An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Damien SimonRCDD - LAN Specialist

  2. Haupt Server Außen Kupfer BB Voice / Data Kupfer Linie Data LWL Linie Außen LWL BB Video CATV Verbindung mit anderen Systemen EVt HVt PABX Seite HVt BB Seite GVt CVt PABX Blitzschutz Klima/Heizung Doorkeys Minibar Feuermelder Rauchmelder Entrance Facilities

  3. Themen • Normen heute • Categorie 6 - De-embedded • Categorie 7 - GG45 • LWL Klassen OM1, OM2, OM3 • Neue Faser Channels

  4. Normen in 2002 INTERNATIONAL ISO/IEC 11801:2002 EUROPA / CENELEC EN 50173:2002 USA EIA/TIA 568-B.2.1 - Ratifiziert am 13. August 2002 - Publiziert Oktober - Kabel definiert in IEC61156-5 - Connector definiert im IEC 60603-7-5 (Kat.6) - IEC60603-7-7 (Kat.7) - Ratifiziert am 13. August 2002 - Publiziert Oktober - Kabel definiert in EN50288 - Connector definiert in EN-60603-7-5 (Kat.6) - EN60603-7-7 (Kat.7) - Ratifiziert Juni 2002 - Publiziert am Juli 2002 Verkabelung und Komponenten inkludiert

  5. Neue Ausgabe 2002 USA EIA/TIA 568-B.2.1 INTERNATIONAL ISO/IEC 11801:2002 EUROPA CENELECEN 50173 - Klasse D/E/F - Kat. 5/6/7 - 2-3-4 Connectors Linkmodelle - Neue Architektur - LWL Klassen OM1-OM2-OM3 LWL Channels OF300-OF500-OF2000 B-1 : Commercial Building Tele- communication Cabling Standard B-2 : Balanced Twisted Pair Cabling Components B-3 : Optical Fibre Cabling Coponents Standard - Klasse D/E/F - Kat. 5/6/7 - 2-3-4 Connectors Linkmodelle - Neue Architektur - LWL Klassen OM1-OM2-OM3 LWL Channels OF300-OF500-OF2000

  6. Klasse F / Kategorie 7 Klasse E / Kategorie 6 Kategorie 4 Klasse D / Kategorie 5 neue) Category 5 / Class D Category 4 Klasse C/Kategorie 3 Infrastruktur - Normierung neu gelöscht ratifiziert ratifiziert 600 MHz 16 MHz 20 MHz 100 MHz 250 MHz

  7. Gigabit ATM Cat.6* (CB1G) Gigabit Ethernet Cat.6* (1000Base-TX) ??? Gigabit Ethernet ** /Multimedia Gigabit Ethernet 250 MHz Category 6 10 Gigabit Ethernet * Class E Fast Ethernet 100 MHz Category 5e Class D99 D2000 Ethernet 100 MHz Category 5 Class D Jahr 2015 Jahr 2010 Jahr 1995 Jahr 2000 Jahr 2005 Jahr 2007 Normierung - Anwendungen Standards 600 MHz Category 7 Class F * - Standardisierung in Arbeit ** - Standardisierung noch nicht begonnen

  8. Themen • Normen heute • Categorie 6 - De-embedded • Categorie 7 - GG45 • LWL Klassen OM1, OM2, OM3 • Neue Faser Channels

  9. Themen • Was ist de-embedded • Erklärung • Wie wichtig ist de-embedded

  10. Was ist de-embedded • Test Verfahren um den NEXT und FEXT Bereich des Steckers allein zu bestimmen (die Pyramide ist eine vorgeschlagene Messkonfiguration um FEXT zu Messen) • um Interoperabilität zu garantieren (Kat.6 Leistungen mit allen herstellerunabhängigen Kat.6-Steckern und allen herstellerunabhängigen Kat.6 Buchsen) • für NEXT und FEXT des Steckers • keine Verschärfung der Werte • Bereich/Fenster in welchem NEXT und FEXT des Steckers sich befinden soll (um sicher zustellen, dass alle die gleichen Werte haben = Interoperabilität)

