An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Warm Electronics Qualification Status PACS IQR Martin von Berg Warm Electronics Qualification Status

  2. Warm Electronics Overview Warm Electronics Qualification Status

  3. Built Standard of WE Items I Warm Electronics Qualification Status

  4. Built Standard of WE Items II PACS AVM WE integrated on SVM Panel Simulator at Astrium (QM1 BOLC ext. PSU not shown) Status: 21.12.2004 Warm Electronics Qualification Status

  5. Thermal Qualification Status • AVM / STM WE Unit testing - STM BOLC: TV test for design validation : OK - BOLC PSU sub-unit thermally tested : OK - As agreed, no tests were done with other units • CQM / AVM ILT - No testswere foreseen and done • QM / PFM WE Units - Simulations and Analysis done for all units - Full qualification programs are currently ongoing - First results for QM SPU available Warm Electronics Qualification Status

  6. Electrical Interface Qualification Status : AVM • AVM WE Unit testing by sub-contractor - No qualification tests foreseen on sub-contractor level for delivered units - no VCD available as no test foreseen • AVM WE Unit testing by MPE - Inrush current measurements for DPU, SPU : compliant - Spectrometer Groundings tested during ILT - ICC data analysis still missing for final decisions Warm Electronics Qualification Status

  7. Electrical Interface Qualification Status : QM / PFM • QM WE Units testing - Full applicable testing on sub-unit level contractually agreed - First results for QM SPU available : NCRs for Bonding R and PROM contents - Nothing available yet for other units - Qualification Test Programs are ongoing - NA for WIH • PFM WE Units testing - Full applicable testing on sub-unit level contractually agreed - All testing necessary and required prior to delivery to MPE - PFM WE Units should not be accepted without completed Test Reports Warm Electronics Qualification Status

  8. Electrical Interface Qualification Status : Power • Power Budget Is DECMEC Power Consumption final? Possible changes due to Heater / Flasher Implementation. Slight Increase of SPU Power. CR released 12.01.2005 Warm Electronics Qualification Status

  9. EMC / ESD Qualification Status : AVM • AVM WE Unit testing - No tests conducted on sub-contractor level for delivered units of DPU, SPU, DECMEC and BOLC, NA for WIH • CQM / AVM ILT - Full applicable test program done, given in EMC test specification PACS- ME-PL-015, Issue 1.2 - As run Test procedure PACS-ME-PL-015, Issue 1.2 available via CR-0020v2 - EMC Draft Test Report available, ICC Data analysis still missing - Some NCRs, RfW raised or re-issued - ESD testing not done (high risk) - Test and Compliance Matrix : see next transparency (extract of available Draft Test Report, PACS-ME-TR-038, chapter 3) Warm Electronics Qualification Status

  10. EMC / ESD Qualification Status : AVM Matrix Warm Electronics Qualification Status

  11. EMC / ESD Qualification Status : EQM /QM • EQM IST Testing - Only RS tests foreseen, acc. HP-2-ASED-PL-0037 - ESD testing omission still under discussion and not agreed • QM WE Units testing - ALL QM models are NOT deliverable items - Full applicable testing on sub-unit level contractually agreed and expected - First results for QM SPU available, NCRs for RE-E - Nothing available yet for other units - NA for WIH Warm Electronics Qualification Status

  12. EMC / ESD Qualification Status : PFM • PFM WE Units testing - Full applicable testing on sub-unit level contractually agreed and expected • PFM ILT EMC testing - full applicable testing acc. IID-A, as reflected in PACS-ME-PL-015 with exceptions for ESD and RE/RS-E/H-Field testing • PFM IST EMC testing - Only CE tests foreseen, acc. HP-2-ASED-PL-0037 Warm Electronics Qualification Status

  13. Electrical Design Status : Plans for FM • DPU AVM to DPU CFM / PFM • Changed PL I/F Board, new design • BOLC QM1 to BOLC QM2 / PFM - Changed Bandwidth (and other) of Read-out electronics - Several Changes in digital electronics - New PCB designs • DECMEC AVM to DECMEC QM / PFM - Several changes during and after ILT necessary to provide functionality and performance • SPU AVM to SPU QM / PFM - no changes (as far as reported) Warm Electronics Qualification Status

  14. Critical Qualification Items I • WIMA MKS-2 capacitors (not part of WE, are in FPU) : not yet qualified for cryogenic use • Distribution Board „Evaluation“(not part of WE, FPU) : visit at Board manufacturer „Waltron“ still pending • Cryo Harness Verification and Compliance Matrix missing • Agreement on full PFM WE Unit Qualification prior to delivery to MPE • Risk that DECMEC functionality and performance could shorten the Qualification programme. Additionally the Heater / FlasherElectronics for Photoconductor curing has to be implemented in DECMEC. • Solution for DPU 1553 Burst Mode Problem pending Warm Electronics Qualification Status

  15. Critical Qualification Items II • Spectrometer Grounding Decision after Data Analysis : Warm-end or Cold-end-Grounding • Agreement on ESD Testing at the end of EQM IST open • RS-H of Photometer / Bolometer very high • BOLC QM1 with external PS not EMC ILT tested • BOLC uncontrolled switch-off could damage the bolometers (NCR existing) Warm Electronics Qualification Status