SCOTT 4.5 Airpack

SCOTT 4.5 Airpack. Manlius Fire Department Annual SCBA & RIT Pak Familiarization Drill. TERMINAL LEARNING OBJECTIVES.

jessie
Télécharger la présentation

SCOTT 4.5 Airpack

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SCOTT 4.5 Airpack Manlius Fire Department Annual SCBA & RIT Pak Familiarization Drill

  2. TERMINAL LEARNING OBJECTIVES • OBJECTIVE: Given the Scott 4.5 SCBA, firefighters will be able to identify the parts and functions of the SCBA and RIT Pak and use the SCBA and RIT Pak as described in the Scott User Manual • OBJECTIVE: Given the Scott 4.5 SCBA, firefighters will be able to properly donn the SCBA and mask as described in the Scott User Manual. • OBJECTIVE: Given the Scott 4.5 SCBA, firefighters will be able to safely connect the RIC connection as described in the Scott User Manual • OBJECTIVE: Given the Scott 4.5 SCBA and a RIT Pak or another Scott SCBA, firefighters will be able to identify several methods of providing supplemental air to a downed firefighter.

  3. Parts Familiarization

  4. CYLINDER • Carbon fiber • 4500 PSI • Refill at 4000 PSI • “30 Minute” rated, but not really intended to last this long. • Depends on a number of factors.

  5. BACKPACK AND STRAPS • Tri-slide cylinder buckle • Cylinder latch • Kevlar straps • Quick-release parachute buckles • Regulator holder • Inspection • Tears and burns • Chemical exposure

  6. INTEGRATED PASS • “PAK-ALERT SE” • Air activated • Opening cylinder • 3 audible chirps • Green light • Requires 6 AAbatteries • Low battery – single audible chirp every 2 seconds / no green light

  7. INTEGRATED PASS • Manual alarm • Front of PASS • Red button • Full alarm on depression • Auto alarm • Motionless for 20 seconds • Pre-alarm • Ascending / Descending tone • 1 Red light flash /second • Full-alarm • 12 Seconds after pre-alarm • Continuous tones w/ red lights

  8. INTEGRATED PASS • Reset button • Yellow button • Side of PASS • De-activation of full-alarm • Press reset button twice slowly • De-activation of PASS • Turn off cylinder • Vent residual pressure from regulator • Press reset button twice slowly • Two tone chirp

  9. REGULATOR • VIBRALERT alarm • 25% of cylinder pressure • Air actuated vibration • Re-circulates into mask • Air saver/Donning switch • Purge Valve • Integrated HUD

  10. REGULATOR • Inspection • Hose and rubber • Cuts • Tears • Cracking • Quick connect • Dirt • Debris • Cleanliness • Purge valve • Smooth ½ turn

  11. Heads Up Display • After initialization, the rectangular indicator lights will show the level of the air supply in the cylinder as follows: • FULL: 2 green lights glowing near the center of the display • THREE-QUARTERS: single green light glowing. • ONE-HALF: yellow light flashing slowly at once a second. • ONE-QUARTER cylinder end of service time indicator is indicated by the red light at the far left flashing rapidly at ten times a second. • When this warning light is flashing rapidly, the user must leave the hazardous atmosphere immediately.

  12. HEADS-UP DISPLAY (HUD) • Visual display of SCBA air status • Series of lights indicate pressure • Full - 2 green • 75% - 1 green • 50% - 1 yellow slow flashing • 25% - 1 red rapid flashing

  13. How to Don AV 3000 Mask • Adjust the head straps to their full outward position. • Hold the facepiece in one hand and hold the head harness by the strap at the base of the head net. • Place the facepiece on the face with chin properly located in the chin pock­et while pulling the head harness over the top of the head. Verify that no hair or clothing is interfering with the face to facepiece seal. 12 A • Tighten the neck straps by pulling the two lower strap ends toward the rear of the head. • 12 B

  14. Donning mask… • Stroke the head harness net down the back of the head using one or both hands. Verify that the head harness is lying flat against the back of the head. Retighten the neck straps. 12C • Tighten the two temple straps. Adjust the temple straps by pulling the two temple strap ends toward the back of the head. Over-tightening may cause discomfort. 12D • Retighten the neck straps if required.

