1 / 16

HZ Recoil Analysis: Selection & Fitting

HZ Recoil Analysis: Selection & Fitting. LCD WG6 Meeting, 03/04/2012 J.S. Marshall, University of Cambridge. HZ Recoil Analysis - Reminder. Relevant processes for this study are the recoil reaction e + e -  HZ  Hff , commonly called Higgsstrahlung.

jase
Télécharger la présentation

HZ Recoil Analysis: Selection & Fitting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HZ Recoil Analysis:Selection & Fitting LCD WG6 Meeting, 03/04/2012 J.S. Marshall, University of Cambridge

  2. HZ Recoil Analysis - Reminder • Relevant processes for this study are the recoil reaction e+e-HZHff, commonly called Higgsstrahlung. • By detecting decay products of the Z, can search for Higgs signals without further assumption about Higgs decay modes: “model independent analysis”. • For CDR V3, will search for decays Z and Zee: “X” and “eeX” channels. • Signal is selected by identifying two well-measured leptons in final state, yielding Z mass. Can then compute recoil mass: s = 500GeV Lint = 500fb-1 mH= 120GeV No polarization

  3. Requests and Production Status Status on 27/03/2012:

  4. Discriminant Variables • Previously, discussed procedure for finding events with two leptons produced by Z-decay. • Events passing di-lepton selection examined with aim of background rejection in mind. • Know that selection will be rather difficult at s=500GeV and with radiative effects.

  5. Discriminant Variables

  6. Selection - TMVA • Use ROOT TMVA to perform selection. Allows simple cut optimization and comparison of multivariate techniques. • Begin by making a few simple selection cuts to quickly veto background whilst leaving signal largely unharmed. • Use TMVA to suggest a series of cuts, choosing to use those that approximate to 90% signal efficiency for X. Cuts for 90% signal efficiency Pass Di-Lepton ID 30 GeV < Mdl < 120 GeVMrecoil < 380 GeVPTdl > 65 GeVacopdl < 2.8DPTBal > -100 GeV

  7. Selection - BDT • Events passing selection cuts given to TMVA for evaluation of different multivariate techniques. • TMVA uses 50% of input events for training and 50% for testing, performing overtraining checks. • Input variables: Mdl, PTdl, cosdl, acoldl, acopdl, DPTBal • Best performance (>20% purity): Boosted Decision Tree

  8. Selection - BDT • BDT also appropriate for signal selection in more difficult eeX channel (but could move to MLP). • Can achieve small improvement with more aggressive initial cuts. However, this can lead to smaller samples for BDT training and hence overtraining. TMVA overtraining report OK: • Application of full selection procedure removes all events from 2-fermion background test samples.

  9. Di-lepton Mass • Choice of BDT cut value currently a little arbitrary: simply try to maintain 30-40% signal efficiency.

  10. Recoil Mass • Will try to fit these distributions to extract mH, nSig, nBkg • Knew selection would be difficult. For comparison, scale results to ILD LoI cross-sections and luminosity. • For ILD LoI analysis, reduced radiative effects also result in better Higgs mass peak. Scale to ILD LoI , L

  11. Kernel Estimation • Need to model signal component of recoil mass distribution. • Take half of selected signal and fit this “reference sample” using Simplified Kernel Estimation. • Signal shape is approximated by sum of many Gaussians, one for each bin in the reference sample. • Transformation x’ = x – mH allows sensitivity to Higgs mass; scaling distribution allows sensitivity to no. of signal events.

  12. Background Fit • Need to model background distribution for any given number of selected background events. • Could just use available MC samples, but ideally want to remove statistical fluctuations. • Choose to fit shape of selected background – 4th order polynomial seems to be OK. • In final fit to recoil mass distribution, won’t vary background position or shape, just normalization.

  13. Predicted Distribution • Using predicted signal and background, can create a prediction for any parameters mH, nSig, nBkg: mH = 120 GeV nSig = 1000 nBkg = 200 mH = 120 GeV nSig = 200 nBkg = 1000 X mH = 50 GeV nSig = 500 nBkg = 1000 mH = 200 GeV nSig = 500 nBkg = 1000

  14. Fit Distribution • To produce input/fit distributions, use remaining half of signal sample, scaled back to 500fb-1. Add background by scaling polynomial fit and introducing Poisson fluctuations. • Creates input distributions shown below. Error-bars reflect fact that both signal and background components derived from high statistics samples (L=25ab-1). • Fit procedure uses MINUIT to vary mH, nSig and nBkg, producing a negative log likelihood value for each comparison of input and predicted distributions:

  15. Results • X sample best fit results: • Trust MINUIT to provide error measurements for each parameter. In the case of mH, 1 shift from best-fit increases negative log likelihood by 0.5 • Will try to further optimize selection (in particular, will try varying BDT cut), but don’t expect to be able to extract parameters with much greater precision.

  16. Results • eeX sample best fit results: • Approach for eeX sample not fully optimized, as have tried to maintain consistency with treatment of X sample. Could introduce differences in selection (currently only BDT training differs).

More Related