1 / 31

Measuring Quantum Coherence in the Cooper-Pair Box

Measuring Quantum Coherence in the Cooper-Pair Box. Konrad Lehnert. Depts. of Applied Physics & Physics Yale University. Yale Lafe Spietz Ryan Held Ben Turek Rob Schoelkopf. Chalmers University Kevin Bladh David Gunnarsson Per Delsing. And discussions w/:

Télécharger la présentation

Measuring Quantum Coherence in the Cooper-Pair Box

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Measuring Quantum Coherence in the Cooper-Pair Box Konrad Lehnert Depts. of Applied Physics & Physics Yale University Yale Lafe Spietz Ryan Held Ben Turek Rob Schoelkopf Chalmers University Kevin Bladh David Gunnarsson Per Delsing And discussions w/: M. Devoret, S. Girvin, A. Clerk, K. Nguyen The David and Lucile Packard Foundation Funding:

  2. Can Electrical Circuits be ‘Quantum?’ Macroscopic Quantum Coherence: Cooper-pair boxY. Nakamura et al, Nature 1999 • New Challenges: • Understand and minimize decoherence • Develop efficient quantum readout • New Opportunities: • Create artificial atoms • Quantum computation

  3. Quantum Circuits for Quantum Computing Quantum bit (or “qubit”) Classical bit Information as state of a two-level quantum system , or values values 0 or 1 superposition: Prediction: a 2,000 bit quantum computer = a conventional computer the size of universe.

  4. Quantum Computing Ion TrapsLiquid State NMR Nuclear Spins inSemiconductors Coherent Scalable ControllableMeasurable Cooper-pair boxSQUID’s How coherent is a Cooper-pair box?

  5. Single Electron Transistor Measuring Box Vds Box SET Electrometer Cg Cc Cge Box Vg Vge SET Superconducting tunnel junction Al/AlOx/Al junctions; 50 x 50 nm e-beam lithography; double-angle evaporationTc ~ 1.5 K

  6. Cooper-pair Box Vg Vg

  7. Cooper-pair Box as Quasi-spin 1/2 Measure charge Ground state 1 b c a a b c Excited state 0 0.5 E a b c

  8. NMR of a Single Spin Single Spin ½ Quantum Measurement Vds Cgb Cc Cge Box Vgb Vge SET

  9. Single-electron Transistor: Electrometer SET drain Vds Cge Vge Ids 10 nA source Electrometer input gate Vds 1 mV

  10. Radio-Frequency Single Electron Transistor (RF-SET) Response to step in Vge Transformer SET single time trace RF Reflected power Electrometer input gate Measure RF power reflected from LC transformer 10-5 e/Hz1/2 charge noise Sub-electron sensitivity for > 100 MHz bandwidth Schoelkopf et al., (Science 1998)

  11. Small, Cold and Fast Microwaves Dilution refrigerator T = 15 mK 1 mm Millikelvins Nanometers

  12. Experiment Diagram

  13. Continuous Measurement of a Single Spin Measured continuously by SET Theory: Cooper-pair box ground state 1 0.5 2e 1e 0 0 0.5 1 Measurement must cause additional dephasinguncertainty principle Measurement mayalso mix states, drive transitions from ground state

  14. Cooper-Pair Resonance Spectroscopy E Cg Vapp 38 GHz Vapp=Vg+Vacsinwt 1 w/2p=38 GHz 0 0 0.5 1

  15. Determination of Box Hamiltonian “SQUID box” to vary EJ Peak location 32 GHz 0.29 Vapp B 35 GHz 38 GHz 0.25 0 -2 2 -1 1 Fit parameters: E

  16. Saturation of the Cooper Pair Resonance Photon Peak Height 0.5 37 GHz 39 GHz 0.2 0 0.235 0.265 Peak width Peak height 50% saturated 0

  17. Excited-state Lifetime 0 t<0 t>0 0.15 e time t=20ms 0 10 ms 1e 0.3e t=1.6 ms t<0 t=0.4 ms Peak height (e) 0 0.5 1 time 0 10 ms

  18. Spontaneous Emission Environment SET Box Vds Cc Cg Vg 2e SET E Relaxation

  19. Spontaneous Emission into Environment Spontaneous Emission:Fermi’s golden rule Cg Box Vg 2e

  20. Electrometer Input Impedance Cg Cc Cg Cc Vg 2e 2e 2e SET 0.6 185 W Peak Height (e) 0.3 370 740 0 Electrometer Operating Point (Vg)

  21. Conclusions • Cooper-pair Box: A quantum two-level system worst-case coherence • Box Hamiltonian determined with spectroscopy • Long excited-state lifetime while continuously measured. • Box measures electrometer input impedance

  22. Box State Depends on Electrometer Bias Vds (mV) 0 250 290 420 470 760 1200

  23. Conclusions • RF-SET measures charge states of box • Spectroscopic determination of Hamiltonian of box • Dephasing time ~ 1 ns : (w/ continuous measurement) • Long Excited-state lifetime >1 ms : • Electrometer affects T1

  24. Outline • Charge quantization on a normal-metal island Single-electron Box • Superconducting island as quantum two-level system Cooper-pair Box • Spectroscopy of the Cooper-pair box Single-electron Tranistor (SET) measures box • Box Measures SET Quantum Spectrum Analyzer

  25. The Single-Electron Box island Cg Vg ne e Cj Rj Normal tunnel junction E Ec ne to ne+1 electrons Ec/4 ne=-1 ne=0 ne=1

  26. Single-electron Box: Coulomb Staircase E First demonstrated by Lafarge et al, ’91(Saclay) Ec Ec/4 ne=-1 ne=0 ne=1 200 mK 16 mK Coulomb Staircase Thermally broadened 1 e e 0 kT/Ec -1 -1 -0.5 0 0.5 1

  27. Cooper-pair Box Spectrum: Electrostatic and Josephson E EJ Ec n=-1 n=1 n=0 Condition:Two level System EJ /4Ec 2e 2e -0.5 0 0.5

  28. Cooper-pair Box as Spin 1/2 Time scales w01 Larmor frequency 10-40 GHz T1 Excited state lifetime 0.1-10 ms WR Rabi frequency T2* Ensemble decoherence time

  29. Vbias Cmeas ? The Quantum Spectrum Analyzer 0 Measures all NoiseClassical (symmetric) Quantum (asymmetric)

  30. Cooper-pair Box Spectrum: Electrostatic and Quasi-particle E n=1.5 n=-0.5 n=0.5 Ec n=0 n=1 n=-1 Odd: single q.p. Even: no q.p. kT/4Ec 2e 2e-periodic Cooper-pair Staircase 2e -0.5 0 0.5

  31. Cooper-Pair Resonance Spectroscopy E Cg Vapp Vapp=Vg+Vacsinwt 1 38 GHz 35 GHz 0 0 0.5 1