Fiber Optics Division. ONMS Optical Network Monitoring System Monitors dark or active fibers in network Integrates to Customer NOC/NMA Alarm / notification / dispatch. Fiber Optics Division Product Portfolio. OMK-55 Power Meter OLP-55 Optical Source OLS-55 Optical Attenuator OLA-55.

lilac
Télécharger la présentation

Fiber Optics Division

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fiber OpticsDivision

  2. ONMS Optical Network Monitoring System • Monitors dark or active fibers in network • Integrates to Customer NOC/NMA • Alarm / notification / dispatch Fiber Optics DivisionProduct Portfolio • OMK-55 • Power Meter OLP-55 • Optical Source OLS-55 • Optical Attenuator OLA-55 • MTS-8000 • All on one • OTDR/CD/PMD/WDM • PDH/SDH/Ethernet • Fault locator mode • Hi-vis color screen • Touchscreen • Smart Handheld Optical Meters OLP-57 & OLT-55 • 1310/1490/1550nm • OLP-57 selective 1310/1490/1550nm w/ thru-mode for upstream 1310nm λ • USB port for results download • MTS-5100/6000 (OTDR) • 1310/1550nm PON module • Fault locator mode • Hi-vis color screen • OLX-6 Pocket Size Optical Meters • OLS-6 Source 1490nm version available • OLP-6 Pwr Meter 1310/1490/1550 • ORL-55 • Return Loss Meter • Power Meter • Optical Source

  3. The SMART Design Protection cap cannot get lost Universal 2014 adapters for power meter´s best accuracy Stand Universal 2150 adapters for all 2.5mm and 1.25mm connector types Graphical display 64 x 128 dots USB interface 12V DC power supply Clear, menu structured operation Easy user interface SMARTStar High battery capacity for long operation time4 x AA Shock proofed housing

  4. SMART Features & Benefits Accessories MT-1S MT-2S MT-3S MK-3S SNT-121Aworldwide compatibel power supply 12V car adapter OVF-1 OCK-10 Cleaning kit Optical adapters 2014 Optical adapters 2150 Optical fiber cables: singlemode, multimode, PC, APC

  5. SMART Features & Benefits OLT-55 • Simultanously measurement with up to 3 wavelength(FFT algorithm) • High dynamic range: 60dB • Three in one instrument • Loss Test set • Power meter mode • Laser source mode • Universal adapter system • Structured data memory (cable/fiber) for > 1000 records • Fast operation: AutoZeroing, Twintest, Tripletest

  6. SMART Features & Benefits ORL-55 • Simultaneously measurement with up to 3 wavelength(FFT algorithm) • High dynamic range: 60dB • Angled test port for lowest intrinsic error • Only “OPEN” calibration necessary • Three in one instrument • Return Loss Meter • Power meter mode (reduced specs due to fiber coupling) • Laser source mode • Universal adapter system with APC test port • Structured data memory (cable/fiber) for > 1000 records • Fast operation: AutoZeroing, Twintest, Tripletest

  7. Optical Measurement PlatformOTDR/PMD/CD/OSA/LTS/PDH/SDH/Ethernet…… MTS-5100 MTS-8000 MTS-6000

  8. MTS-6000 Field Mini OTDR Removeable LiIon Battery Microphone • 5 Hardkeys and 1 Start/Stop key • For easy page selection. • No Pop up menus 7 Softkeys - Context dependent - SW Compatibility with MTS/TBERD 8000 Navigation Pad 4 Molded Bumpers • 8.4" High Visibility TFT Color Screen • - Ideal landscape format for OTDR results • For both inside or outside use • Touchscreen on option

  9. MTS-6000Advanced Field Modularity LiIon intelligent battery with extended life time - 8 hours with Telcordia Standard for OTDR More than 40 optical modules available! (All MTS/TB 8000 compatible) • OTDR MM • OTDR SM (From FTTx to long haul networks) • OFI • CD • PMD • WDM One extractible optical module

