1 / 12

12 GHz High Power RF components requirements for CEA activities

12 GHz High Power RF components requirements for CEA activities. F. Peauger – 5 Nov. 2008. 12 GHz klystron Test Stand TBL CLIC Module. see Karl’s talk. see Steffen’s talk. No needs except RF flanges and rect. waveguides. 12 GHz Test Stand.

paguiar
Télécharger la présentation

12 GHz High Power RF components requirements for CEA activities

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 12 GHz High Power RF components requirements for CEA activities F. Peauger – 5 Nov. 2008 • 12 GHz klystron Test Stand • TBL • CLIC Module see Karl’s talk see Steffen’s talk No needs except RF flanges and rect. waveguides

  2. 12 GHz Test Stand • We split the 12 GHz Test Stand activity in two steps: • Step 1: XL5 Klystron testing at SLAC and CERN • - RF components must be sent at SLAC in October 2009 • Step 2: Accelerating structure testing without and with pulse compressor • - RF components must be ready at CERN in March 2010

  3. Step 1 • The objective is to test the new XL5 klystron at full specification: • Output power: • 50 MW peak • 3.75kW average • Pulse length / rep rate: 1.5 µs / 50 Hz • Bandwidth: 50 MHz @ -3 dB • Efficiency: 40% • Gain: 50 dB • klystron pulse failure (arcs): ≤ 1 in 14 hours • RF power in harmonics: < -30dB • Matching load: < 1.15 VSWR • Stability of RF output signal: • +/- 0.5 RF deg • +/- 0.25 % amplitude Provided by CERN for October 2009 at SLAC • General specifications for high power 12 GHz components for Step 1: • Frequency: 11.9942 GHz +/- 50 MHz @-3 dB • Pulse length and rep rate: 1.5 µs, 50 Hz • VSWR: < 1.15 • Waveguide: WR90, OFE copper • Vacuum: 1x10-10 l/s leak rate for Helium • Flange: SLAC type vacuum RF flange, stainless 316 LN • Possible Baking out: up to 300 °C

  4. Particular specifications of RF components for Step 1 • Hybrid splitter specifications: • Max. Power: 50 MW peak, 4 kW average to handle • Coupling: - 3 dB, 90 degrees • Flanges: Male (x4) • RF Load specifications: • Max power: 25 MW peak, 2 kW average to dissipate • Cooling: Connections, pressure and flow rate to be specified, water temp between 20 – 30 °C • Flanges: Male • Directional coupler specifications: • Max. Power: 50 MW to handle • Coupling: - 50 dB +/- 1dB • Directivity: - 30 dB • Flanges: one male, one female vacuum flange, WR90 instrument flange at low power side • Rectangular Pumping port specifications: • Max. Power: 50 MW to handle • Isolation of pumping port from RF: < - 50 dB • Conductance: To be specified • Connection to pumping system: UHV CF Flanges, diameter to be specified

  5. Step 2 For March 2010 at CERN

  6. Specifications of RF components for Step 2 • General specifications for Step 2: → Same as general specs for Step 1 except for peak power: • Max. Power and pulse length: from 50 MW/1.5 µs to 150 MW/300 ns • Mode converter specifications: • Input/output modes: TE10□ rectangular WR90 / TE01○ circular Φ50 mm • Flanges: one male (rectangular, SLAC type), circular to be specified • Vacuum RF Valve specifications: • Input/output modes: TE01○ circular Φ50 mm • Transmission losses: 1% max • Flanges: circular flange to be specified • Circular Pumping port specifications Ф50 and Ф90 mm: • Isolation of pumping port from RF: < - 50 dB • Conductance: To be specified • Connection to pumping system: UHV CF Flanges, diameter to be specified

  7. Evaluation of the needed quantity for step 1&2 SLED2

  8. Development and procurement plan

  9. Additional aspects • Rectangular flanges: WR90, vacuum tight • SLAC type or new CERN type ? • Thermal stabilization of the components ? • Baking out of the components ?

  10. Scope of the delivery for TBL • Purchase and delivery of 12 GHz RF components for 8 PETS in TBL (2008 – 2009) • 16 RF loads: 80 MW – 140 ns – 5 Hz • 8 Directional couplers • 16 WR90 waveguide bends (90°) (H or E bends, to be confirmed) • General specifications: • Frequency: 11.994 GHz +/- 100 MHz • Max. Power: 80 MW, 140 ns, 5 Hz • VSWR: 1.15:1 max • Waveguide: WR90, OFE copper • Vacuum: 1x10-10 l/s leak rate for Helium • Flange: SLAC type vacuum RF flange, stainless 316 LN • High power loads specifications: • Flanges: Male vacuum flange • Water cooling: Connections to be specified, water temp: 20-30 °C • Length: Lengths to be approved by CERN • Directional coupler specifications: • Coupling: - 50 dB +/- 1dB • Directivity: - 30 dB • Flanges: one male, one female vacuum flange, WR90 instrument flange at low power side • Length: 30 – 50 cm (layout to be approved by CERN)

  11. Scope of the delivery for CLIC Module • Purchase and delivery of three accelerating structures with wakefield monitors (2008 – 2010) • 3 structures, 4 RF ports per structures = 12 RF ports (RF port = rect. wg + flange) • General specifications: • Frequency: 11.9942 GHz • Max. Power: 80 MW, 140 ns, 5 Hz • Waveguide: WR90, OFE copper • Vacuum: 1x10-10 l/s leak rate for Helium • Flange: SLAC type vacuum RF flange, Female, stainless 316 LN

  12. Summary • TEST STAND: • RF and mechanical design (or modification) of 12 GHz TE01 Mode Converters (Ф50), and fabrication of 7 units • based on 11.4 GHz SLAC design (which has been debugged and work well) → need contact and eventually drawings • Russian solution as an alternative (but Ф adaptation needed) • RF and mechanical design (or modification) of 12 GHz RF valve (Ф50), and fabrication of 2 units • based on 11.4 GHz SLAC design (which has been debugged and work well) → need contact and eventually drawings • SLED2: full development (BOC solution in option) • Rectangular pumping ports and hybrid Tee have to be discussed • 3D implantation to be done quickly to evaluate the quantity of rectangular waveguides (straight and bends) and flanges • TBL: • Fabrication of 16 RF loads • CERN design or CML: → need eventually drawings to start call for tender • Purchase of 8 directional couplers (GYCOM or CML) • Fabrication of 16 waveguide bends • CLIC MODULE: • need to know which flange to be used (also for TBL and TEST STAND)