  11. Was ist de-embedded ISO/IEC11801:2002 EN50173:2002 Verkabelung ISO/IEC und EN noch nicht ratifiziert TIA ist bereits ratifiziert IEC60603-7-5 EN60603-7-5 RJ45 Steckverbinder inkl. de-embedded Test

  12. Themen • Was ist de-embedded • Erklärung • Wie wichtig ist de-embedded

  13. De-embedded Plug Jack Beide Steckverbinder ‘funktionnieren’ . Sie sind aber nicht kompatibel.

  14. De-embedded Plug Jack

  15. Kat.6 Leistungen von 4 unterschiedlichen Kat.6 Buchsen NEXT Werte um 100 MHz (Paar 1-3) für 4 unterschiedliche Buchsen Kat.6 Buchse + Stecker Kat.6 Buchse + Stecker Klasse E Buchse + Stecker Kat.6 Buchse + Stecker Kat.6 Grenze(54/52.5db at 100 Mhz) Kat.5 Grenze 34 35 36 39 37 38 Kat.6 Stecker Bereich Stecker Kat.5e Stecker Bereich

  16. Themen • Was ist de-embedded • Erklärung • Wie wichtig ist de-embedded

  17. Wie wichtig ist de-embedded • Vorteile • Normkonformität • funktioniert mit jedem (de-embedded) Patchcord • Nachteile • bringt keine besseren Übertragungseigenschaften • funktioniert nur mit de-embedded Patchcords • z.Zt. nicht messbar im Feld

  18. Wie wichtig ist de-embedded • Größter Vorteil : Messung • kein herstellerspezifischer Testadapter nötig • kein Permanentlink-Adapter nötig • Channel kann mit jedem Patchcord gemessen werden • Channel Messung ist Wertvoller • Channel Adaptor ist billiger als Permanentlink-Adapter • Wenn Patchcords defekt: günstiger Ersatz

  19. Netzwerk Ausfallzeit - geschätzte Stunden pro Monat - 5 Std Stunden 5 System Downtime When questioned about problems with existing networks, 27% said they had problems with cabling. The major causes were identified as installation and component faults, followed by component mismatch and bandwidth limitations. Estimated downtime per month was 3.17 hours. This downtime was linked to the age of the network and its type. Networks installed in the last 2 years had an average downtime of 1.92 hours per month, rising to 5.27 hours for installations over 5 years old. There was also a very marked difference between all users of Category 5 cabling with average monthly downtime of 1.64 hours and all non category 5 users with 8 hours downtime. 3.7 Std 4 3 2 Std 2 1 Im Durchschnitt Netzwerk < 2 Jahre Netzwerk > 5 Jahre Source : End User Survey 1999

  20. Netzwerk Ausfallzeit Netzwerk Ausfallzeit : Hauptgründe Installations- und Komponentenfehler Komponenten Fehlanpassung Bandbreiten Begrenzung Source : Jamesford Consulting

  21. Patch cord Horizontal Cable Patch cord Connector Connector Data Out Data In Data Out Data In

  22. Impedanz Fehle Impedanz Fitted (smoothed) Impedanz = 98.3ohms FITTED oder MEAN bleibt aber ca. 100 ohms

  23. Kosten des Endkunden- Infrastruktur-Investition • Strukturierte Verkabelung macht 5% des gesamten IT Budgets aus Activ Verkabelung PC’s Software

  24. Infrastruktur - Lebensdauer kontra Investition Verkabelung Produkt Lebensdauer Aktiv Netwerk Investition Bedingter potentieller Netzwerkausfall Arbeitsstationen Software

  25. Themen • Normen heute • Categorie 6 - De-embedded • Categorie 7 - GG45 • LWL Klassen OM1, OM2, OM3 • Neue Faser Channels

  26. Nexans setzt Standards Steckverbinder für 600 MHz Kat.7 Stecker GG45 Kat.7 Buchse GG45 100% RJ45 rückwärtskompatibel

  27. "2 in 1" Connector "2in 1„ • High Speed + RJ45 Interface • Kat.7 + Kat.6 • 600MHz + 250 MHz • Daten+ Multimedia • Bandbreite + Zuverlässigkeit • Zukunftssicherheit + Kosteneffizienz • Möglichkeiten von morgen + Anforderungen von heute