  10. Test and Data Interfaces Standard Electrical Interfaces Optical Options MTS/TB 8000 adds: • Compact Flash • VGA output • DIN connector • Modem • Talk-Set /Light Source • Data transfer • - Remote control • RJ-45 Ethernet Port • Remote control • FTP transfer… AC Input Headset • 2 x USB Ports • USB memory sticks • Video inspection probe • Mouse, keyboard… Power-Meter VFL

  11. Connection check Application: Verify the quality and integrity of optical distribution frame and fiber jumpers • VFL • Patchcords analysis • Power Meter • Patchcord loss/launch fiber • Videoscope • Connector quality analysis (OTDR, patchcords, link…)

  12. Main OTDR Specifications • Best in industry data acquisition speeds (<0.1 seconds) • Industry leader for dynamic range with 50dB @ 1550nm (UHD) • New wavelengths and combinations available: • 1490nm for FTTx, • 1383nm for CWDM • Filtered 1625nm for “In-Service” measurements • 1310/1490/1550 for FTTx • 1310/1383/1550/1625nm for CWDM

  13. Installation and Cable Acceptance OTDR Mesurement • Multi-wavelength acquisition • Setting of events • Trace + event table • Marker mode • Manual mode Bi-directional OTDR • Splice measurement and average calculation • Limits handling errors by exchanging configuration. • Link continuity checking • Immediate trace alignment

  14. Other Applications: • Chromatic dispersion • PMD • CWDM/DWDM maintenance • Attenuation profile Ready for very high bitrates • Dispersion measurements approved and standardized by ITU, IEC et EIA/TIA • Spectral attenuation combined to PMD test module

  15. Options/Accessories • Accessories • Options (At time of purchase) • Video Fiber Scope • Additional intelligent battery • Keyboard, mouse, USB stick • PC application Software (FiberTrace and FiberCable) • 2 soft carrying cases • 1 hard carrying case • Cigarette lighter power adapter • Additional optical adapters • Optical test cables • Calibration report • Touchscreen • Extended internal memory • Power meter • VFL • Talkset/Sources

  16. MTS 8000 – Platform Introduction Next Generation Test Platform!!

  17. MTS 8000 Modular Architecture Transport Module one thin module!! • 10GigE • SDH - STM-64 thru E1 • SONET - OC-192 thru DS1 • 10/100/1000Mbps Ethernet and Optical GigE OSA Module • CWDM/DWDM testing (1250nm to 1650nm) • Single/Dual Port options • Channel Isolation Drop User Interface Module (UIM) Transport Module – 10GigE, SONET, SDH and Ethernet OSA Module – 1250-1650nm, Channel Drop and Single/Dual Port Platform also includes - OTDR, PMD and CD modules Battery Pack

  18. Transport ModuleHighlights • Less than 7 kg fully populated (UIM + Module + Battery) • Contained in one 5 cm module • Electrical Interfaces include DS1, E1, E3, DS3, E4, STS-1 and STM-1e • SDH/SONET Interfaces include 155M/622M/2.5G/10G (1310nm, 1550nm) • 10/100/1000Mbps and Optical GigE/10GigE LAN (850nm, 1310nm and 1550nm) • Single and Dual Port for GigE • Dual Receivers for DS1, E1, E3, DS3 & STS-1 • FST-2802 - User Interface Design • Field exchangeable connectors • Enables easier connector cleaning • Minimizes the need for Hybrid jumpers • Highly configurable/Fully upgradeable Ex. STM-64 only, STM-64/10GigE

  19. MTS 8000: Built-in Connection Check • VFL • Analysis of bend/break on patch panels/ jumpers • Power Meter • Analysis of the loss of the jumpers • Absolute power measurement • Optical Fiber Microscope • Analysis of the quality of the connectors Dirty connector: Increased IL and ORL! Clean connector Get the right measurement of your network!

