160 likes | 747 Vues
Water Quality. Lecture 13: Introduction to Environmental Engineering. Measures of Water Quality. What is clean water? Is D.C.’s drinking water clean? What are some parameters that determine water quality? Dissolved oxygen – oxygen probe and oxygen meter Biochemical Oxygen Demand Solids
E N D
Water Quality Lecture 13: Introduction to Environmental Engineering
Measures of Water Quality • What is clean water? • Is D.C.’s drinking water clean? • What are some parameters that determine water quality? • Dissolved oxygen – oxygen probe and oxygen meter • Biochemical Oxygen Demand • Solids • Nitrogen – ammonia • Bacteriological quality
Biochemical Oxygen Demand • BOD • Measurement of the rate at which microbes degrading organic matter use oxygen • One can calculate the theoretical oxygen demand • If you know the chemical formula – • for example 1.67 x 10-3 M glucose • C6H12O6 + 6O2 6CO2 + 6H2O • 6 x 1.67moles/L x 32 g/mole x 1000 mg/g = 321 mg/L • BOD is used because wastewater isn’t one organic molecule
Biochemical Oxygen Demand • Standard BOD Test • Run in the absence of light (algae) • @ 20C for 5 days, defined as BOD5 • Standard 300 mL volume BOD bottle • BOD ultimate, L, BOD greater than 20 days • BOD = I –F I = initial DO, mg/L F = final DO, mg/L
Biochemical Oxygen Demand • What if the F is =0? • Dilution of the sample is required when F = 0. If F = 0 we don’t know how much DO would have been used. BOD = (I – F)D D = dilution
Biochemical Oxygen Demand • Dilution by how much? • The proper dilution amount is rarely known before the test. • A proper BOD test requires a change of DO of 2 mg/L • And more than 2 mg/L remaining at the end of the test • The dilution required is calculated as:
Biochemical Oxygen Demand • Seeding • The addition of active microorganisms that take up oxygen • May be required in samples that do not have their own • If seeding is necessary, any BOD that is contributed by the seed must be subtracted
Biochemical Oxygen Demand • BOD with dilution and seed • BODt = BOD at time t, mg/L • I, F = initial and final DO of sample and seed, mg/L • I’, F’ = initial and final DO of seed water, mg/L • X = seeded dilution water in sample bottle, mL • Y = seeded dilution in bottle with only seed dilution water mL • D = dilution of sample
Biochemical Oxygen Demand • Example • Standard BOD test with a 1:30 dilution with seeded dilution water is run. Both bottles begin at saturation, 9.2 mg/L. After five days, the bottle with waste has a DO of 2 mg/L, while the DO of the seed = 8 mg/L. Find the BOD5.
Biochemical Oxygen Demand • Typical BOD values • Wastewater BOD5 250 mg/L • Effluent BOD5 from wastewater < 30 mg/L • Industrial wastewater = 30,000 mg/L • US Engineers often speak in terms of lbs BOD5/day • Mass rate load of a plant to the receiving stream
Biochemical Oxygen Demand • The BOD test occurs in a bottle, • Thus the mass balance is Rate of DO accum. = rate of DO consumed dz/dt = -r z = dissolved oxygen, mg/L Assume that it is a first-order reaction
Biochemical Oxygen Demand • As O2 is used, the amount still to be used is z, the amount already used is y L = y + z L= ultimate demand
Biochemical Oxygen Demand • Variables • y = BOD at any time t • L = ultimate BOD • k1 = deoxygenation constant • Example • Find the BOD5 for a waste with an ultimate BOD = 282 mg/L and a k1 = 0.348 /day
Nitrogenous Oxygen Demand • Nitrogenous BOD Organic matter + O2 bacteria + NH3 + CO2 + et.al. 2NH3 + 3O2 2NO2- + 2H+ + 2H2O 2NO2- + O2 2 NO3- • Two moles of O2 per mole of NH3 • BODult = a (BOD5) + b(KN) • KN = Kjeldahl nitrogen (measure of organic nitrogen and ammonia) • a and b are constants, a = 1.2 & b = 4.0 for example
Homework • Chapter 8 Problems: 3, 7, 16, 22