Next Generation CAT System

Next Generation CAT System. Non-scanning CT (computerized tomography). CT(computerized tomography) creates 3D views of what is inside. General medical imaging technique to look inside of a patient’ body. Standard CT system. Background. Motivation.

noel
Télécharger la présentation

Next Generation CAT System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Next Generation CAT System

  2. Non-scanning CT (computerized tomography) CT(computerized tomography) creates 3D views of what is inside General medical imaging technique to look inside of a patient’ body Standard CT system

  3. Background Motivation • CT machines take much time(15~20min) and real-time operation is a challenging issue. • A huge system has been required for scanning mechanism since the first invention. The first inventor of CT, Hounsfield(Nobel Prize winner, 1979) Hounsfield’s sketch

  4. CT Development History 5th ? No scanCompactSafe 1st : Linear & rotational CT 4th: spiral CT or helical CT 2nd : Multiple scanning CT 3rd : Fan-beam CT

  5. Concept for Non-scanning CT Concept of future wearable CT machines A sketch of a next generation CT for next Nobel Prize

  6. Comparison between current and conceptual CTs State-of-the-art CT(Aquilion ONE )Toshiba Medical System, 2006 Conceptual diagram of ascan-free CT For real-time 3D reconstruction

  7. Related Technique Shield Field Imaging (Douglas Lanman, RameshRaskar et al. [2008] ) • Shadow-based 3D reconstruction by a single shot image • Limitation : impossibility to local concave and backside shapes A single shot image Shield Field system 3D Reconstruction Decoupling to multi-view images

  8. Related Technique Tomographic Reconstruction of Transparent Objects ( BorislavTrifonov et al. [2006] ) • 3D reconstruction of a transparent object by tomography • using 72~360 captured images Limitation : Requirement of moving system and many captured images Capturing System One of 360 images Reconstruction Result A glass object

  9. Experimental System 6~16 LEDs and a translucent object are used here. Canon EOS 450D(12M pixels) Schematic diagram of system 150x100 pinhole array (pinhole diameter of 428 microns) Actual system

  10. Non-scanning CT based on light field capturing 3D Reconstruction of transparent objects using visible light with a single shot photo • Limitation : 3D reconstruction in low resolution because decoupled multi-view images are in low resolution, 80x80 A single shot photo Single shot CT for a translucent object 3D shape Reconstruction Decoupling to multi-view images

  11. Decoupling Process Decoupled multi-view images A Single shot LF image Decoding process of a coded 4D light field image

  12. Background Elimination Elimination of background  Reference Images

  13. 3D Reconstruction by ART Volume Reconstruction by ART(Algebraic Reconstruction Technique) 5 multi-view Images

  14. Experimental Results Multi-view images(resolution is 100x200) 3D reconstruction results