  28. Class F und Multimedia Keine „neue“ Anwendung, aber Integration • heutige Anwendungen auf einem shared Medium „Eine Lösung für alle “

  29. Application sharing • Application sharing = mehrere Anwendung gleichzeitig • Wieviel Anwendungen ? 1 pr Video (CATV) 2 prs Daten (Ethernet, Token Ring etc) 1 pr Voice (analogue Tel.; Fax) • Leistungsbedarf : • Bandbreite: bis 862 MHz für CATV • PimF

  30. Neue Anwendung • Neue Entwicklungen in IEEE in 2002 • 1 GBase TX2: Gigabit Ethernet over Class F • 1 GBase TX4 Gigabit Ethernet over Class F • Neue working groups für 10 Gigabit Ethernetauf Kupfer • working groups started November 2002 • 10GBase-CX4 – 15m • 10GBase-T (100m) • Fertig 2006 (Ziel)

  31. Klasse F Kosten Sonstige 50% Installation 31% Kabel & Anschlußkomp. Verkabelung ist 5% des IT Budgets

  32. Klasse F Kosten • 1. Kat. 7 Kabel und Anschlußkomponenten 2x teurer (2 x 31% = 62 %) • 2. Kat.7 braucht 20 % mehr Installationszeit (50 %*1,2= 60%) • Kat.7 ist ca. 41 % teurer, aber..

  33. Klasse F Kosten Verkabelung ist 5% des IT Budgets Kat.7 = +41 % von 5 % = 2,15 % Total Kost für Verkabelung = 7,15 % 2,15 % zuzästlische Kosten wegen Kat.7

  34. Cat.5 Cat.6 Cat.7

  35. 4 Connector Channel

  36. 300 MHz

  37. 350 MHz

  38. GG45

  39. Themen • Normen heute • Categorie 6 - De-embedded • Categorie 7 - GG45 • LWL Klassen OM1, OM2, OM3 • Neue Faser Channels

  40. Neue Ausgabe 2002 USA EIA/TIA 568-B.2.1 INTERNATIONAL ISO/IEC 11801:2002 EUROPA CENELECEN 50173 - Klasse D/E/F - Kat. 5/6/7 - 2-3-4 Connectors Modelle - Neue Architektur - LWL Klassen OM1-OM2-OM3 - LWL Channels OF300-OF500-OF2000 B-1 : Commercial Building Tele- communication Cabling Standard B-2 : Balanced Twisted Pair Cabling Components B-3 : Optical Fibre Cabling Coponents Standard - Klasse D/E/F - Kat. 5/6/7 - 2-3-4 Connectors Modelle - Neue Architektur - LWL Klassen OM1-OM2-OM3 LWL Channels OF300-OF500-OF2000

  41. Funktionniert 1 Gbit Ethernet SX ? Funktionniert 1 Gbit Ethernet LX? Funktionniert 10 Gbit Ethernet ?

  42. Anwendungen - Faser Typen - Strecke • Die maximale Stecken Länge ist abhängig von : • Faser Type • Anwendung

  43. Themen • Neue Faser Klassen • Launch conditions • 10Gb/s Ethernet

  44. Neue Faser Klassen ISO 11801 - EN 50173 and TIA • 4 Faser Klassen : Minimale Leistungen • Multimode OM1 • Multimode OM2 • Multimode OM3 • Singlemode OS1

  45. Faser Klassen 1500 2000 Am wichtigsten ist Bandbreite um 850nm Gleiche Dämpfung

  46. Themen • Neue Faser Klassen • Launch conditions • 10Gb/s Ethernet

  47. High number of modes = high dispersion Middle number of modes = lower dispersion Few number of modes = very low dispersion Wirkung von Launch conditions auf Bandbreite T LED overfills the fibre VCSEL underfills the fibre LASER is extremely restrictive