80 likes | 179 Vues
Analyzing UV epoxy thickness in Zeus-2 optic unit using Excel and QC-CALC. 3 units are out of tolerance due to insufficient UV epoxy. The BLT measure of UV epoxy is 12±5um. Conclusion: BLT data exceeds spec limits.
E N D
Zeus-2 buy0ff data Optic Engineer Team 2010/04/24
3 unit out of tolerance, because of UV epoxy insufficient. Normal UV epoxy insufficient UV epoxy insufficient UV epoxy insufficient
BLT Measure BLT of UV epoxy (Unit: um) Spec.: 12±5um Conclusion: BLT data is out of spec.s