1 / 4

Beam Scraping, Diffusion and Repopulation MD

Beam Scraping, Diffusion and Repopulation MD. G. Valentino, R. W. Assmann , R. Bruce, F. Burkart , M. Cauchi , D. Deboy , L. Lari , S. Redaelli , B. Salvachua , G. Stancari , D. Wollmann. Beam Halo Study Motivation.

lora
Télécharger la présentation

Beam Scraping, Diffusion and Repopulation MD

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Beam Scraping, Diffusion and Repopulation MD G. Valentino, R. W. Assmann, R. Bruce, F. Burkart, M. Cauchi, D. Deboy, L. Lari, S. Redaelli, B. Salvachua, G. Stancari, D. Wollmann

  2. Beam Halo Study Motivation • Diffusion model developed by G. Stancari for Tevatron data. • Match loss spikes before, during and after collimator steps, both inward and outward. • Diffusion coefficient used to predict spike height. • Determination of BLM-to-intensity calibration factors with applications to lifetime and collimation system performance (F. Burkart) Courtesy: G. Stancari • Results will be extrapolated to 7 TeV to predict possible intensity limitations. • Time evolution of beam losses in collimator scan gives information on: • Halo diffusion, halo population, emittance growth, lifetime, … • Measurements will profit from the new 12.5 Hz BLM data for greater resolution.

  3. MD Requirements • 450 GeV(3 hours):- 1 – 3 fills • 4 TeV(3 hours incl. ramps):- 1 fill • Emittance: 2µm – 4µm, injection optics • Both beams, 1 nominal bunch per beam • BLMs and collimator movements masked • Collimators retracted beyond physical aperture at 15 sigmas • Reduce interference from other collimators during scraping

  4. MD Programme • Studies to be performed at 450 GeV and 4 TeV: • Retract all collimators except TCP IR7 as far as possible (ideally 15 sigmas). • Move IR7 TCP in one beam in steps of 10 µm – 50 µm every 10 seconds (or until losses decay). • Periodically measure emittance. • Put IR7 TCP back to the starting position, and wait for losses to increase (halo repopulation). • Repeat for other IR7 TCPs as long as there is time. • Dump beams with a further scraping to estimate diffusion in the core. • MD slot shift request: • MD slot currently foreseen for 24th June from 00:00 to 06:00. • Swap with slot on 19th – 21st or 25th June would be appreciated due to unavailability of some team members.

More Related