1 / 12

Lithium Free-Surface Flow and Wave Experiments

Based on the paper FT/P5-35 for 21st IAEA Fusion Energy Conference 16 - 21 October, Chengdu, China. Lithium Free-Surface Flow and Wave Experiments. H.Horiike 1), H.Kondo 1), H.Nakamura 2), S.Miyamoto 1), N.Yamaoka 1), T.Muroga 3)

kasi
Télécharger la présentation

Lithium Free-Surface Flow and Wave Experiments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Based on the paper FT/P5-35 for 21st IAEA Fusion Energy Conference 16 - 21 October, Chengdu, China Lithium Free-Surface Flow and Wave Experiments H.Horiike 1), H.Kondo 1), H.Nakamura 2), S.Miyamoto 1), N.Yamaoka 1), T.Muroga 3) Graduate School of Engineering, Osaka University, Osaka, Japan2) Japan Atomic Energy Agency, Ibaraki, Japan3National Institute for Fusion Science, Gifu, Japan e-mail : horiike@nucl.eng.osaka-u.ac.jp

  2. Introduction Back Ground IFMIF ( International Fusion Materials Irradiation Facility ) - Liquid Li Target Aim of this study Investigation of the flow dynamics - Surface fluctuation of the target - Measurement technique - Engineering issues Reference from IFMIF Home Page http://insdell.tokai-sc.jaea.go.jp/IFMIFHOME/i_target_en.html

  3. Outline of Osaka Univ. Li Loop Main loop : Test section, Void separation tank, EMP and EMF. The total length : 40 m Daughter loop : Cold Trap, EMP and EMF Free-Surface Test Section Void separation tank 1/2.5 scaled model of IFMIF Li target Dump tank Li Ingot Electro-Magnetic Pump ALIP type EMP < 700 l/min In a pit Li inventory : 420 litter In a pit

  4. Outline of Free-Surface Test Section Nozzle Shima’s model ×2 ( Two convergent sections ) Hight : 10mm, Width : 70mm ( 1/2.5 scale ) made of SS304 Straight Flow Channel Viewing ports Nozzle and Flow Channel Viewing ports and Shutter

  5. Electro-Contact Probe apparatus Fluctuations were measured on Li free surface with using an Electro-Contact Probe apparatus ・ Two needles mechanically fixed move together, but electrically independent ・ Electric motor cylinder to move the needles : 0.1 mm step Set on the second viewing port (on the beam axis) 175 mm from the nozzle needle 1 : 16 mm from the side wall needle 2 : 35 mm (at the center of flow) Electro-Contact Probe Detection circuit

  6. Measured Time Series Signals Probes were moved with 0.1mm step, while recording voltage signals. - Recording time : 20 sec - Sampling freq : 48 kHz ( using PCM recorder) Higher than the Li free surface contacts were rare ( almost no contact) Middle of the surface contacts made frequently Lower than the Li free surface contacts were rare ( almost contact ) No contact • 11.44mm • from wall contact (b) 11.04mm Schematic of contacts (c) 10.74mm at 10 m/s Center of flow

  7. Shapes of Li surface waves Contact frequency and contact time rate were defined and calculated statistically from electric signals Contact frequency : Number of changes between contact and no-contact per unit time Contact time rate : The quotient of total contact period divided by recording time (a) 5m/s (b) 10m/s (c) 15m/s

  8. Average thickness and max wave amplitude Average thickness of the flow Height at maximum contact frequency ( = center of the fluctuation ) - in the lower velocity of 1 to 5 m/s,the thickness shows a peak at ~ 4m/s - in the velocity 5 to 10 m/s, the thickness continuously increased gradually. - in thr velocity of more than 11 m/s, the thickness decreased to 10mm which equals the depth of nozzle throat. Amplitude of the fluctuation defined as half height between “no contact” and “full contact”. - the amplitude increased with flow velocity -in the velocity more than 12 m/s, the amplitude seems to be saturated. - the amplitude was 2 mm at 15 m/s.

  9. Visual observation of the surface Stroboscopic photography of the Li surface at 175mm downstream from the nozzle exit (second viewing port) (a) 2 m/s (b) 3 m/s (c) 5 m/s (d) 7 m/s (e) 10 m/s (f) 15 m/s

  10. Boundary layer thickness along the nozzle wall and at the nozzle exit Momentum thickness d2along the nozzle was calculated [1] 1. velocity distribution along the nozzle wall ( potential model ) 2. Development of laminar boundary layer ( method of Waltz ) 3. Transition to turbulent ( Re d2 > 420 ) 3. Development of turbulent boundary layer ( method of Buri ) 4. Relaminarization ( acceleration parameter K ) Boundary layer thickness D at the nozzle exit was estimated from the momentum thickness Nozzle coordinate Momentum thickness Transition to turbulent D D [1] K. Itoh et al., “Free-surface shear layer instabilities on a high-speed liquid jet”, Fusion Technol. 37 (2000) 74-88

  11. Non-dimensional amplitude Experimental results of the amplitude was summarized to non-dimensional form, non-dimensional amplitude : A/D against Weber number : We Weber number was defined as where T: surface tension, r: density, U0 : mean velocity The non-dimensional amplitude was well predicted by square of We It is noted that the saturation above We of 5.5 is observed. .

  12. Summary Experiment study on IFMIF liquid Li target was carried out with using a 1/2.5 scale test channel. Surface fluctuation of the target flow was measured by electro-contact probe apparatus. As a result, - Time series signals were represented by contact frequency. - Waves of Gaussian like profiles were observed. - Average thickness of the flow, and maximum amplitude of surface fluctuation were plotted as a function of the velocity. - The amplitude was described by non-dimensional form of We number. This showed that the amplitude was well predicted by square of We number, and it began to saturate above velocity of 12-13m/s.

More Related