1 / 9

Relativistic Electron Lab

Relativistic Electron Lab. In this lab you will measure both the momentum and kinetic energy of electrons emitted from a radioactive source ( b particles)

feng
Télécharger la présentation

Relativistic Electron Lab

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Relativistic Electron Lab • In this lab you will measure both the momentum and kinetic energy of electrons emitted from a radioactive source (b particles) • The basic idea is to see that these quantities require the use of relativistic equations and that classical equations do not work since the maximum b energy is 766 keV • You will also measure the rest mass of the electron and the speed of light in the lab.

  2. Relativistic momentum Remember this is a relativistic problem: F = evB = γma (since F is perpendicular to v; otherwise it’s more complex); but a = v2/r so that evB = γmv2/r ; solving for r, we have r = γmv/eB = p/eB so that we have p = eBr

  3. Experiment Overview • First you’ll calibrate the multichannel analyzer so that we have a correspondence between channel number and detected particle energy • Second you’ll measure the fixed radius of the orbit and the slit widths (so you’ll know the spread in r) • Third, you’ll set and measure B (fixing p), and then count all detected particles that have a corresponding kinetic energy

  4. Further Details - 1 • Chamber is evacuated using a mechanical pump • B is measured using a Hall probe – must be oriented properly to read B field in chamber (Hall probe) • Source is a 10 mCi204Tl beta emitter • Detector is silicon surface-barrier detector – a stopped charge particle produce ionization whose total charge is proportional to the energy of the particle – this charge is collected at an electrode (due to a 550 V potential applied across it). The current pulse is then integrated by a pre-amp to produce a voltage pulse with an amplitude proportional to the particle energy – this is amplified by a linear amplifier and analyzed by a MCA to perform a PHA. • The duration of the experiments should depend on B, with longer experiments needed as B increases (range 5 to 12 hours)

  5. Relativistic energy Relativistic kinetic energy is given by: Manipulating this equation, we find: Or: Solving for p2:

  6. Data Analysis • You will, for each B, measure the kinetic energy of the detected electrons • Then from our derived equation connecting K and p: You can plot this as y = (1/c2)x + m to find values for c and m for the electron and to see that the relativistic equations are correct vs the classical K = p2/2m

  7. Further Details – 2 • For each B, determine p with its uncertainty • For each spectrum, determine the centroid of the relativistic electron peak (in keV), its full-width-at-half-maximum (FWHM, also in keV), and the net area (number of electrons) in the peak • In your graph, also plot classical and relativistic theory and error bars on the points

  8. This is a Collaborative Lab • We will, all together, calibrate the MCA, you will measure the geometry of the chamber; then we’ll set-up and start the first run • You will each take data on a schedule – • You will need to: • Stop and save the experiment (in .SPC format) • Analyze the peak and record values • Re-measure the B field, after zeroing, and record • Re-set the B field, measure and record new value • Clear data and re-start experiment

  9. Schedule • Tuesday – group: calibrate, measure and start B = 500 G #1: ~6 h later – start B = 600 G #2: Wed. AM – start 700 G #3: late PM – start 800 G #4: early Thurs AM – start 900 G #5: Thurs evening – start 1000 G #6: Friday AM – end and initial plot data; decide if more needed (consult with me) and start new run or close down Room Key – outer and inner door keys hidden outside N008

More Related