An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CHROMATOGRAPHY A guide for A level students 2008 SPECIFICATIONS KNOCKHARDY PUBLISHING

  2. CHROMATOGRAPHY INTRODUCTION This Powerpoint show is one of several produced to help students understand selected topics at AS and A2 level Chemistry. It is based on the requirements of the AQA and OCR specifications but is suitable for other examination boards. Individual students may use the material at home for revision purposes or it may be used for classroom teaching if an interactive white board is available. Accompanying notes on this, and the full range of AS and A2 topics, are available from the KNOCKHARDY SCIENCE WEBSITE at... www.knockhardy.org.uk/sci.htm Navigation is achieved by... either clicking on the grey arrows at the foot of each page or using the left and right arrow keys on the keyboard

  3. CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are several forms of chromatography

  4. CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are several forms of chromatography TYPE STATIONARY PHASE MOBILE PHASE paper solid (filter paper) liquid thin layer (tlc) solid (silica) liquid column solid (silica) liquid high pressure liquid (hplc) solid (silica) liquid gas liquid (glc) solid or liquid gas

  5. PAPER CHROMATOGRAPHY Stationary phase chromatography paper Mobile phase suitable solvent (water, ethanol, organic solvent) Separation As the solvent moves up the paper it dissolves the components and moves them up the paper. The more soluble a component is, the further it moves. Place small a spot of the mixture to be analysed (and any possible component for comparison purposes) on the paper. Dip the paper in the solvent.

  6. PAPER CHROMATOGRAPHY Stationary phase chromatography paper Mobile phase suitable solvent (water, ethanol, organic solvent) Separation As the solvent moves up the paper it dissolves the components and moves them up the paper. The more soluble a component is, the further it moves. Place small a spot of the mixture to be analysed (and any possible component for comparison purposes) on the paper. Dip the paper in the solvent. Allow the solvent to rise up the paper. Each component dissolves in the solvent. Those which are more soluble travel further up the paper.

  7. PAPER CHROMATOGRAPHY Stationary phase chromatography paper Mobile phase suitable solvent (water, ethanol, organic solvent) Separation As the solvent moves up the paper it dissolves the components and moves them up the paper. The more soluble a component is, the further it moves. Place small a spot of the mixture to be analysed (and any possible component for comparison purposes) on the paper. Dip the paper in the solvent. Allow the solvent to rise up the paper. Each component dissolves in the solvent. Those which are more soluble travel further up the paper. Finished chromatogram

  8. PAPER CHROMATOGRAPHY Rf value Under similar conditions, a component should always travel at the same speed. Its identity can be found by comparing the distance it moves relative to the solvent. Rf = distance travelled by the component = Y distance travelled by the solvent X X Y

  9. PAPER CHROMATOGRAPHY Rf value Under similar conditions, a component should always travel at the same speed. Its identity can be found by comparing the distance it moves relative to the solvent. Rf = distance travelled by the component = Y distance travelled by the solvent X Comparison can be a problem if… a) components have similar Rf values b) the unknown substance is new and there is no previous chemical to compare it with X Y

  10. THIN LAYER CHROMATOGRAPHY Stationary phase silica mounted on a glass plate Mobile phase suitable organic solvent Separation similar technique to paper chromatography Limitations similar to paper chromatography

  11. COLUMN CHROMATOGRAPHY Stationary phase silica Mobile phase suitable organic solvent Separation components interact with the stationary phase to different extents A B B C

  12. COLUMN CHROMATOGRAPHY Stationary phase silica Mobile phase suitable organic solvent Separation components interact with the stationary phase to different extents Method • a chromatography column is filled with solvent and silica • drops of the mixture are placed on top of the silica - A • the tap is opened to allow the solvent to flow out • additional solvent is added on top to replace that leaving • components travel through at different rates and separate - B • batches of solvent are collected at intervals - C • the solvent in each batch is evaporated to obtain components A B B C

  13. HIGH PRESSURE LIQUID CHROMATOGRAPHY (HPLC) A better form of column chromatography. Instead of draining down through the stationary phase, the solvent is forced through under high pressure. Stationary phase silica Mobile phase suitable solvent Separation similar to column chromatography

  14. HIGH PRESSURE LIQUID CHROMATOGRAPHY (HPLC) A better form of column chromatography. Instead of draining down through the stationary phase, the solvent is forced through under high pressure. Stationary phase silica Mobile phase suitable solvent Separation similar to column chromatography Method • a sample is injected • solvent and sample are pushed through under pressure • different compounds have different retention times • output can be detected by compounds absorbing UV • can be connected to a mass spectrometer

  15. HIGH PRESSURE LIQUID CHROMATOGRAPHY (HPLC) A better form of column chromatography. Instead of draining down through the stationary phase, the solvent is forced through under high pressure. Stationary phase silica Mobile phase suitable solvent Separation similar to column chromatography Method • a sample is injected • solvent and sample are pushed through under pressure • different compounds have different retention times • output can be detected by compounds absorbing UV • can be connected to a mass spectrometer Advantages • it is fast • the path is short - usually under 30cm • it gives better separation

  16. GAS LIQUID CHROMATOGRAPHY (GLC) Stationary phase liquid adsorbed on an inert solid support Mobile phase gas Method • a very small amount of a sample is injected into the machine • the injector is contained in an oven • the sample boils and is carried along a thin column by an inert carrier gas • column contains a liquid stationary phase, adsorbed onto an inert solid • the time taken to travel through the tube will depend on how much time is spent moving with the gas rather than being attached to the liquid.

