Design of RP-HPLC 1 for Insulin Production

Design of RP-HPLC 1 for Insulin Production. Presented by: Patricia Yee, Nicholas Irianto, Thomas Fang. Overview. Background Information Significance of RP-HPLC1 Design Parameters Selected Design and Specifications Questions. Background Information. What is HPLC ?

evania
Télécharger la présentation

Design of RP-HPLC 1 for Insulin Production

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design of RP-HPLC 1 for Insulin Production Presented by: Patricia Yee, Nicholas Irianto, Thomas Fang

  2. Overview • Background Information • Significance of RP-HPLC1 • Design Parameters • Selected Design and Specifications • Questions

  3. Background Information • What is HPLC? • High Performance Liquid Chromatography - or - • High-Pressure Liquid Chromatography

  4. How HPLC works…

  5. Reverse-Phase HPLC

  6. Insulin Production Process:RP-HPLC 1

  7. Insulin Production Process:RP-HPLC 1 • What comes out… 1) Contaminated protein, denatured insulin, enzyme and small amounts of insulin ester and WFI 2) Majority of desired insulin ester and WFI

  8. Insulin Production Process:RP-HPLC 1 • Gradient Elution of mobile phase: • Acetonitrile / Water / Acid

  9. Main Design Parameters • Column • Size (Internal diameter) • Material (Stainless Steels, Glass, etc)

  10. Main Design Parameters • Resin • Particle size (10μm ~75μm ) • Pore size (300 Á) • Material (Silica, styrene-divinylbenzene, etc.)

  11. Other Design Considerations • Pump (pressure capacity) • Solvent • Acetonitrile • Polar solvent (increase retention time) • Hydrophobic solvent (decrease retention time)

  12. Possible Design

  13. Design Specifications • 100% binding and 90% yield for insulin ester • 60% binding and 5% yield for denatured insulin precursors • Purification results in outlet stream consisting of 340 kg insulin ester/batch

  14. Design Selections • HPLC Columns • Novasep Prochrom® DAC Columns LC1600 • H x D: 450 x 1600 mm • HPLC Resins • PRP-3 standard Poly(styrene-divinylbenzene) (PSDVB) • Pore size 300 Å • Diameter 10 μm

  15. Design Justifications • Stable from pH 1-13 • Does not contain acidic silanol groups, which are present on silica supports. • Highly cross-linked for exceptional durability and to prevent shrinking and • Consistent performance • 10μm particle diameter is selected for better solution and peak shape

  16. Design Details • Twenty three LC 1600 HPLC column units with 0.91 hours process time would be required for the process according to SuperPro • For one LC 1600 HPLC column with maximum bed volume of 900 L would require 360 000 grams of PRP-3 resins COSTS • $24/g of PRP-3 resins This translates to $ 8 640 000 / LC 1600 HPLC column For 23 HPLC columns, it would cost $ 198 720 000 • $28 000 for a Novasep Prochrom DAC LC 1600 column Total Cost $ 200 000 000

  17. Questions? THANK YOU!