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PHOENICS User Conference 2004 “Applying CFD to Environmental Flows” Eric Jal Connell Wagner, Melbourne, Australia 3-5 May 2004 - Melbourne, Australia

  2. Introduction • Environmental consequences within the built environment are becoming a crucial issue in engineering project developments • Increasingly common to use CFD in the design process to assess and optimise environmental flow impacts relating to:- • pedestrian comfort and safety • exhaust emissions • airborne dispersion • snow deposition

  3. Project Case Studies • PHOENICS CFD code has been used • TECPLOT used for results visualisation • Several case studies will be presented:- • City Square - Melbourne, Australia • Holdfast Shores - Adelaide, Australia • Urban City Planning - Wellington, NZ • Perisher Valley Resort - NSW, Australia • City Link Stack - Melbourne, Australia • Holden Sand Bins - Melbourne, Australia

  4. Case Study - City Square City Square - Melbourne, Australia

  5. City Square - Design Scope • The Melbourne CBD City Square precinct incorporates an underground car park • Due to architectural constraints the exhaust stack is through a street level cafe • Concerns were raised of the discharge upon café patrons and upon adjacent buildings (hotel with exposed balconies) • CFD study conducted to assess effect of stack discharge for different wind condition • Provide optimised stack solution

  6. City Square - Design Analysis Exhaust Discharge : 3m/s Southerly Wind (22oC Day)

  7. City Square - Design Analysis Exhaust Discharge : 3.5m/s Westerly Wind (22oC Day)

  8. Case Study - Holdfast Shores Holdfast Shores - Adelaide, Australia

  9. Holdfast Shores - Design Scope • Multi-use precinct development situated at Glenelg on Adelaide’s coastal strip • Pedestrian comfort and safety concerns on a footbridge due to it’s position (“wind-gully”) • CFD modelling analysis was conducted • Assessment performed of various proposed ‘wind-break’ structures (with key aesthetic feature must have minimal visual impact)

  10. Holdfast Shores - Design Analysis Environmental Wind Flow : 9.25m/s Westerly Wind

  11. Case Study - Urban City Planning Urban City Planning - Wellington, New Zealand

  12. Urban City Planning - Design Scope • Pedestrian comfort and safety aspects are a prominent issue for urban city planning • In Wellington specific rules apply as proviso for permitted building developments (over four storeys high) • Property developers and designers must demonstrate no adverse effects on the local wind conditions around the building vicinity • Establish that CFD can be a useful tool

  13. Urban City Planning - Design Analysis Environmental Wind Flow : 21m/s Northerly Wind

  14. Case Study - Perisher Valley Resort Perisher Valley Resort - NSW, Australia

  15. Perisher Valley Resort - Design Scope • Issues were raised during Environmental Impact Statement (EIS) concerning likely snow drifting around redeveloped resort • Two configurations were analysed with CFD to establish snow deposition around the buildings and pedestrian concourse areas • A two-phase CFD model was developed • The study demonstrated that CFD could be utilised as a practical tool for architectural planning purposes

  16. Perisher Valley Resort - Design Analysis Environmental Wind Flow : 25km/hr WSW Wind

  17. Case Study - City Link Burnley Stack City Link Burnley Stack - Melbourne, Australia

  18. City Link Burnley Stack - Design Scope • Emissions from the vent stacks need to be monitored (EPA policy) to ensure pollutant concentrations are within statutory levels • During commissioning it was found that the discharge flow within the exhaust stack was non-uniform and as a consequence the flow could not be sampled and measured • CFD study was undertaken to establish flow characteristics and determine a satisfactory solution to overcome the problem

  19. City Link Stack - Design Analysis Stack Exhaust : As Built Configuration

  20. City Link Stack - Design Analysis Stack Exhaust : Modified Shaft Geometry Configuration

  21. Case Study - Fugitive Emissions Fugitive Emissions : Industrial Sand Storage Bins

  22. Conclusions • Project case studies have shown the use of CFD for assessing and optimising solutions related to environmental flows • Issues relating to exhaust emissions, snow deposition, airborne dispersion, pedestrian comfort and safety can be addressed with CFD and can also provide cost benefits • Anticipated that CFD will be a useful tool and essential aid for urban developers, architectural designers and environmental planners for the built environment design

  23. Presentation End a Thankyou!

More Related