  15. Attaching Regulator • Fully depress the center of the air saver/donning switch on top of regulator and release. • The breathing regulator is equipped with an air aver/donning switch to prevent the rapid loss of air supply when the cylinder valve is open and the facepiece is removed from the face or the regulator is removed from the facepiece.

  16. Attaching Regulator • If the regulator is not attached to the facepiece, proceed as follows: • Verify that the regulator gasket is not damaged and is in place around the outlet port of the regulator. • Align the two flats of the regulator outlet port with the corre­sponding flats in the facepiece port (the red purge valve on the regulator will be in the 12 o’clock position). insert the regulator into the facepiece port. • Rotate the regulator counterclockwise (as viewed from inside of facepiece) until the red purge valve knob is on the left side of the facepiece. The lock tab on the regulator will lock into the facepiece retainer with a “click.” when the lock tab is properly engaged, the regulator will not rotate.

  17. Attaching Regulator • Slowly open cylinder valve fully by turning the valve knob counterclockwise until it stops (approximately 2 1/2 full turns of the knob).

  18. Attaching Regulator • Observe the operation of the alarms: • The VIB RALERT end of service indicator alarm will actuate and then stop. • The HEADS-UP DI SPLAY shall initialize for twenty (20) seconds and then display the cylinder level. • The PAK ALERT SE 7 distress alarm will actuate when the cylinder valve is opened and will sound three quick audible chirps accompanied by a green flashing on the PAK ALERT SE 7 control console

  19. Attaching Regulator • If the air saver/donning switch has not been depressed prior to opening the cylinder valve, the VIB RALERT Alarm will not actuate due to the air flowing freely on the facepiece. • With facepiece sealed to face, inhale sharply.

  20. Always check the facepiece seal, the system seal, and the operation of the end of service alarms using the following procedure: • Completely close the cylinder valve by pushing in on the cylinder valve and rotating it clockwise. • Breathe on respirator. As the air pressure falls in the respirator, one or more of the end of service indicator alarms will actuate. • Immediately on actuation of any end of service indicator alarm, hold breath momentarily and make certain that the Vibralert and heads up display both actuate (rapid clicking of the Vibralert Alarm, rapid flashing of the heads up display red light.

  21. Resume breathing on the respirator until all air stops flowing from the breathing regulator. • NEGATIVE PRESSURE LEAK TEST: Inhale slowly and hold breath momentarily. No leakage of air shall be detected into the facepiece and the facepiece shall be drawn slightly to the face. • Open cylinder valve and breathe normally. If installed, the electronic end of service time indicator will continue briefly then stop.

  22. Use in Standby mode • The respirator may be donned and worn in "Standby," so that it is ready for use. This means the respirator is in place on the user’s body with the shoulder straps properly adjusted and the waist belt buckled, but the facepiece is not donned (sealed to the face) and the respirator is not being used.

  23. Leave the cylinder valve fully open and verify that the air saver/donning switch is depressed. • Remove the facepiece but leave the regulator attached to the facepiece. • Keep the facepiece ready for use either of two ways: • Hang the facepiece from the snap clip on the left shoulder pad, • Hang the facepiece from the optional neck strap. • NOTE DO NOT LET THE FACEPIECE HANG LOOSE WI THOUT SECURING ITAS NOTED ABOVE.

  24. The regulator can be detached from the facepiece until needed. To detach the regulator from the facepiece: • Place your right hand over the cover with your thumb on the lock tab. • Pull the lock tab toward the cover and rotate the regulator ¼ turn clockwise (viewed from inside of facepiece). • W hen the red purge valve is in the 12 o’clock position remove regulator from the facepiece. • The regulator can be stored in the optional regulator holder on the waist belt.

