1 / 19

Control Circuit Protection Miniature Circuit Breakers and Cylindrical Fuse Holders

Control Circuit Protection Miniature Circuit Breakers and Cylindrical Fuse Holders. NEW. Control Circuit Protection. 3NC1038. 3NW7. 5SJ41.-.HG4 0. Miniature Circuit Breakers. 5SJ4…-.HG4 1. NEW. Control Circuit Protection.

nedaa
Télécharger la présentation

Control Circuit Protection Miniature Circuit Breakers and Cylindrical Fuse Holders

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Control Circuit Protection Miniature Circuit Breakers and Cylindrical Fuse Holders Control Circuit Protection

  2. NEW Control Circuit Protection 3NC1038 3NW7 5SJ41.-.HG40 Miniature Circuit Breakers 5SJ4…-.HG41 Control Circuit Protection

  3. NEW Control Circuit Protection Control Circuit Protection

  4. 5SJ4 Miniature Circuit Breakers - General Features • Approvals • UL 489, Branch Circuit Protection (File E243414) • CSA 22.2 No. 5-02, Branch Circuit Protection (File E243414) • CE Mark, General & Residential Use • IEC 60 898, General & Residential Use • HACR, Heating & Air Conditioning Use • Can Be Used in North America, Europe and wherever NEMA or IEC Specifications are required. • Suitable for Branch Circuit Protection Applications (UL 489) up to 240 VAC, and 60 VDC (1-pole) and 125 VDC (2- & 3-pole) • Thermal Magnetic Protection • Can be used for “Field Wiring” applications, AWG 14 to AWG 4, Copper (Cu) Only • Visible Indicator for ON and OFF/Trip • Finger Safe Design • DIN Rail Mounting (Standard 35 mm) • Identical Wire Screw Connections on Line and Load Sides Control Circuit Protection

  5. 5SJ4...-.HG41 5SJ41..-.HG40 5SJ4…-.HG41 5SJ4...-.HG4. Mini Circuit Breakers (MCB) • 1-Pole 1-, 2- & 3-Pole • B, C & D C & D • Rated Voltage (UL 489) • 240 VAC Max. • 60 VDC Max. (1-Pole) • 125 VDC Max. (2- & 3-Pole) • Rated Current: 0.03 to 63 A (depending on device selected) • Interruption Ratings (depending on device selected) • Type HSJ: 14 kA @ 240 VAC • Type NSJ: 10 kA @ 240 VAC • Types HSJ & NSJ: 10 kA @ 60/125 VDC Control Circuit Protection

  6. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) What other differences exists between the -.HG40 and the -.HG41? Addition of Barriers in the terminal areas. Addition of Covers over the screw terminals Allows for Same Phase / Same Polarity and Reverse Feed Applications. This is a limitation of the -.HG40 MCBs 5SJ41..-HG4 5SJ4…-.HG4 1 0 Control Circuit Protection

  7. 5SJ4...-.HG41 Mini Circuit Breakers (MCB) Competitive UL 489 MCBs, 40°C WARNING! Competitive data found in this presentation is based on the catalog series identified 0n this slide. Control Circuit Protection

  8. 5SJ4...-.HG41 Mini Circuit Breakers (MCB) Control Circuit Protection

  9. 5SJ4...-.HG41 Mini Circuit Breakers (MCB) Control Circuit Protection

  10. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) Dimensions (mm) Control Circuit Protection

  11. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) • The following resources are found in: • Portal on a disk • SiteScape • Controls – D, DX, T, V Modules • IEC Control Control Circuit Protection

  12. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) 5SJ4…-. HG41Supplemental Catalog Pages Technical Data Selection 5SJ41..-.HG40 is found on pages 16/4 & 5 of the 2006 Industrial Controls Catalog. Control Circuit Protection

  13. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) 5SJ4…-. HG4. On-Line Flyer includes: - Description - Features - Application - Interrupting Ratings - Selection Guide - Dimensions Control Circuit Protection

  14. 5SJ4...-.HG41 Mini Circuit Breakers (MCB) • Pricing Strategy • 5SJ41..-.HG40 – Same List Price as Equivalent 5SY4, Single Pole, Supplementary Protectors. • 5SJ4…-.HG41 – List Price + 10% for an Equivalent 5SY4 Supplementary Protector. • Pricing Class (MG3): NAH (old C638) • Discount Code Schedule: ACMCB • Discount Code: Mini Circuit Breakers Control Circuit Protection

  15. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) Price List Includes – • Catalog Number • Page Number • List Price • Pricing Class • Discount Code • Stock Code • Description Control Circuit Protection

  16. 5SJ4...-.HG41 Mini Circuit Breakers (MCB) Product Profile Includes – • Detailed Product Description • Current Ratings at Ambient Temperatures Other than 40°C • C & D Tripping Characteristics • Catalog Number Nomenclature • Product Selection • Device Markings • Specifications • Dimensions Control Circuit Protection

  17. 5SJ4...-.HG4. Mini Circuit Breakers (MCB) Competitive Cross Reference - 25°C & 40°C Control Circuit Protection

  18. NEW Fuse Holders, Closed Type, Cylindrical • Suitable for use with Class CC Fuses • 13/32 x 1-1/2 inch (10.3 x 38.1 mm) • 0.6 to 30 A, 600V • Slow, Quick or Slow Current Limited • Fuse Holders are available without Blown Fuse Indicator • UL & CSA Listed (UL 512 and CSA C22.2, No. 39) for Branch Circuit Protection • Multiple Poles – 1, 2, & 3 • UL Rated Voltage – 600 V Class CC Fuse Holders for Branch Circuit Protection Control Circuit Protection

  19. NEW Supplementary Fuse HolderType M, Supplementary Fuses • For use with Type M, Supplementary Fuses, 13/32” x 1-1/2” (10 x 38 mm) I.E. Midget Fuses • UL Recognized to UL 512, Fuse Holders • 600 V, 30 A Rating • #14 to #6 AWG • 1-, 2-, or 3-Pole Versions • Surface Mounted • 10,000 A RMS Symmetrical Withstand Rating • Typical Fuses: Bussmann KTK, FNQ, FNM, BAF, BAN and AGU; Siemens SITOR Series Control Circuit Protection