  20. Complete Fiber Characterization Solution • Conventional Testing • OTDR, IL, ORL, Length • Dispersion Testing • Polarization Mode dispersion • Fixed Analyzer method • 45dB dynamic range • From 0.1 to 60ps delay measurement • Chromatic Dispersion • Pulse Delay Method (Time domain) • 30 dB dynamic range • From 0.1 to 100 ps/nm.km dispersion range • Spectral Attenuation • Loss over the fiber length between in the C and L-band

  21. 50% + Time Savings ! MTS-8000: New automatic bi-directional analysis (SW option) Traditional Bi-directional Analysis : • True splice loss measurement • Reveals events that are hidden by dead zones in one direction • Possible error handling: incorrect setup • Possible error handling: incorrect fiber • Transfer all files end of the day ACTERNA Automatic Bi-directional Analysis : • True splice loss measurement • Reveals events that are hidden by dead zones in one direction • No operation error. Same setup • Automatic fiber continuity check • Immediate trace alignment with correct parameters Installer test: Bi-directional analysis at 2 s 2 hours for 72 fibers.

  22. OSA-160 INsingle port OUTCH-drop option DWDM Testing Solution • DWDM System testing • OSA-160/161/200/201 with channel isolator capability • Powerful Alarm management • Set of alarms define for each channel • Advanced Grid selection • Multiple grid settings (ITU-T, manual, Auto…) • Channel detection according to the Grid

  23. Family of Solutions Network MTS/T-BERD 8000 FC + Transport + Ethernet MTS/T-BERD 6000 Fiber Characterization (FC) including OTDR, CD, PMD… MTS-5100 OTDR/PM Scalability

  24. Automatic fault location Remote Testing and Measurement Advanced measurement analysis OSS Interface Domains Segmentation Physical & Photonic Web Access OSP & GIS documentation Reports, Quality of Service ... Extensive Alarm management Performance Trend & pro-active maintenance Optical Network Management System ONMS Page 26

  25. OFM : Optical Fiber Mapping : OFM • Network documentation including GIS New ONMS? • ONMS is an Optical Network Management System. • ONMS includes three main applications: • Remote Fiber Test System • Using MTS OTDR Modules • In service and Out of service Monitoring • DWDM Performance Monitoring • Using MTS OSA modules.

  26. Accesspoints Cables Buildings Utilities Streets Roads, Railways Administrative Boundaries What is OFM? • A complete software application for documentation, operating and maintenance of fiber optic outside/inside plant facilities • OFM is based on a Geographical Information System (GIS) tabular data Spatial data Network Layers Background maps

  27. ONMS Why? • Quickly Detect and isolate faults • Detect cable breaks, fiber tapping, • moisture intrusion, splice degradation... • Minimize Outages • DWDM performance management • Physical Security (fiber optic fence..) • SLA Management • Competitive advantage

  28. ONMS Why? • Increase workforce productivity and efficiency: • By decreasing time to turn up new services (from 30 days down to 5 days) • By reducing technician dispatches (goal: 50%, Operational cost saving) • By reducing need for specialists in the field • Improve service to end customer (Dark fiber or  provider) • By reducing network downtime/Improve quality of service (MTTR -30%) • Better SLA Management • Take control of network resources • By improving the management of fiber plant resource • By knowing the performance of available resource (fiber characterization)

  29. RTU (Remote Test Unit) ONMS LA Customers • Megacable (Mexico) • Metronet (Mexico) • CableMas (Mexico) • CableVision of Monterrey (Mexico) • Alcatel/Petrobras (Brazil) • Telemar (Brazil) - Biggest system currently deployed • Furukawa (Brazil) • ICE (Costa Rica) • Telecom Argentina (Argentina) • Telefonica Movistar (Venezuela) • Colombia Telecomunicaciones (Colombia) • CableSula/Sulanet (Honduras)