1 / 6

Harmonic Analysis

Appendix Ten. Harmonic Analysis. Background on Harmonic Analysis. Separation of real and imaginary terms can be performed for not just the force loading but also the response: If the harmonic loading and response are substituted back in the equation of motion, the following is obtained:.

jalfredo
Télécharger la présentation

Harmonic Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Appendix Ten Harmonic Analysis

  2. Background on Harmonic Analysis • Separation of real and imaginary terms can be performed for not just the force loading but also the response: • If the harmonic loading and response are substituted back in the equation of motion, the following is obtained: August 26, 2005 Inventory #002275 A10-2

  3. … Loads and Supports (ANSYS) • Internally, loads are applied slightly differently than in an equivalent static analysis: • Forces on vertices and edges are applied as real & imaginary nodal loads via F,,FX/FY/FZ,REAL,IMAG • Pressures and Forces on surfaces are applied on surface effect elements SURF154 with KEYOPT(11)=2 • For Pressure Load, input is via SF,,PRES,REAL,IMAG • For Force Load on surface, input via SFE,,5,PRES,0 for real and SFE,,5,PRES,2 for imaginary components • Given Displacement Support is via D,,UX/UY/UZ,REAL,IMAG • Acceleration, Bearing, and Moment Loads are used as normal: • Bearing loads are applied as SFE on face 5 of SURF154. Two sets are created for axial and radial components of bearing load: Axial uses KEYOPT(11)=2, Radial uses KEYOPT(11)=0 • Moments on vertices or edges of shells are applied as nodal loads via F,,MX/MY/MZ while moments on surfaces are applied via CONTA174 surface-based constraint (see Ch. 4) August 26, 2005 Inventory #002275 A10-3

  4. … Mode Superposition Method • The previous two equations can be combined and pre-multiplied by the mode shape {fi}T: • Although outside of the scope of the discussion, the above equation reduces to the following: • The resulting equation is uncoupled and is easier to solve • The total degrees of freedom are not dictated by the number of nodes in the mesh. Instead, it is determined by the number of modesn used in the equation. • The equation is simplified because of the following properties: • Normalization of [M]: • Natural frequency wi for mode i: • Damping ratio xi for mode i: August 26, 2005 Inventory #002275 A10-4

  5. … Mode Superposition (ANSYS) • The ANSYS mode superposition method is run internally: • A modal analysis is run first with Block Lanczos eigenvalue extraction method (MODOPT,LANB,200,FREQB/2,2*FREQE) • A maximum of 200 modes between ½ of the beginning frequency FREQB to 2 times the ending frequency FREQE is solved for • A load vector is automatically created at this time • A harmonic analysis using mode superposition method (HROPT,MSUP) is then performed • Frequency range specified with HARFRQ,FREQB,FREQE • If clustering is requested, HROUT,,ON is issued • All loads are step-applied in the frequency range (KBC,1) • Number of intervals (or cluster number) specified with NSUBST • Load vector of 1.0 is issued with LVSCALE,1 • OUTRES with nodal and element components used • An expansion pass is also performed for contour results • EXPASS,ON and HREXP,ALL are used August 26, 2005 Inventory #002275 A10-5

  6. … Full Method (ANSYS) • Internally, the Full method is used in ANSYS: • Frequency range specified with HARFRQ,FREQB,FREQE • HROPT,FULL is used • Number of intervals specified with NSUBST • Loads are step applied in frequency range with KBC,1 • The equation solver is the default sparse solver. The Details view of the Solution branch has no effect on full harmonic analyses, as no solver command (EQSLV) is issued • OUTRES with nodal and element components used August 26, 2005 Inventory #002275 A10-6