1 / 39

Air purification tech that pays

cost efficient. c limate smart. healthy. Air purification tech that pays. Clean Air indoors. A sound living environment is:. healthy. c limate smart. c ost efficient. Our air purification technology contributes to a sound living environment. hälsosam. Clean Air?.

kael
Télécharger la présentation

Air purification tech that pays

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. costefficient climate smart healthy Air purificationtechthatpays

  2. Clean Air indoors A sound livingenvironment is: healthy climate smart costefficient Our air purificationtechnology contributesto a sound livingenvironment

  3. hälsosam Clean Air? Carbondioxide0,04% Argon 0,93% Oxygen 20,95% Nitrogen 78,08% + small buthealthaffectingamountsof particles, gasesoch microbes…

  4. healthy 1 nm 10 nm 100 nm 1 m 10 m 100 m size DUST SMOKE, SOOT, ASHES… VIRUS BACTERIA SOLVENTS POLLENS VOC, GASES WARNING:Capture by lungs! Air Ionic air purificationtechnology Conventional filters Clean Air?

  5. healthy Clean Air? Tiredness Irritatedbreathing/eyes Allergies Asthma Illness Small particles Organiccompounds Chemicals Bacteriae Virus Spores

  6. healthy Clean Air! Alertness Zeal Bettersleep Improvedhealth Small particles Organiccompounds Chemicals Bacteriae Virus Spores

  7. climate smart Climate Smart Less CO2 emission Less wasteoflimitedresources Reducedenergyconsumption Reduced dimensions ofventducts and fans

  8. costefficient Reducedenergycosts Less heating Less electricity Less cooling Increasedrecirculationofindoor air Heat exchangers redundant Lowerpressuredrop …and less noisy

  9. costefficient LowerCostofBuilding Reduced investment whenbuilding Smallerventducts No heat exchangers Smaller fans

  10. technology Air Ionization Natural air cleaning process: Rain, waterfalls Shoreline Thunderstorms UV-light Radioactivebackgroundradiation, cosmicradiation Can be replicated: heating, radioactiveradiation, electric discharge…

  11. technology HighvoltageDC Sharp-pointIonization The sharp-pointionizer generates largevolumesofprimaryionswhichattract and combinewithwatermoleculesforming cluster ions.

  12. technology Sharp-pointIonization Oxygen ionsattractwatermolecules, forming cluster (hydrate) ions Cluster ionsattachto and charge small particleswhich in turnattachtoeachother, graduallyforminglargerparticles O2- Highconcentrationofprimary oxygen ions O2-(H2O)n… m… nm…

  13. technology Filtering Particulatematter in the sizerangeofm and largerarecaptured by the filter becauseofsize and electrostatic charge. The filter can be eithera passive PPXTM-filteror an electrostatic filter.

  14. technology DBD Ionization The DBD (dielectricbarrier discharge) ionizer generates a balanced mix of negative and positive primaryions.

  15. technology N2+ O2+ O2- DBD Ionization Properly mixed these cluster ionsinteractto form reactive oxygen species which breaks down many volatile organic and chemicalsubstances and microbs Theseprimaryionsattractwatermolecules, formingvarious cluster (hydrate) ions Highconcentrationof negative and positive primaryions … O2•-, OH-, •OH… H+(H2O)n, O2-(H2O)m… m… nm…

  16. technology An Efficient Combination DBD Ionizer Filter CLEAN AIR Sharp-pointIonizer Control DIRTY AIR Re-circulationofclean air

  17. technology Sharp-pointIonizer Filter DBD Ionizer ( Extra Ionizer ) Ion-/ VOC-sensor Dampers Remote Control via Internet DUC CO2- sensor Recirculation & Control

  18. technology Recirculation & Control

  19. technology It Works! Cleaningefficiency[%] Ionization+ filter Filter Particle diameter [m] Filteringofairborneparticles in different sizes, ref: Indoor Air 2008; 18: 106–112

  20. technology 80 70 60 50 B.Subtilis 40 E.Coli 30 20 10 0 Filter Filter + Ionization It Works! Cleaningefficiency[%] Bacteriae Bakterier: Ref: Indoor Air 2008; 18: 106–112

  21. technology It Works! Example: C10H8 + 12 O2 → 10 CO2 + 4 H2O ”CHEMICAL COMPOUNDS AMENABLE TO TREATMENT BY AIR IONIZATION” Ref: Dr. Stacy L. Daniels: On the Ionization of Air for Removal of Noxious Effluvia, IEEE Transactions on Plasma Science, vol. 30, No. 4, August 2002

  22. technology Dimensioning Addition offresh: 5 l/s (18 m3/h) per person air, (min.)0,35 l/s (1,3 m3/h), per m2 yta Re-circulation: Upto 80% return air CO2levelchecked by sensor Air cleaningcapacity: APS-7: 7000 m3/h (6 DBD-tubes, 12 sharppointbrushes) Ion concentration: 1500 – 3000 ions/cm3(Outdoor air: 300 joner/cm3),

