Chapter 4: Basic Properties of Feedback

Chapter 4: Basic Properties of Feedback. Chapter Overview. Perspective on Properties of Feedback. Control of a dynamic process begins with: a model , & a description of what the control is required to do. Examples of Control Specifications. Stability of the closed-loop system

fawzi
Télécharger la présentation

Chapter 4: Basic Properties of Feedback

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 4: Basic Properties of Feedback Chapter Overview

  2. Perspective on Properties of Feedback Control of a dynamic process begins with: • a model, & • a description of what the control is required to do.

  3. Examples of Control Specifications • Stability of the closed-loop system • The dynamic properties such as rise time and overshootin response to step in either the reference or the disturbance input. • The sensitivity of the system to changes in model parameters • The permissible steady-state error to a constant input or constant disturbance signal. • The permissible steady-state tracking error to a polynomial reference signal (such as a ramp or polynomial inputs of higher degrees)

  4. Learning Goals • Open-loop & feedback control characteristics with respect to steady-state errors (= ess) in: Sensitivity Disturbance rejection (disturbance inputs) & Reference tracking to simple parameter changes. • Concept of system type and error constants • Elementarydynamic feedback controllers: P, PD, PI, PID

  5. Chapter 4: Basic Properties of Feedback Part A: Basic Equation of Unity Feedback Control

  6. Block Diagram controller disturbance plant input error output forward path amplification gain or transfer function of the plant sensor noise

  7. Closed-Loop Transfer Function Case 1: D = 0 and N = 0

  8. Closed-loop Transfer Function Case 2: R = 0 and D = 0

  9. Closed-loop Transfer Function Case 3: R = 0 and N = 0

  10. Closed-loop Transfer Function Case 4: R, D, N 0

  11. Error Case 4: R, D, N 0

  12. Chapter 4: Basic Properties of Feedback Part B: Comparison between Open-loop and Feedback Control

  13. 1.Sensitivity of Steady-State System Gain to Parameter Changes • The change might come about because of external effects such as temperature changes or might simply be due to an error in the value of the parameter from the start. • Suppose that the plant gain in operation differs from its original design value of G to be G+δG. • As a result, the overall transfer function T becomes T+δT.

  14. Sensitivity of System Gain to Parameter Changes • By definition, the sensitivity, S, of the gain, G, with respect to the forward path amplification, Kp, is given by:

  15. Sensitivity of System Gain in open-loop control In an open-loop control, the output Y(s) is directly influenced by the plant model change δG.

  16. Sensitivity of System Gain in closed-loop control In a feedback control, the output sensitivity can be reduced by properly designing Kp

  17. 2. Disturbance Rejection • Suppose that a disturbance input, N(s), interacts with the applied input, R(s). • Let us compare open-loop control with feedback control with respect to how well each system maintains a constant steady state reference output in the face of external disturbances

  18. Disturbance Rejection in open-loop control In an open-loop control, disturbances directly affects the output.

  19. Disturbance Rejection in closed-loop control In a feedback control, Disturbances D can be substantially reduced by properly designing Kp

  20. 3. Reference Tracking in closed-loop control In a feedback control, an input R can be accurately tracked by properly designing Kp

  21. 4. Sensor Noise Attenuation in closed-loop control In a feedback control, the noise R can be substantially reduced by properly designing Kp

  22. 5. Advantages of Feedback in Control Compared to open-loop control, feedback can be used to: • Reduce the sensitivity of a system’s transfer function to parameter changes • Reduce steady-state error in response to disturbances, • Reduce steady-state error in tracking areference response (& speed up the transient response) • Stabilize an unstable process

  23. 6. Disadvantages of Feedback in Control Compared to open-loop control, • Feedback requires asensor that can be very expensive and may introduce additional noise • Feedback systems are often more difficult to design and operate than open-loop systems • Feedback changes the dynamic response (faster) but often makes the system less stable.

  24. Chapter 4: Basic Properties of Feedback Part C: System Types & Error Constants

  25. Introduction • Errors in a control system can be attributed to many factors: • Imperfections in the system components (e.g. static friction, amplifier drift, aging, deterioration, etc…) • Changes in the reference inputs cause errors during transient periods & may cause steady-state errors. • In this section, we shall investigate a type of steady-state error that is caused by the incapability of a system to follow particular types of inputs.

  26. Steady-State Errors with Respect to Types of Inputs • Any physical control system inherently suffers steady-state response to certain types of inputs. • A system may have no steady-state error to a step input, but the same system exhibit nonzero steady-state error to a ramp input. • Whether a given unity feedback system will exhibit steady-state error for a given type of input depends on the type of loop gain of the system.

