1 / 5

Result of GAS analyses

Result of GAS analyses. 2003 Feb. 25 T.Tsuboyama (KEK). Method. The helium gas was introduced to a glass tube filled with water. About 200 liter of Helium gas (half of the tank volume) was processed.

lalo
Télécharger la présentation

Result of GAS analyses

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Result of GAS analyses 2003 Feb. 25 T.Tsuboyama (KEK)

  2. Method • The helium gas was introduced to a glass tube filled with water. • About 200 liter of Helium gas (half of the tank volume) was processed. • An ion-chromatography analysis was applied to the water. (Ions are separated by using ion-exchange plastic column). The sensitivity is O(ppm).

  3. Result • Inorganic ions were NOT found • F-, Cl -, SO3-, SO42-, NOX … • Organic acid base (-COOH?) was found. • It may come from grease of compressor/motor. • 100 ppm in the water (<10 ppm in the gas) • Charcoal filter has been installed. The puropse is to absorb organic residuals. • Another sampling will be scheduled.

  4. Analysis of the powder • A fluorescent X-ray analysis was applied. • More or less consistent with IHI analysis. • Large amount of Be, Al and O was found. • Other elements were not significant. • In order to separate Be(OH)2 from BeO, an X-ray diffraction analysis is necessary. • However, the amount of power is not enough.

  5. Paraffin analysis • Shimadu techno research is doing the analyses. • Detection of sulfur and chlorine in old is not of a standard procedure. • They do not guarantee <10 ppm sensitivity. • Result will come late this week.

More Related