First thoughts on BLM’s for the LHC collimator tests in 2004 in SPS and TT40

This article discusses the existing BLM infrastructure in SPS and TT40 and explores what can be learned for the BLM system in the LHC collimator tests. It covers hardware, calibration factors, arc monitors, collimation region monitors, and possibilities for addressing questions on particle flux and shower distribution. The article also highlights the requirements from the BLM system for the collimation test.

kpatrick
Télécharger la présentation

First thoughts on BLM’s for the LHC collimator tests in 2004 in SPS and TT40

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. First thoughts on BLM’s for the LHC collimator tests in 2004 in SPS and TT40 • Existing BLM infrastructure in SPS and TT40 • What can we learn for the LHC BLM system • Hardware • Calibration factors for LHC • Arc monitors • Collimation region monitors • Possibilities to address the questions on particle flux and shower distribution? • What does the collimation test need from the BLM system? • Summary

  2. Existing BLM infrastructure in SPS and TT40 • One monitor installed next to each quadrupole magnet. • Electronics, chambers and supports exist for temporary installation of additional monitors. • Cables for the readout need to be installed during this shut-down. • BUT: • Existing ionization chambers (and electronics) will be saturated by the proposed intensities of 3*1013 protons.

  3. What can we learn for the LHC BLM system? • Tests on BLM hardware, which can be addressed: • Test high flux BLM monitors (SEM’s) if available in time. • Measure the maximum current of the ionization chambers > input to design the protection of the readout electronics. • Uncertainties on the calibrations for arc monitors: • Quench level uncertainty (e.g. different coil configuration for MB, MQ, …) - NO • Estimation of particle flux outside of the cryostats (GEANT simulations for LHC) • Uncertainty from physics model used in simulation - can be addressed in the collimation tests. • Accuracy of geometry - NO • Topology of losses, distance between proton impact location and detector as well as longitudinal distribution of losses - NO

  4. Uncertainties on the calibrations for collimation region monitors: • Cross-talk and background between different collimators and the two beams - NO • Shower distribution (transversal and longitudinal), particle flux (MARS simulations for LHC)- can be addressed in the collimation tests. • According to experts there are about 20% uncertainties on the hadron shower energy deposition at LHC energies.

  5. Possibilities to address the questions on particle flux and shower distribution? • Dedicated test measurements (simple geometry) in TT40 of hadronic shower development at 450 GeV to improve model uncertainties. • Relative flux measurement (transversal and longitudinal shower distribution) in SPS and TT40: Simulations of full geometry of the collimation test set-ups. • Absolute flux measurement (normalized to number of protons on collimator) in TT40 (full beam on collimator front): same as above. • Absolute flux measurement in SPS: Simulation of the collimation factor - particle tracking in SPS with all apertures. What is the achievable accuracy in such simulations?

  6. What are the requirements from the BLM system for the collimation test? • What measurements are foreseen? • > How many detectors? Where? • > What kind of simulations are needed? • Is manpower available for simulations (GEANT, MARS, FLUKA, collimation factor) and analysis?

  7. Summary • Hardware BLM test: • Very useful and feasible • Problems on the flux measurements and simulation cross checks: • Manpower for simulations • Availability of SEM detectors for the flux measurements • MD time sufficient for accurate measurements? • With all constraints and uncertainties: Results versus efforts?

  8. BLM Data from the Collimator tests in SPS and TT40 B. Dehning, F. Ferioli, E.B. Holzer, L. Jensen, L. Ponce and the Collimator Team 26.11.2004 Collimation WG Meeting, CERN E. B. Holzer

  9. SPS BA5 E. B. Holzer

  10. 8 Ionization Chambers E. B. Holzer

  11. E. B. Holzer

  12. E. B. Holzer

  13. B B D D Left out Right in C A Left in / Right in Smaller gap Left in Right in Left in / Right out C A E. B. Holzer

  14. Left in / Right out B D Left in Right in Smaller gap C B D Left in Right in C A Left out / Right in A E. B. Holzer

  15. E. B. Holzer

  16. Activation? Factor 5000 reduction in signal after 4 seconds t [s] E. B. Holzer

  17. Activation measurements in the SPS • Lit: G. Ferioli, R.L. Keizer, Analysys of the induced radioactivity in the SPS extraction channels during 1994, SL/Note 95-06 (BT) • Ionisation chamber based measurements during the fast extraction (SPS LSS6) and after to determine the remaining activation • Location of monitors: near kicker magnets and septum's • Ratio between fluence of losses and activation 2000 E. B. Holzer

  18. Decay constants • Two decay constants • t1: 1.75 s • t2: 278 s E. B. Holzer

  19. TT40 E. B. Holzer

  20. BLM5 BLM3 BLM2 BLM1 BLM4 • BLM1 – BLM4: ionization chambers • BLM5: SEM (no calibration) E. B. Holzer

  21. Number of electron pairs produced (35 eV) per litre by 4X72 bunches, at floor level. Scale in cm. From M. Magistris. Signal for 4 batches: E. B. Holzer

  22. BLM signal # protons 1 - 4 Batches on both Collimator Jaws and the TED Collimator TED BLM signal # protons E. B. Holzer

  23. Scanning the Impact Position on the Jaws BLM signal / # protons Distance from surface [mm] BLM signal Distance from surface [mm] E. B. Holzer

  24. Summary • No activation observed (Signal decreases by at least a factor 5000 when collimator moves out). • “Tails” in distributions are from the beam. • BLM signal is linear with proton intensity. • Left-right asymmetry of the shower depends on the collimator gap size and gap position. • Slight top-bottom asymmetry? • BLM signal depends on the impact position on the jaw. • Compares ~ OK with simulations (TT40). • Further analysis … E. B. Holzer