  27. Classification of Control System • Control systems may be classified according to their ability to track polynomial inputs, or in other words, their ability to reach zero steady-state to step-inputs, ramp inputs, parabolic inputs and so on. • This is a reasonable classification scheme because actual inputs may frequently be considered combinations of such inputs. • The magnitude of the steady-state errors due to these individual inputs are indicative of the goodness of the system.

  28. The Unity Feedback Control Case

  29. Steady-State Error • Error: • Using the FVT, the steady-state error is given by: FVT

  30. Steady-state error to polynomial input- Unity Feedback Control - • Consider a polynomial input: • The steady-state error is then given by:

  31. System Type A unity feedback system is defined to be type k if the feedback system guarantees:

  32. System Type (cont’d) • Since, for an input the system is called a type k system if:

  33. Example 1: Unity feedback • Given a stable system whose the open-loop transfer function is: subjected to inputs • Step function: • Ramp function:  The system is type 1

  34. Example 2: Unity feedback • Given a stable system whose the open-loop transfer function is: subjected to inputs • Step function: • Ramp function: • Parabola function:  type 2

  35. Example 3: Unity feedback • Given a stable system whose the open loop transfer function is: subjected to inputs • Step function: • Impulse function:  The system is type 0

  36. Summary – Unity Feedback • Assuming , unity system loop transfers such as:  type 0  type 1  type 2  type n

  37. General Rule – Unity Feedback • An unity feedback system is of type k if the open-loop transfer function of the system has: k poles at s=0 In other words, • An unity feedback system is of type k if the open-loop transfer function of the system has: k integrators

  38. Error Constants • A stable unity feedback system is type k with respect to reference inputs if the openloop transfer function has k poles at the origin: Then the error constant is given by: • The higher the constants, the smaller the steady-state error.

  39. Error Constants • For a Type 0 System, the error constant, called position constant, is given by: • For a Type 1 System, the error constant, called velocity constant, is given by: • For a Type 2 System, the error constant, called acceleration constant, is given by: (dimensionless)

  40. Steady-State Errors as a function of System Type – Unity Feedback

  41. Example: • A temperature control system is found to have zero error to a constant tracking input and an error of 0.5oC to a tracking input that is linear in time, rising at the rate of 40oC/sec. • What is the system type? • What is the steady-state error? • What is the error constant? The system is type 1

  42. Conclusion • Classifying a system ask type indicates the ability of the system to achieve zero steady-state error to polynomials r(t) of degree less but not equal to k. • The system is type k if the error is zero to all polynomials r(t) of degree less than k but non-zero for a polynomial of degree k.

  43. Conclusion • A stable unity feedback system is type k with respect to reference inputs if the loop transfer function has k poles at the origin: • Then the error constant is given by:

  44. Chapter 4: Basic Properties of Feedback Part D: The Classical Three- Term Controllers

  45. Basic Operations of a Feedback Control Think of what goes on in domestic hot water thermostat: • The temperature of the water is measured. • Comparison of the measured and the required values provides an error, e.g.“too hot’ or ‘too cold’. • On the basis of error, a control algorithm decides what to do.  Such an algorithm might be: • If the temperature is too high then turn the heater off. • If it is too low then turn the heater on • The adjustment chosen by the control algorithm is applied to some adjustable variable, such as the power input to the water heater.

  46. Feedback Control Properties • A feedback control system seeks to bring the measured quantity to its required value or set-point. • The control systemdoes not need to know why the measured value is not currently what is required, only that is so. • There are two possible causes of such a disparity: • The system has been disturbed. • The setpoint has changed. In the absence of external disturbance, a change in setpoint will introduce an error. The control system will act until the measured quantity reach its new setpoint.

  47. The PID Algorithm • The PID algorithm is the most popular feedback controller algorithm used. It is a robust easily understood algorithm that can provide excellent control performance despite the varied dynamic characteristics of processes. • As the name suggests, the PID algorithm consists of three basic modes: the Proportional mode, the Integral mode & the Derivative mode.

  48. P, PI or PID Controller • When utilizing the PID algorithm, it is necessary to decide which modes are to be used (P, I or D) and then specify the parameters (or settings) for each mode used. • Generally, three basic algorithms are used: P, PI or PID. • Controllers are designed to eliminate the need for continuous operator attention.  Cruise control in a car and a house thermostat are common examples of how controllers are used to automatically adjust some variable to hold a measurement (or process variable) to a desired variable (or set-point)

  49. Controller Output • The variable being controlled is the output of the controller (and the input of the plant): • The output of the controller will change in response to a change in measurement or set-point (that said a change in the tracking error) provides excitation to the plant system to be controlled

  50. PID Controller • In the s-domain, the PID controller may be represented as: • In the time domain: proportional gain integral gain derivative gain