MICE is a Muon Ionization Cooling Experiment running at

MICE Particle i.d. Instrumentation D. Sanders, L. Cremaldi, D. Summers, for the MICE Collaboration Departments of Physics and Astronomy University of Mississippi. TOF1-TOF0 420 MeV/ c p +. Cherenkov Radiation in HD Aerogel. p. . simulatioonl. KL response 300 MeV/c  run. TOF0.

Télécharger la présentation

MICE is a Muon Ionization Cooling Experiment running at

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MICE Particle i.d. Instrumentation D. Sanders, L. Cremaldi, D. Summers, for the MICE Collaboration Departments of Physics and Astronomy University of Mississippi TOF1-TOF0 420 MeV/cp+ Cherenkov Radiation in HD Aerogel p  simulatioonl KL response 300 MeV/c  run TOF0 aerogel CKOV CKOV KL TOF1 Introduction TOF Beam Measurements CkOV Electron Response • MICE is a Muon Ionization Cooling Experiment running at • the Rutherford-Appleton Laboratory, Chilton UK. • Cooled muon beams will be a major technological step towards the development of a "neutrino factory" and "muon collider". • A minimum ionizing muon beam will be transversely cooled • by stages of -dE/dx in LH absorbers and longitudinal energy restoration in 201MHz RF cavities. • The 6D emittance reduction is measured before and after the cooling stage by tracking individual muons through the system. • Muon purity is assured by threeTime-of-Flight (TOF) measurements, two threshold Cherenkovs (, and a low energy muon/electron ranger KL/EMR (e. • TOFsystems tested at the Frascati test beam facility in ''07 and in place at MICE in '08. • to=55ps confirmed w good  separation in preliminary commissioning stage. 5-6 pe per pmt X 4~24 pe BC420 BC404 KL/EMR • KL/EMR - electron preshower+rear muon ranger. (KLOE - Nucl.Instrum.Meth.A598:239-243,2009) • KL- preshower constructed of 0.3mmPb+BF12 fiber • ( 2.5 Xo, E=7%/ √E, t~70ps / √E ) • EMR-70cm active scintillator w WLS+MAPMT readout ( 58bars x4s0layers = 680mm, 2360 ch ) Time of Flight System Cherenkov Particle I.d. • TOF1,2,3 - Three time of flight stations (~40cmx40cm)are positioned in the MICE channel at the start (TOF0), mid(TOF1), and rear(TOFII) positions. • Each station consists of a 10X and 10Y array constructed of BC4404/420 scintillator bar assemblies with dual R4998 PMT (30ps) readout w modified high rate HV divider. Each assembly gives typically to=55ps timing resolution. • The expected TOF resolution between 2 stations is then • TOF2 ~ 2(to/√2)2 + 2L + 2cable + 2elec ≤ 70ps2 • CKOVab- Two threshold Cherenkov detectors positively identify muons from pions in the upstream MICE beamline. • High density aerogels of n=1.12 and n=1.07 were chosen with momentum thresholds for muon I.d. between 220-360 MeV/c. Electronics Summary • PID detectors being commissioned in MICE beamline. Initial results very promisng. • Full systems operational in '09 and '10.

More Related