Client:David Beebe, Ph. DBiomedical EngineeringAdvisor:Naomi Chesler, Ph. DBiomedical Engineering. Abstract. Many running injuries are caused by continued use of improper or worn running shoes. The increase in incidence of injury can be directly correlated to the degradation of the materials used in shoe sole construction. The degree to which a shoe sole degrades is directly related to the changing elasticity of the material. Two different methods are proposed to measure elasticity in a s1144

paul2
Télécharger la présentation

team members: brant kochsiek bsac steve pauls team leader tim rand

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Team Members: Brant Kochsiek BSAC Steve Pauls Team Leader Tim Rand Communicator Brian Schwartz BWIG

    2. Client: David Beebe, Ph. D Biomedical Engineering Advisor: Naomi Chesler, Ph. D Biomedical Engineering

    3. Abstract Many running injuries are caused by continued use of improper or worn running shoes. The increase in incidence of injury can be directly correlated to the degradation of the materials used in shoe sole construction. The degree to which a shoe sole degrades is directly related to the changing elasticity of the material. Two different methods are proposed to measure elasticity in a shoe sole. Strain gauges and Flexi-Force piezoelectric force sensor devices have been added to an integrated circuit that will indirectly measure shoe sole elasticity. Once calibrated, each circuit will have a diode that lights when a shoe sole is worn past its useful life.

    4. Problem Motivation Running shoes last 300-500 miles Worn shoes do not always appear worn Incidence of injury increases with worn shoes

    5. Client Requirements Design a device that: Measures shoe sole elasticity Fits ergonomically into the shoe sole Is lightweight and small so as to not hinder performance Operable for the life of a running shoe (300-500 miles) Has a clear indicator so the runner will know when the shoe is sufficiently worn

    6. Shoe Materials Ethylene Vinyl Acetate (EVA) Polyurethane (PU)

    7. Nominal Running Style

    8. Pressure Distribution while Running

    9. Comparator/LED Differential Amplifier Drive Circuit Voltage regulator Force Sensor Circuit

    10. FlexiForce Sensors Comparison of forces from top to bottom

    11. Strain Gauge Circuit Comparator/LED Differential Amplifier Strain Gauge

    12. Strain Gauge Constant Poissons Ratio (v), Stress-Strain (d-e) for Elasticity (E)

    15. Preliminary Testing

    16. Current Standing Preliminary tests showed flaws in our circuit and sensor set up Circuit is being reworked and future testing will soon follow Research into exact placement of sensors in shoe sole is ongoing

    17. Testing Procedure Apply static loads to sensors imbedded in silicone polymer Loads applied in sets of 4000 which correlates to about a 6 mile run Following each set: Elasticity of material will be measured Output of circuit will be read from multimeter Output vs. elasticity will be plotted

    18. MTS Servohydraulic Machine We plan to use an older version of this machine found in the Materials Testing Lab in Engineering Hall

    19. Future Work Mold strain gauge into silicon mold Test both prototypes to simulate 500 miles of running wear Determine the correlation between the output of each device and elasticity Determine shoe sole wear threshold value Integrate chosen device and corresponding circuit into a shoe sole for testing Research and go through necessary human subject testing procedures Undergo human testing of the prototype shoe Possible patent application

    20. References 1000 Hz High-Cycle Fatigue Testing Systems. MTS Inc. Accessed 4/28/04 URL: http://www.mts.com/menusystem.asp?DataSource=0&NodeID=1483 Anatomy of a Running Shoe. American Running Association. Accessed: 04/26/04 URL: http://www.americanrunning.org/displayindustryarticle.com. Biomechanics Laboratory. Accessed: 04/24/04 URL: http://www.uni-essen.de/~qpd800/index.html. BTopenworld. Accessed: 04/24/04 URL: http://www.btinternet.com/~bury_rd/cheatah.jpg. FlexiForce Force Sensors. Tekscan. Accessed: 04/25/04 URL: http://www.tekscan.com/flexiforce/flexiforce.html. Forrest Gump Pictures. Cox Members High Speed Internet. Accessed 02/26/04 URL: http://members.cox.net/gumpisms/hanks1.jpg Hennig, E. M., & Milani, T. L. 1995. In-shoe Pressure Distribution for Running in Various Types of Footwear. Human Kinetics Publishers Inc., New York. Mills, N., & Verdejo, R. 2002. Performance of EVA Foam in Running Shoes. Blackwell Inc., UK, Birmingham. Runners World. Runners World. Accessed:04/27/04 URL: http://www.runnersworld.com/. Running Shoes. ePodiatry. Accessed: 04/26/04 URL: http://www.epodiatry.com/running-shoes.htm,