An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LUSICoherent X-ray Imaging InstrumentWBS 1.3 Sébastien Boutet – CXI Instrument Scientist LUSI DOE Review August 19, 2008 Team Leader: Janos Hajdu Lead Engineer: Paul Montanez, P.E. Engineer: Jean-Charles Castagna Engineer: Armin Busse Designer: Richard Jackson

  2. Outline • CXI Science • CXI Location • System Physics Requirements • System Scope • System Description • System Layout • CD-4B Deliverables • Early Science • Schedule • Costs • Major Risks • 6-month Look-ahead • Summary

  3. Science Team • Specifications and instrument concept developed with the science team. The CXI team leaders • Janos Hajdu, Photon Science-SLAC, Uppsala University (leader) • Henry Chapman, DESY, University of Hamburg • John Miao, UCLA

  4. Coherent Diffractive Imaging of Biomolecules One pulse, one measurement Particle injection LCLS pulse Wavefront sensor or second detector Noisy diffraction pattern Combine 105-107 measurements into 3D dataset Gösta Huldt, Abraham Szöke, Janos Hajdu (J.Struct Biol, 2003 02-ERD-047)

  5. Protein molecule injection LCLS detector detector To mass spectrometer X-ray diffraction pattern CXI Science • 3D bio imaging beyond the damage limit • Single injected reproducible biomolecules that can’t be crystallized • Proteins • Membrane Proteins • Viruses • Molecular complexes • Molecular machines • Biomolecular structure determination from nanocrystals • No need for large high quality crystals • 2D bio imaging beyond the damage limit • Live hydrated cells with particle injector • Nanoparticles • Quantum dots • Amorphous nanoparticles • High fluence X-ray-matter interactions • Damage studies during the pulse • Effect of tamper layers on damage

  6. CXI Instrument Location Near Experimental Hall X-ray Transport Tunnel AMO (LCLS) XPP CXI Endstation XCS Source to Sample distance : ~ 440 m Far Experimental Hall

  7. Far Experimental Hall Control Room Lab Area High Energy Density Instrument X-ray Correlation Spectroscopy Instrument Coherent X-ray Imaging Instrument

  8. CXI Physics Requirements • Goals • Perform imaging of single particles at highest spatial resolution achievable using single LCLS pulses • Image biological nanoparticles beyond the classical damage limit using single LCLS pulses • Tailor and characterize X-ray beam parameters • Spatial Profile • Intensity • Repetition rate • Deliver the sample to the beam and control its environment • Key Performance Parameters • 4-20 keV energy range • Using the fundamental and third harmonic • 0.1-0.01% energy resolution • Particle Injector • 10-1000 nm size range

  9. CXI Physics Requirements Photon Shutter Guard Slits Diagnostics Attenuators X-ray Transport Tunnel Pulse Picker Guard Slits Diagnostics Reference Laser Guard Slits Diagnostics KB Mirrors Guard Slits Diagnostics FEH Hutch 5 KB Mirrors Aperture Aperture Sample Environment Particle Injector Ion TOF-MS Detector Stage Wavefront Monitor Beam Dump

  10. CXI SCOPE - WBS 1.3

  11. CXI System Description • 1.3.1 CXI System Integration and Design • 1.3.2 CXI X-ray optics • Focusing • 2 K-B systems • 1 micron focus • 0.1 micron focus • Coherence preserving and diffraction limited • Accept the full beam • 1.3.3 CXI Laser • Reference laser • Align the experiment without the LCLS beam • 1.3.4 Coherent Imaging Injector • Focused beam of particles of varying size • Particle size range: 10-1000 nm • Remotely controlled • Steering range : 10 mm • Reentrant range: 150 mm • Particle beam diagnostics • Beam position • Beam density

  12. CXI System Description • 1.3.5 CXI Sample Environment • 1 micron Sample chamber • Vacuum better than 10 -7 torr • Sample translation stages • Aperture translation stages • Interfaces with Detector Stage. particle injector and ion TOF • Compatible with 1 micron KB system only • 1 micron instrument stand • Supports 1 micron Sample Chamber and Detector Stage • Sample diagnostics • Ion TOF mass spectrometer • Detector Stage • 50-2400 mm from sample • 0.1 micron Sample Chamber • Similar to 1 micron Sample Chamber • Compatible with 1 micron and 0.1 micron KB systems • 0.1 micron instrument stand • Supports 0.1 micron Sample Chamber, 0.1 micron KB System and Detector Stage 0.1 micron KB System

  13. CXI System Description • 1.3.6 CXI Hutch facilities • Utilities • Cabinets • 1.3.7 CXI Vacuum system • 10-7 Torr • 1.3.8 CXI Installation

  14. CXI Instrument Layout

  15. CXI Instrument Layout (X-ray Transport Tunnel) • Optics near the tunnel exit • Slits • Diagnostics • Pop-in Profile Monitors (Beam viewers) • Pop-in Intensity monitors • Intensity-Position Monitors (Non-destructive intensity monitors) • Attenuators • Pulse Picker • Reference Laser

  16. CXI Instrument Layout (FEH Hutch #5) • 2 KB systems to produce 1000 and 100 nm focus • Each KB deflects the beam and the sample chamber must move with the beam • Precision Instrument Stand holds the Sample Chamber, the Detector Stage and the 0.1 micron KB system • 10 meters of space behind sample chamber • Wavefront Monitor to characterize the focus • Used as a second detector for low q data • Diagnostics • Slits

