Expert Name for BLM - All Except Dump 1, 2, 3, 4
40 likes | 123 Vues
Comprehensive guide detailing element positions, types, and locations for Beam Loss Monitors in different setups. Includes observations for various elements like quads, dipoles, kickers, BPMs, and more.
Expert Name for BLM - All Except Dump 1, 2, 3, 4
E N D
Presentation Transcript
Expert Name for all BLM except Dump 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17+Official name => upto 30 BLMQI.06R7.B1E30_MQMxxx(_S) BLM location: Q for on a quad E for other location 2for coupled monitors Observed element Position on the element: 10 at the entrance 20 or 2x at the middle 30 at exit BLM type: I for IC S for SEM Cell and sector position: 01-34 number of cell R or L from IP 1-8 IP Transverse position: E for external I for internal _S added for second coupled monitor counting in beam direction • Beam 1 or beam 2 observed
Observed element names for quads (BLMQI or BLM2I) 1) Observed element names for main and insertion quadrupoles: MQM, MQY, MQ, MQML, MQTL 2)Warm quadrupole: MQWB.4R7 or MQWA.B4R7 3) One IC which observed 2 elements:quad and XRP: 1. BLMQI.04L5.B2E10_MQY_XRP, 2. BLMQI.06R5.B1E10_MQML_XRP 3. BLMQI.06L5.B2E21_MQML_XRP 4)Coupled quads monitors, when the second monitor names are with _S: 1. BLM2I.10L3.B2E30_MQ_MQ_S 2. BLM2I.10R3.B1I30_MQ_MQ_S 3. BLM2I.09L3.B2E30_MQ_MQ_S 4. BLM2I.09R3.B1I30_MQ_MQ_S
Observed element namesfor Dipoles, Collimators, Beam Absorber, Injection and Ejection dump kickers, Injection and Ejection dump septums, BPM, XRP and so on(BLMEI or BLM2I) • Dipoles: BLMEI.08R1.B1E30_MBA BLMEI.06R7.B2I10_MBW.A6R7 BLMEI.01L2.B1I10_MBWMD BLM2I.04R8.B1I10_MBRC_MBRC_S • XRP: BLMEI.04L5.B2E10_XRP • BPM: BLMES.01L1.B1I10_BPMSW.1L1 • Septums: BLMEI.06R8.B2E10_MSIA, BLMEI.06R8.B2E10_MSIB • Kickers: BLMEI.05L2.B1E10_MKI.D5L2.B1 • Collimators: BLMEI.04R7.B1E10_TCSG.B4R7.B1 • Connections: BLMEI.05L6.B2I10_LEJL
Expert Name for BLM at Dump 1)BLMDI.623243.D2I1_MKBH or BLMDI.683780.D1T1_MQY.4R6 BLMPS.683545.B1E1_TCDQA.4R6.B DorP – dump or direct dump 62 or 68 – TD62 or TD68 xxxx (3243, 3780,…) – distance from the beginning of TD, dm D2 or D1 – dump of beam 1 or beam 2 I,E,T,B,L,R,C – internal, external, top, bottom, left, right, centre transverse position _MKBH – observed element • BLMDI.625880.D2L1_377_203 or BLMDI.686850.D1B1_497_254 _377 – distance from IP, m _203 – change of TD diameter, mm 3)BLMDS.689723.D1C1_3.119_DUMP orBLMDI.629822.D2CT_13.200_DUMP _3.119_DUMP – distance from beginning of DUMP (inside of Core), m T – transversal position for IC which installed out of screen