Optical Gigabit Ethernet

Optical Gigabit Ethernet. Group F.O.R.E. March 31, 2005 Ronen Adato. Progress Overview. Completed Midterm Report Soldered and Tested 2 Conservative Design Boards. Conservative Board 1. Soldered all components and tested the Rx circuit for a clear eye

lynne
Télécharger la présentation

Optical Gigabit Ethernet

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optical Gigabit Ethernet Group F.O.R.E. March 31, 2005 Ronen Adato

  2. Progress Overview • Completed Midterm Report • Soldered and Tested 2 Conservative Design Boards

  3. Conservative Board 1 • Soldered all components and tested the Rx circuit for a clear eye • Errors in part selection prevented BER testing for the Rx circuit, and any Tx circuit testing Rx Circuit Test Setup Eye Produced by Rx Circuit, Signal PRBS 7

  4. Conservative Board 1 • QMAs were sent instead of SMAs • We elected to attempt and use these incorrect parts • A clear eye was produced by the Rx circuit, but the coaxial cables had to be held tightly into the QMAs • BER testing of the Rx circuit was impossible as a consistent signal could not be achieved with the QMAs • Tx circuit was not tested as this would have been very difficult with the QMAs

  5. Conservative Board 2 • SMAs were removed from the test board to be used in the prototype • The QMAs were removed from the original board • Attempts to insert the SMAs into the holes occupied by the QMAs resulted in the destruction of a trace Board 1 With QMAs Removed The Destroyed Trace

  6. Conservative Board 2 • The VCSEL and ROSA were de-soldered and a new board was constructed • The VCSEL was recycled while a new ROSA was used • The Limiting Amplifier (MAX3264) was incorrectly placed and had to be removed and re-soldered The Second Conservative Board

  7. Conservative Board 2 • The Rx circuit failed to produce an eye • It was determined that the LA (MAX3264) had been damaged Rx Circuit Waveform Measured Before LA Rx Circuit Waveform Measured After LA

  8. Conservative Board 2 • The Tx circuit was tested and does not work • The VCSEL is not lasing • Voltage measurements were taken throughout the circuit • In general, the entire loop around the VCSEL has a 5V dc voltage • Potentiometer adjustments changed nothing • We suspect our VCSEL may not be functioning

  9. GANTT Chart

  10. Tasks for Next Week • Replace the LA in the Rx circuit and retest, including BER measurements • Fix and test the Tx circuit • The VCSEL will probably be replaced • Loop-back test the entire board • Solder and test the aggressive design