1 / 14

Dynamic Radioactive Particle Source - Evaluation of CAM Samplers with Plutonium Aerosols

This report discusses the use of the Dynamic Radioactive Particle Source (DRPS) to evaluate CAM samplers with plutonium aerosols. The DRPS provides a cost-effective and non-contaminating solution to replicate the presence of a plutonium aerosol cloud, allowing for iterative development and evaluation of CAMs.

jonny
Télécharger la présentation

Dynamic Radioactive Particle Source - Evaluation of CAM Samplers with Plutonium Aerosols

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dynamic Radioactive Particle SourceLos Alamos Unclassified Report 09-02686US Patent Office Application #12433503 Murray E. Moore Alan L. Justus Los Alamos National Laboratory Radiation Protection Group RP-2 Adam B. Gauss Ares Corp., Los Alamos NM Air Monitoring Users Group – May 4, 2009

  2. Dynamic Alpha Particle Source Problem: ** Evaluation of CAM samplers with plutonium aerosols ** Time intensive, expensive, requires special facility. Solution: ** Dynamic Radioactive Particle Source (DRPS) ** Replicates the presence of a plutonium aerosol cloud.

  3. Dynamic Alpha Particle Source Designed to dynamically introduce radioactivity, with the appropriate alpha spectrum.

  4. Dynamic Alpha Particle Source Current Evaluation Techniques • Check Source • Pu-239 Aerosol Generation

  5. DRPS Puff Release - Integrated

  6. DRPS geometry for replication of a puff release

  7. DRPS geometry for replication of a chronic release

  8. DRPS Chronic release replication

  9. DRPS chronic release with actual CAM response

  10. DRPS mounted in a Canberra filter cartridge

  11. Dynamic Alpha Particle Source • Provides non-specialized in-house testing • Low cost: ~$2,000 (Pu aerosol ~$10,000 per test) • Control of CAM for multiple test scenarios • Repeatability • Simulation of realistic plutonium aerosol spectrum • Supports iterative development/evaluation of CAMs • Adaptable for use in a number of different CAMs • Does not contaminate tested CAM sampler

  12. Dynamic Alpha Particle Source Questions?

  13. Murray E. Moore Alan L. Justus Los Alamos National Laboratory Radiation Protection Group RP-2 Adam B. Gauss Ares Corp., Los Alamos NM Air Monitoring Users Group – May 4, 2009 Dynamic Radioactive Particle SourceLos Alamos Unclassified Report 09-02686US Patent Office Application #12433503 Unclassified LA-UR-09-02686