  25. EBSS – DUAL MANIFOLD • EBSS – Emergency Breathing Support System • Introduction of air from outside source • Ladder air system • RIT Bag • Another SCBA (buddy breathing) • On left side waist belt • In snap pouch

  26. EBSS – DUAL MANIFOLD • Male and Female coupling • Quick disconnect • Supply or receive • 3 foot hose • Dual protective cover

  27. EBSS – DUAL MANIFOLD • Extended Duration air supply (aerial ops) • Use male coupling • Operates as open-circuit, pressure demand • Emergency Breathing (Buddy breathing) • Used for escape only • Utilizes highest pressure bottle • One bottle can be turned off to conserve air • Can “Daisy-Chain” up to 3 users • Will not provide enough air for >3

  28. RIC UAC – RAPID INTERVENTION UNIVERSAL AIR CONNECTION • FOR EMERGENCY USE ONLY! • Permits emergency replenishment of air • Not a quick charge

  29. WARNING!!! Utilizing RIC UAC for emergency air replenishment of a structurally compromised cylinder will result in an over pressurization explosion.

  30. SCOTT RIT PAK

  31. SCOTT RIT PAK 1 • Carbon Fiber 4500 PSI / 60 Min. Cylinder • Cylinder caddy w/ carrying handle • Av-3000Face piece • Regulator w/ quick disconnect

  32. SCOTT RIT PAK 1 • High Pressure hose w/ UAC connection • Pressure reducer block • 5’ low pressure hose and fittings

  33. CYLINDER CADDY • Divided bag • Cylinder storage • Low pressure hose and mask/regulator • Exterior pouch • High pressure UAC

  34. High Pressure Universal Air Connection (“UAC”) FOR EMERGENCY USE ONLY!!!

  35. RIC Connection

  36. HIGH PRESSURE UAC • 5’ high pressure hose • Side Pocket of Pack • Air directly from bottle • UAC – Universal Air Connection w/ cap

  37. RIC UAC – RAPID INTERVENTION UNIVERSAL AIR CONNECTION • Permits emergency replenishment of air • Not a quick charge • Within 6” of neck of bottle on all NFPA 1981 (2002) compliant SCBA’s

  38. OPERATION OF UAC • Ensure RIT cylinder valve is fully open • Extend high pressure UAC hose • Remove protective cap • Ensure SCBA cylinder valve is fully open

  39. OPERATION OF UAC • Locate UAC on receiving SCBA • Remove protective cap • Align and push – UAC will self-lock • Connection will self lock • Cylinder pressures will equalize

  40. TERMINATION OF UAC • Pull back UAC collar and pull UAC from SCBA • Turn off RIT cylinder • Replace protective cap • Press center of cap to vent residual pressure

  41. TERMINATION OF UAC WARNING!!! DO NOT attempt to vent pressure without cap on. This will inject high pressure air into skin.

  42. LOW PRESSURE HOSE • 5’ HOSE • 2 Connections • EBSS – Air from highest pressure cylinder • Schrader • Double male adapter for female EBSS • AV-3000 face piece • Same mask as issue • Regulator • Quick disconnect

  43. OPERATION OF LOW PRESSURE HOSE • Examples of when RIT low pressure hose should be used • FF low on air • Failure of mask • Failure of regulator • Failure of SCBA • Structural compromise of cylinder

  44. OPERATION OF LOW PRESSURE HOSE • Multiple Options • EBSS to EBSS • EBSS to regulator • EBSS and regulator to mask • EBSS, regulator and mask • Rescue operations

  45. OPERATION OF LOW PRESSURE HOSE • EBSS to EBSS • Align EBSS and push • Coupling self locks • Air from highest pressure cylinder • Can turn off SCBA cylinder to conserve air • Will not hot charge SCBA

  46. OPERATION OF LOW PRESSURE HOSE • EBSS to regulator • Turn on RIT cylinder • Disconnect coupling from SCBA • Align coupling with EBSS and push

  47. OPERATION OF LOW PRESSURE HOSE • EBSS and regulator to mask • Align coupling with EBSS and push • Turn on RIT cylinder • Remove regulator from SCBA • Replace with RIT regulator

  48. OPERATION OF LOW PRESSURE HOSE • EBSS, regulator and mask • Align coupling with EBSS and push • No electrical connection • No HUD • Turn on RIT cylinder • Remove regulator and mask from FF • Replace with RIT regulator and mask