General Operating Permit (GOP) for Combined Heat & Power (CHP) Engines & Turbines

General Operating Permit (GOP) for Combined Heat & Power (CHP) Engines & Turbines. Typical CHP Process. Engines & Turbines. Heat Input =< 65 MMBTU/hr One GOP per Title V facility Stack Height Engines: >= 35 ft if Heat Input =<20 MMBTU/hr >= 50 ft if Heat Input >20 & <65 MMBTU/hr

nishan
Télécharger la présentation

General Operating Permit (GOP) for Combined Heat & Power (CHP) Engines & Turbines

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. General Operating Permit (GOP) for Combined Heat & Power (CHP)Engines & Turbines

  2. Typical CHP Process

  3. Engines & Turbines • Heat Input =< 65 MMBTU/hr • One GOP per Title V facility • Stack Height • Engines: • >= 35 ft if Heat Input =<20 MMBTU/hr • >= 50 ft if Heat Input >20 & <65 MMBTU/hr • Turbines: >= 35 ft

  4. Engines & Turbines • May include one or more units • May include Duct Burner • System Efficiency >= 65% • Formula in NSPS 4K • Comment Periods • 30 days for public • 45 days for EPA

  5. Engines & Turbines • Restrictions • Subject to PSD • Subject to NJAC 7:27-18 • Major HAP facility • Incorporation in Title V Permit • At next permit modification • At permit renewal

  6. Engines • Fuel • Natural Gas • Propane • Performance Standards • SOTA stds for NOx, CO & VOC • AP-42 factors for TSP, PM-10 & SO2 • NSPS 4J for testing & monitoring reqs

  7. Turbines • Fuel • Natural Gas or Propane • ULS #2 fuel oil, diesel or kerosene, as backup • Backup fuel limited to 100 hrs/yr • Performance Standards • SOTA stds for NOx, CO & VOC • AP-42 factors & 15 ppm Sulfur for SO2 • Manufacturer’s guarantees for TSP & PM-10 • NSPS 4K for testing & monitoring reqs

  8. Registration Forms • Registration Forms • Fillable Format • Permit for Exact Capacity • Submittal • Email/CD • Using DEP Portal – Long Term • Read General Provisions