An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Exterior Magnets ConceptBlanket and Vacuum Vessel Chamber Integration and Maintenance G. Sviatoslavsky, M. Sawan (UW), A.R. Raffray (UCSD),

  2. Outline • Chamber Layout • Blanket Maintenance • Dump Maintenance • Design Assessment in Terms of Givens and Druthers Fusion Technology Institute

  3. Chamber Cut-away Polar Cusp Armored Dump Module Pole Blanket module Mid Blanket modules (16 upper & 16 lower) Ring Cusp Armored Dump Shield/VV Magnets Fusion Technology Institute

  4. Nested polar modules allow VV access without disturbing beam ducts or magnets VV Module Housing Polar Cusp Armored Dump VV Module housing Polar Blanket External manifold (not shown) allows hands-on pipe connection & disconnection Fusion Technology Institute

  5. Blanket Maintenance Scheme Self-contained remote handling system attaches vessel at pole Fusion Technology Institute

  6. Blanket Maintenance Scheme Fusion Technology Institute

  7. Blanket Maintenance Scheme Fusion Technology Institute

  8. Blanket Maintenance Scheme Fusion Technology Institute

  9. Blanket Module with Frame and Coolant Manifold Module Frame Coolant inlet and outlet manifolds Chamber attachment points • Frame is one option • Provides module/vessel clearance required for manifold • Frame requires cooling • Another option: mount attachment points directly onto sub-modules • Another manifold option is to have concentric inlet/outlet piping Fusion Technology Institute

  10. Tee Nut Remote Fasteners Fixed mounting receptacles mounted on module frame • Captive nut / bolt fasteners • Utilized in TPX divertor module mounting • Allows some lateral movement to accommodate thermal expansion • Fastener tightened outside the chamber due to space constraints at module/chamber interface Nut Bar mechanism integrated into chamber and manipulated from outside of chamber Fusion Technology Institute

  11. Attachment Point Detail • Module is aligned to engage nut bar through “keyed” opening of receptacle • Rotation of nut bar is stopped at 900 • Additional rotation tightens nut bar against receptacle keyed wall Fixed mounting receptacle for clamping with nut bar Fusion Technology Institute

  12. Cut-Away View of Module/Chamber Interface Shield wall Nut bar tightened from outside of chamber Blanket Module Module frame Fixed mounting receptacle Chamber Support I-beam Manifold inlet & outlet connection Fusion Technology Institute

  13. Tee Bar Fastener detail Tee bar fastener tightened from outside of chamber Module frame Length of linkage through shield provides “flexibility” to accommodate thermal expansion Fixed mounting receptacle Shield Module Fusion Technology Institute

  14. Manifold Connection Detail Option 1: External welding possible with proper installation alignment Option 2: ~ 11” inlet & outlet pipes allows internal welding Shield Coolant penetrations through shield) (two shown but concentric option requires only one) Fusion Technology Institute

  15. Maintenance of Ring Cusp Dump Removable “Ring Caps” at equator Possibly replaceable ring cap modules with integrated dumps plates Fusion Technology Institute

  16. Givens & Druthers – All Noncompliance • Does not allow “Straight-up” blanket removal • Field coil radii: 4.1m & 6.9m vs. 3.4m & 6.1m (radius measured to center of coil cross-section) • Blanket offset from shield by only ~35cm Fusion Technology Institute

  17. Givens & Druthers – Highlighted Compliance • Blanket access does not require re-welding beam ports • Blanket Access does not require disconnecting (or moving) beam ports • Minimizes mass lifted for chamber access • Minimizes height of components to be lifted • Minimizes evacuated volume Fusion Technology Institute

  18. Additional Advantages • Blanket access does not require disturbing magnets • Magnets accessible for hands-on maintenance Fusion Technology Institute