  17. GAS LIQUID CHROMATOGRAPHY (GLC) Retention time The time taken for a compound to travel through the column to the detector. It is measured from the time the sample is injected to the time its peak shows maximum height.

  18. GAS LIQUID CHROMATOGRAPHY (GLC) Retention timeThe time taken for a compound to travel through the column to the detector. It is measured from the time the sample is injected to the time its peak shows maximum height. For a particular compound, the retention time depends on... boiling point high boiling point = long retention time

  19. GAS LIQUID CHROMATOGRAPHY (GLC) Retention timeThe time taken for a compound to travel through the column to the detector. It is measured from the time the sample is injected to the time its peak shows maximum height. For a particular compound, the retention time depends on... boiling point high boiling point = long retention time solubility in the liquid phase greater solubility = long retention time

  20. GAS LIQUID CHROMATOGRAPHY (GLC) Retention timeThe time taken for a compound to travel through the column to the detector. It is measured from the time the sample is injected to the time its peak shows maximum height. For a particular compound, the retention time depends on... boiling point high boiling point = long retention time solubility in the liquid phase greater solubility = long retention time ANIMATION

  21. GAS LIQUID CHROMATOGRAPHY (GLC) Detection • there are several ways to detect components • most involve destruction of the sample • one method is an FID - flame ionisation detector The FID • as a component exits, it is burned in a hydrogen flame • ions are produced in the flame • a detector produces an electric current • greater the amount of a component = larger current • the current can be represented by a chromatogram • as the component is destroyed, GCMS doesn’t use FID

  22. GAS LIQUID CHROMATOGRAPHY (GLC) Interpretation • each compound in the mixture will produce a peak • the areas under the peaks are proportional to the amount of a compound • retention times are used to identify compounds – they are found out by putting known compounds through the system under similar conditions The area under a peak is proportional to the amount present. Because each compound responds differently, the machine is calibrated beforehand to show the actual mount. Each component has a different retention time.

  23. GAS CHROMATOGRAPHY – MASS SPECTROMETRY (GCMS) Process When a peak is detected in gas chromatography, some of the component is sent to a mass spectrometer A mass spectrometer has three main parts...

  24. GAS CHROMATOGRAPHY – MASS SPECTROMETRY (GCMS) ProcessWhen a peak is detected in gas chromatography, some of the component is sent to a mass spectrometer A mass spectrometer has three main parts... Ioniser - the sample is bombarded with electrons and ionised - a positive molecular ion is formed - the molecular ion can break up into smaller ions - positive ions are accelerated towards the analyser

  25. GAS CHROMATOGRAPHY – MASS SPECTROMETRY (GCMS) ProcessWhen a peak is detected in gas chromatography, some of the component is sent to a mass spectrometer A mass spectrometer has three main parts... Ioniser - the sample is bombarded with electrons and ionised - a positive molecular ion is formed - the molecular ion can break up into smaller ions - positive ions are accelerated towards the analyser Analyser - positive ions separate according to mass/charge ratio - higher mass/charge ratio = smaller deflection

  26. GAS CHROMATOGRAPHY – MASS SPECTROMETRY (GCMS) Process When a peak is detected in gas chromatography, some of the component is sent to a mass spectrometer A mass spectrometer has three main parts... Ioniser - the sample is bombarded with electrons and ionised - a positive molecular ion is formed - the molecular ion can break up into smaller ions - positive ions are accelerated towards the analyser Analyser - positive ions separate according to mass/charge ratio - higher mass/charge ratio = smaller deflection Detector - records the identity and abundance of each ion - compounds have a unique mass spectrum - the final peak (molecular ion) gives the molecular mass

  27. GAS CHROMATOGRAPHY – MASS SPECTROMETRY (GCMS) Process When a peak is detected in gas chromatography, some of the component is sent to a mass spectrometer A mass spectrometer has three main parts... Ioniser - the sample is bombarded with electrons and ionised - a positive molecular ion is formed - the molecular ion can break up into smaller ions - positive ions are accelerated towards the analyser Analyser - positive ions separate according to mass/charge ratio - higher mass/charge ratio = smaller deflection Detector - records the identity and abundance of each ion - compounds have a unique mass spectrum - the final peak (molecular ion) gives the molecular mass

  28. A MASS SPECTROMETER ANALYSER DETECTOR ION SOURCE • IONISATION • gaseous atoms are bombarded by electrons from an electron gun and are IONISED • sufficient energy is given to form ions of 1+ charge • ACCELERATION • ions are charged so can be ACCELERATED by an electric field • DEFLECTION • charged particles will be DEFLECTED by a magnetic or electric field • DETECTION • by electric or photographic methods For more information, consult the notes on ‘Mass Spectrometry’

  29. CHROMATOGRAPHY A guide for A level students © 2009 JONATHAN HOPTON & KNOCKHARDY PUBLISHING