PS 2: Question 6 How do the first IEC61850-based technical solution differ?

Connection to Plant bus. PS 2: Question 6 How do the first IEC61850-based technical solution differ?. The first running substations are turnkey projects. Typical system. Example: Garzweiler II

Télécharger la présentation

PS 2: Question 6 How do the first IEC61850-based technical solution differ?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Connection to Plant bus PS 2: Question 6How do the first IEC61850-based technical solution differ? • The first running substations are turnkey projects. Typical system Example: Garzweiler II • Station bus for three voltage levels:110kV – Section (HSA) 25/6 kV- Section (HSA) 6kV – Section (BSP) • Over 140 Protection and Bay Units.7SJ63, 7SJ64, 6MD66 and 7SJ62: IEC61850 7UT6: IEC60870-5-103 • Connection to tap-change and Petersen-coil regulator using IEC61850 • High Availability due to automatic ring management using intelligent switch modules general indications Station bus IEC61850 FO-Ring with ring management Serial Hub Connection toBay Units usingIEC61850 Connection toBay units using IEC60870-5-103 Switchgear IEC61850 - RJ45 IEC61850 – optical fiber

  2. Control Centre Pilot project: RWE Rheinbraun – Garzweiler II – Control room remote HMI (Net Meeting) • SICAM PAS-System, consisting of: Full server 2xDIP (Device Interface Processor) SICAM PAS CC remote Control PC Mobile Control PC • Bay controller via IEC61850 IEC 60870-5-103 • Substation connection IEC60870-5-101 • Control center connection IEC 60870-5-101 • Notebook as mobile Control PC useful at every switch. local HMISICAM PASCC IEC60870-5-101 SICAM PAS FS DIP 10 km DIP Transformer monitoring 4 times IEC 101 IEC61850 bus FO-Ring with ring management Connection Station bus110kV HSA Connection Station bus6kV BSP Connection to Station bus25/6kV HSA MobileControl-PC IEC61850 - RJ45 IEC61850 – optical fiber IEC 60870-5-xxx- Cu

  3. Pilot project: VW SalzgitterControl room local HMI SICAM PAS CC IEC61850 / IEC60870-5-103 Hall 1 IEC 61850 IEC 103/ RS485 SICAM PAS 1 … 5 Switchgear Hall 2 Connection to Corporate Network Hall 3 Hall 4 generalstation indications Central heating Ethernet TCP/IP IEC61850 / IEC60870-5-103 Station bus to production sections IEC61850 - RJ45 IEC61850 – optical fiber IEC 60870-5-103- Cu

  4. Pilot project: VW Salzgitter- 20 kV switchgear Switchgear 20kV 3 sections with 12 feeders each Bay Units 6MD63/7SJ63 using IEC 61850 Protection Units 7SD61 using IEC 103 Due to short distances, a RS485 copper connection is used Connection to plant busapprox. 20 m Station bus IEC61850twisted-pair cable ring IEC61850 SerialHub IEC 103/ RS485 1 … 12 Switchgear Section 1 section 2 section 3 IEC61850 - RJ45 IEC61850 – optical fiber IEC 60870-5-103- Cu