1 / 19

Agenda

Agenda. Heparin resistance BJA, 2002 vol 88, no 4, 467-469 J A M Anderson and E L Saenko. Overview. Heparin was discovered in 1916 Most widely used anticoagulant but not all its actions are fully understood

mort
Télécharger la présentation

Agenda

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Agenda • Heparin resistance • BJA, 2002 vol 88, no 4, 467-469 • J A M Anderson and E L Saenko

  2. Overview • Heparin was discovered in 1916 • Most widely used anticoagulant but not all its actions are fully understood • Eg: pain relief in i.v administration for the treatment of DVT, how HIT developed and what is the relevance of the occurrence of heparin resistance

  3. Indications • Prevention of VTE • Treatment of VTE • Acute coronary syndrome • Surgery: cardiac bypass

  4. Introduction • Heparin is a negatively charged sulphated glycosaminoglycan composed of alternating uronic and glucoronic acid residues • Commercially prepared are isolated fr porcine int mucosa or bovine lungs. There are heterogenous mixtures of polysacharide chains ranging in molecular weight from 3000 to 30,000. • Mode of action:

  5. MOA 1 • 1. Antithrombin dependent • -Activate AT Hep-AT complex • inactivate thrombin, fXa and other coagulation factors • The combination of disaccharide units makes-up pentasacharide sequence containing high affinity binding site for AT. This sequence occurs in only about 1/3 rd of heparin chains and is randomly distributed

  6. MOA 2 • 2. AT independent • Direct Inhibition of the intrinsic tenase complex ( PL complex of FVIIIa, FIXa which generates Fxa) • * In plasma milieu, AT-dependent effect predominates • In vivo, variation in response to a fixed dose of heparin occurs bet individuals • Pharmacokinetics limitation of heparin caused by the binding of hep to plasma proteins  Heparin resistance state

  7. Significance to know the ‘R’ state • 1. Prevent over administration of heparin hemorrhagic consequences • Particularly during post-op or in the setting of cardiac bypass surgery and to consider alternative therapy • 2. In VTE  the phenomenon is of unclear clinical practice

  8. Definition of heparin resistance state • 1. In the context of VTE: • The need for more than 35,000 u/24 hour to prolong the APTT into the therapeutic range • 2. Cardiac bypass procedure: • The definition is based on the ACT with at least one ACT < 400 secs after heparinization and/or the need for exogenous antithrombin administration

  9. Questions • 1. What causes heparin resistance • 2. Which patient groups are susceptible? • Some answers can be gained from the understanding on the limitation of UFH

  10. Limitations of heparin • 1. Biophysical • Reflects the inability of hep-AT complex to inactivate FXa bound to platelets within the prothrombinase, the PL memb bound fVa – fXa complex, • in addition to the resistance of fibrin bound thrombin to inactivation by heparin

  11. Limitation of heparin 2 • 2. Pharmacokinetic • A. Reflects the binding of hep to plasma proteins including PF4, fib, fVIII and histidine rich glycoprotein • As many heparin- binding poteins are acute phaase proteins/reactants- the phenomenon is often encountered in acutely ill pts, malignancy, peri or post partum periods and drugs ( aprotinin and nitroglycerin – hep clearance) • B. Lowering of the AT levels by heparin  contributes to the resistance state

  12. How to monitor the anticoagulant effects of heparin in the lab? … not easy • 1. APTT failed to prolonged • APTT has its own limitations: • Influenced by: • -blood collection • -Sampling tube composition • -Type of anticoagulant • -Time of sampling to avoid PF4 mediated neutralization of heparin • * APTT response to heparin varies

  13. APTT response to Heparin • Possibolity of ApTT lies in the target range for heparin therapy whilst the heparin levels is suboptimal occurs in acquired/congenital factor deficiency, LA, warfarin effects.

  14. Monitor • 2. Anti- Xa monitorring • Less dose of heparin is required compared to when APTT is used as monitorring agent • The development of heparin resistance is therefore an indication for the use of the heparin assay to measure the anticoagulant effect of the drug • Chromogenic anti fXa assays have limitations: assay variation and technique • Bedside anti fXa monitorring test to permit a quicker and more accurate asessment of the true anticoagulant activity of heparin: bypass surgery

  15. Monitor • 3. ACT • At present ACT, is the most commonly used lab test to control heparin effects on extracorporeal membrane • ACT results also dependent on the instrumentation, vary with the presence of haemodilution and hypothermia

  16. Heparin Resistance and CPB • CPB circuitECM: activate the coagulation pathway  fXa generation. The inhibition of Fxa in these situations involves the AT dependent mechanisms of heparin. • Imbalance of activation of FX via extrinsic vs intrinsic p/way • In general, hep is given 3mg/kg body wt to prevent extracorporeal clot formation with repeated doses to maintain ACT > 400 sec to maintain level at 3iu/ml

  17. Solution to heparin resistance during CPB • Potential solution: Argatroban: a selective, reversible thrombin inhibitor • Hirudin also a direct thrombin inhibitor : prevent clotting within the CPB circuit of pts with HIT • Ecarin clotting time to monitor the antithrombotic effects (PT activation by the snake venom) • Pentasacharide: a selective synthetic fXa inhibitors: once daily subcut dose without monitoring requirement (prevention of venous thrombosis)

  18. Conclusion • Heparin still remains the optimal means of anticoagulation in CPB, but improvements are needed in terms of practical bedside monitorring of its anticoagulant effects. • Bedside monitorring permit reasessment of the optimal level of ACT to achieve prior to starting the bypass circuit

  19. Significance of heparin resistance • In the context of VTE- heparin R has its clinical relevance? • What is the outcome of pts treated with empirical doses of heparin when APTT cannot be prolonged into the therapeutic range? • The optimal means of monitorring the anticoagulant effects in cardiac surgery? to avoid bleeding post-op and usage of blood products • Oral heparin in future and synthetic indirect and direct fXa inhibitors.

More Related