  17. CXI Instrument Design 0.1 micron KB system Particle injector Diagnostics & Wavefront Monitor LCLS Beam 1 micron focus KB system (not shown) Sample Chamber with raster stage Detector Stage (Utilizing the LCLS Detector)

  18. CD-4B components 1 micron KB System 1 micron Sample Chamber 1 micron Precision Instrument Stand Detector Stage Common optics and Diagnostics Pulse Picker Attenuators Some slits and diagnostics CD-4C components 0.1 micron KB System 0.1 micron Sample Chamber 0.1 micron Precision Instrument Stand Particle Injector Ion Time-of-Flight Common optics and Diagnostics Remaining slits and diagnostics CD-4B CXI Instrumentation

  19. CD-4B CXI Instrumentation

  20. CD-4B CXI Science • Proof of principle imaging of test objects at diffraction limited resolution with a single LCLS shot. • 2D imaging of nanoparticles • Macromolecular structure determination from nanocrystals of proteins. • Proteins that form nanocrystals but do not form large crystals suitable for crystallography at synchrotron source. • 3D diffraction pattern built from multiple injected nanocrystals. • Relative orientation of each crystal determined from common lattice structure. • X-ray laser-matter interactions under high fluence • Measurement of damage during pulse and comparison to damage models. • Known samples on substrates • Known viruses • Calibrated nanoparticles • Damage versus fluence measurements. • Study of radiation damage mitigation techniques. • Thin tamper layers around a single molecule may slow the damage process. • Imaging of cells beyond the damage limit in 2D.

  21. CXI Schedule Preliminary Design Reviews • Detector Stage – September 2008 • Reference Laser – October 2008 • 1 micron Sample Chamber – December 2008 • Particle Injector – August 2009 • 1 micron KB System – October 2009 • 1 micron Instrument Stand – December 2009 • Ion TOF – June 2010 Final Instrument Design Review – October 2009 Final Design Reviews • Reference Laser – December 2008 • Detector Stage – May 2009 • 1 micron Sample Chamber – June 2009 • Particle Injector – December 2009 • 1 micron KB System – March 2010 • 1 micron Instrument Stand – March 2010 • Ion TOF – July 2010 Project Ready for CD-3B - October 2009 Award PO • 1 micron KB System – April 2009 • 1 micron Sample Chamber – January 2010 • Detector Stage – January 2010 • 1 micron Precision Instrument Stand – May 2010 Receive • 1 micron Sample Chamber – April 2010 • Detector Stage – June 2010 • 1 micron KB System – August 2010 • 1 micron Precision Instrument Stand – September 2010 Project Ready for CD-4B - April 2011 FY08 FY09 FY11 FY10 All dates are early finish

  22. CXI Level 3 Cost Breakdown

  23. CXI Major Risks • KB Mirror Systems • Vendor doesn’t meet specifications • Mitigation • Have SLAC quality control supervise the final fabrication process and final surface characterization • Identify vendors with proven capabilities • Delays impact other critical systems • Mitigation • Break the link between the KB0.1 mirrors and the chamber by building a second chamber to be used early with the KB1 system only • Sample Chamber • Lack of information regarding 0.1µm KB delays chamber engineering effort • Mitigation • Break the link between the KB0.1 mirrors and the chamber by building a second chamber to be used early with the KB1 system only • Particle Injector • Remote operation • Mitigation • Leverage institutional efforts to solve this problem • Move injector to a CD-4C deliverable to relieve schedule risk

  24. 6-month Look-ahead • 6 month “look-ahead” at Level 4/5 Milestones • ESDs released • CXI Detector Stage – Sept 08 • CXI Reference Laser – Sept 08 • CXI 1.0µm KB System – Sept 08 • CXI 1.0µm Precision Instrument Stand – Sept 08 • CXI 1.0µm Sample Chamber – Oct 08 • CXI 0.1µm KB System – Oct 08 • PRDs released • CXI Injector – Jan 09 • Preliminary Design Reviews • CXI Detector Stage – Sept 08 • CXI Reference Laser – Oct 08 • CXI Vacuum Equipment – Nov 08 • CXI 1.0µm Sample Chamber – Dec 08 • Final Design Reviews • CXI Reference Laser – Dec 08 • Vacuum System Equipment – Jan 09 • Cornell Detector Packaging (Participate in) – Feb 09 • Vendor Related • Release CXI KB Systems RFP – Jan 09 • Receive CXI KB Systems Vendor Proposals – Feb 09 • Far Experimental Hall Hutches • FEH H5 Preliminary Layout – Sept 08 • LCLS 30%, 60%, 90% hutch drawing review – Sept 08, Oct 08 and Jan 09 • LCLS FEH FDR – Jan 09

  25. Summary • Instrument accommodates a wide variety of cutting edge research capabilities and fulfills the CD-0 mission • Instrument concept is based on proven developments made at FLASH and SR sources • Safety hazards have been identified in the Hazard Analysis Report (HAR) • Safety issues are considered at every step of the design and fabrication process • Scope of instrument fully defined • Resource loaded schedule developed through end of project • Preliminary design of key components is well advanced • CXI and LUSI are ready for CD-2 approval