Maciej Bromirski Thermo Fisher Scientific (Bremen, Germany) Denver, June 8, 2011

Investigation of Oxidative and Conjugative Metabolism Reactions with Liquid Chromatography / Accurate Mass High Resolution Mass Spectrometry. Maciej Bromirski Thermo Fisher Scientific (Bremen, Germany) Denver, June 8, 2011. Why?.

garret
Télécharger la présentation

Maciej Bromirski Thermo Fisher Scientific (Bremen, Germany) Denver, June 8, 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Investigation of Oxidative and Conjugative Metabolism Reactions with Liquid Chromatography / AccurateMass High Resolution Mass Spectrometry Maciej Bromirski Thermo Fisher Scientific (Bremen, Germany) Denver, June 8, 2011

  2. Why? • In metabolic studies, the identification of metabolites in blood or urine samples as well as liver microsome incubations is relatively easy, but the detection of reactive species turns out to be tricky • Trapping experiments deliver only indirect proof of identitiy • Electrochemical simulations of metabolic processes, coupled to high performance liquid chromatography (HPLC), have been shown to be a simple and fast alternative to classical approaches • Combination of electrochemistry with high resolution accurate mass (HRAM) mass spectrometry may deliver enhanced sensitivity and confidence in metabolite detection, especially for reactive metabolites

  3. Methods

  4. Experimental Setup • For the shown experiments a ROXY™ potentiostat equipped with a Reactor Cell™ thin layer flowcell from Antec B. V. (Zoeterwoude, The Netherlands) was used, coupled to a Thermo Scientific Exactive Benchtop Orbitrap mass spectrometer • Analyte solutions were provided in water / acetonitrile 1:1 with 0.1% formic acid • Protein solutions for conjugation experiments were provided in 10 mM ammonium formiate solution, adjusted to pH 7.8

  5. The ROXY potentiostat

  6. Infusion experiments for Phase I and Phase II studies only analyte passing EC cell is analysed Phase I studies conjugation of reaction products with protein after EC cell Phase II studies

  7. Setup with chromatographic separation reaction products are trapped in injection loop content of injection loop is passed to column

  8. Exactive™ - specification • Resolution • 100,000 at 1 scan per second • 10,000 at 10 scans per second • Mass accuracy • ppm mass accuracy • Sensitivity • 500 fg Buspirone > 10:1 • Dynamic Range • >4000 within a spectrum • Scan speed • Up to 10 scans per second • Mass Range • m/z 50 - 4000 • Polarity switching • Yes, 1 full cycle <1 sec

  9. Metabolites of a pesticide:Thiamethoxam

  10. Reaction products of Thiamethoxam C8H11ON4ClS Thiamethoxam C8H10O3N5ClS C8H12O3N4S C7H13O5N3 C8H12O1N5ClS C8H10O2N5ClS C8H10O2N4S -H2? +O C8H10O4N5ClS C8H11O5N5S

  11. Voltammogram of selected reaction products Thiamethoxam M1 m/z 308 M2 m/z 290 M3 m/z 276 M4 m/z 262 M5 m/z 247 M6 m/z 245 M7 m/z 230

  12. Reaction product 1: Oxygenated Thiamethoxam?  YES!

  13. ... and it is not Glutathion

  14. Reaction product 2: Dehydrogenated Thiamethoxam?  NO!

  15. ... but what else is it??? • Dehydrogenated Thiamethoxam: C8H8O3N5ClS •  exact mass 290.01091 • Measured mass: 290.05487 •  on an Exactive, this is a clear mismatch • Proposed elemental composition: C8H11O5N5S • Proposed structure:

  16. Metabolites of a drug:Ticlopidin

  17. Reaction products of Ticlopidin 0.0 V EC potential 2.5 V EC potential

  18. Metabolites confirmed by microsome incubation1 • 264.0594: Ticlopidin • 262.0441: Ticlopidin – 2H • 260.0290: Ticlopidin – 4H • 278.0390: Ticlopidin – 2H + O • 280.0544: Ticlopidin + O 1 Davie et al., DMD 32:49–57, 2004

  19. A closer look on the oxygenation products C14H12ONClS Ticlopidin – 2H +O Δm 1.3 ppm C14H14ONClS Ticlopidin +O Δm 1.1 ppm

  20. Summary • Metabolites can be detected with high sensitivity and specificity • Ultra high resolution provides clear separation from interferences • Unique scan-to-scan mass accuracy provides clear distinction of false positives from correct signals • High confidence in identification is provided

  21. Acknowlegements • Antec B. V., Zouterwoude, The Netherlands • Agnieszka Kraj • University of Muenster, Germany • Uwe Karst • Anne Baumann • Thorsten Vielhaber • Thermo Fisher Scientific, Germany • Olaf Scheibner

  22. ?