  23. technology ISO 14644 ISO 14644 - - 1 CleanRoomClassification 1 Renrumsklassificering 3 KLASSGR [ No.ofparticles/m3 ] Ä NSER [Antal partiklar/m ] Federal Federal ISO 14644 ISO 14644 - - 1 1 Standard Standard Maximala koncentrationsgr Maximumconcentration limits for particulatematter in sizeslargerthan: ä nser f ö r partiklar lika stora eller st ö rre ä n: 209E 209E m m m m m m m m m m m m 0,1 0,1 m m 0,2 0,2 m m 0,3 0,3 m m 0,5 0,5 m m 1 1 m m 5 5 m m ISO 1 ISO 1 10 10 2 2 ISO 2 ISO 2 100 100 24 24 10 10 4 4 ISO 3 ISO 3 1 000 1 000 237 237 102 102 35 35 8 8 Klass 1 Klass 1 ISO 4 ISO 4 10 000 10 000 2 370 2 370 1 020 1 020 352 352 83 83 Klass 10 Klass 10 ISO 5 ISO 5 100 000 100 000 23 700 23 700 10 200 10 200 3 520 3 520 832 832 29 29 Klass 100 Klass 100 ISO 6 ISO 6 1 000 000 1 000 000 237 000 237 000 102 000 102 000 35 200 35 200 8 320 8 320 293 293 Klass 1000 Klass 1000 ISO 7 ISO 7 352 000 352 000 83 200 83 200 2 930 2 930 Klass 10 000 Klass 10 000 ISO 8 ISO 8 3 520 000 3 520 000 832 000 832 000 29 300 29 300 Klass 100 000 Klass 100 000 ISO 9 ISO 9 35 200 000 35 200 000 8 320 000 8 320 000 293 000 293 000 "Rumsluft" "Rumsluft" Desiredparticle Count?

  24. technology Desired Ion Count? Russian standard: “Requirements for air ions content of housings where PCs and VDTs are used”:

  25. technology Ozone? No, our air purification technologyproduces no* or verylittleozone. Arbetsmiljöverket (Swedish Work Environment Authority): ”The limit valuefor ozoneexposure duringoneworkday (8 hours) is 100 ppb. The limit value for 15 minutesof exposure is 300 ppb.”We’re not evenclose. * Detectablewithadvancedequipmentonly.

  26. technology CarbonDioxide? Not harmfulotherthan in highconcentrationsbutoftenused as an indicatorofotherpollutants Averageconcentration in athmosphere: 400 ppm Limit (as indicator, AFS 2009:2): <1000 ppm Limit (as pollutant, AFS 2005:17): <5000 ppm Security: A CO2-”guard” connectedto a fresh air damperquickliyreduces the CO2-level when the desired limit is reached.

  27. technology Carbon filters? Carbon-/HEPA-filter areefficientbut generate a highpressuredrop, areexpensive and needtoreplacedoften. Ourtechnology is equallyefficient, makes it possibleto re-circulate air and costs far less in the long run.

  28. technology Heat Exchangers? Substantial investment Need a lotofmaintenance in order not toloseefficiency and spreadodour…

  29. applications Applications schools hospitals industry Air Ionic provideefficient solutions for mostneeds… workshops offices livestock farming

  30. products Product Range Air Purification Systems DBD IonizersParticle Separators Air PurificationModulesElectrostatic Filters Stand-Alone Air Cleaners

  31. products APS Air Purification Systems Builtinto new or existent HVAC (ventilation) system Completewithparticle separator, DBD Ionizers, return air damper and control system Scaleable– easyto dimension, install and maintain Dimensionedafterductsize, air quality and air flow: APS-7 < 7000 m3/h APS-14 < 14 000 m3/h APS-21 < 21 000 m3/h APS…

  32. products RJA-6 DBD Ionizer DBD Ionizerfeaturingsixindividuallypowered DBD tubes Usually part of an APS air cleaning system Suitable for an air flowofupto7000 m3/h under normal conditions

  33. products APU-SF Particle Separator Sharp-pointIonizer and filter Depending on application, either PPXTM-filters or elctrostatic filters can be used Usually part of an APS air cleaning system Flexible dimensioning and installation – adaptedafterductsize, air quality and air flow

  34. products APM Air CleaningModule Compact air cleaningmodulesuitable for smaller HVAC systems Completewithparticleseparator and DBD Ionizers Capacity: APM-1: < 200 m3/h APM-2: < 650 m3/h APM-3: < 2000 m3/h

  35. products EFX Electrostatic Filters Electrostatic filters with pre-ionization Module-based system designed toreplaceconventional filters with a minimum of adaptive work May be part of an APS system Suitable for air flows> 500 m3/h

  36. products APU-SA Stand-Alone Air Cleaner Stand-aloneparticle separator Compact and silent Designed for officepremises and similar Maximum capacity:400 m3air/h

  37. summary Simply a great deal:

  38. Thatyou for youtime! Air Ionic AB Krokslätts fabriker 30 SE-431 37 Mölndal Sweden +46 31 706 36 49 www.airionic.se

More Related