1 / 1

Momentum Corrections for E5 Data Set R. Burrell, G.P. Gilfoyle

Introduction The Thomas Jefferson National Accelerator Facility (JLab) in Newport News, Virginia, is used to understand the fundamental properties of matter in terms of quarks. We describe here how data is collected at Jefferson Lab and how to improve the measurement of the electron momenta.

Télécharger la présentation

Momentum Corrections for E5 Data Set R. Burrell, G.P. Gilfoyle

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introduction The Thomas Jefferson National Accelerator Facility (JLab) in Newport News, Virginia, is used to understand the fundamental properties of matter in terms of quarks. We describe here how data is collected at Jefferson Lab and how to improve the measurement of the electron momenta. Results Below we show results for MM2 and W2 for 2.56 GeV, reversed field and 4.23 GeV, normal field running conditions before and after the correction. Momentum Corrections for E5 Data Set R. Burrell, G.P. Gilfoyle University of Richmond, Physics Department CEBAF The Continuous Electron Beam Accelerating Facility(CEBAF) is the central particle accelerator at JLab. CEBAF is capable of producing electron beams of 2-6 GeV. The accelerator is about 7/8 of a mile around and is 25 feet underground. The electron beam is accelerated through the straight sections and magnets are used to make the beam travel around the bends(See Fig. 1). An electron beam can travel around the accelerator up to five times at the speed of light. The beam is sent to one of three halls where the beam collides with a target and causes particles to scatter into the detectors. Physics Motivation The CLAS detector is a large (10 m diameter, 45 ton) spectrometer designed to measure and identify the debris from a nuclear collision. A toroidal magnet field bends the trajectories of charged particles through CLAS and enables us to measure their momenta. Improving the accuracy and precision of those measurements is the goal of this project. There are many small deviations within CLAS. These include things like wire misalignments, imperfect knowledge of the magnetic field, and wire sag, among others. Despite these imperfections, we are able to measure the angle at which particles are scattered quite precisely. These angles provide a more accurate depiction of the momentum under the appropriate conditions. Fig. 5. Corrected missing mass 2.56 GeV Fig. 6. Corrected W2 vs φe for 4.23 GeV Procedure (1) In an e + p  e’ + π+ + X reaction, we detect the scattered electron and pion, and use conservation laws to determine missing mass (MM2) of X. We then compare this value with the known mass of a neutron. The momentum corrections for this set of data should move the peak in this missing mass plot closer to the accepted, known value. It should also make the peak narrower (more precise), and should even out sector by sector variations. We use this method of detecting two particles and calculating the third because it is much easier than detecting three particles at once. Table 1. Centroid and width of uncorrected and corrected missing mass for 4.23 GeV Hall B Table 2. Centroid and width of uncorrected and corrected W2 vs φe for 4.23 GeV Fig.4. Profile Histogram of ΔqB/p vs. qB/pc with fitted line. Fig. 1 JLab Accelerator and Halls A, B, and C CLAS The CEBAF Large Acceptance Spectrometer(CLAS), located in Hall B, is used to detect electrons, protons, pions and other subatomic particles. CLAS is able to detect most particles created in a nuclear reaction, because it covers a large range of angles. The particles go through each region of CLAS leaving behind information that is collected and stored on tape. The event rate is high (about 3000 Hz), so the initial data analysis is done at JLab, and we analyze more deeply those results at the University of Richmond. There are six different layers of CLAS, visible in Figure 2, that produce electrical signals that provide information on velocity, mass, and energy, and allows us to identify and separate different subatomic particles. The drift chambers make up the first three layers, and determine the path of different particles. Also in CLAS is a toroidal magnet that causes charged particles to bend as they pass through the drift chambers. This bending is then used to determine momentum, which leads to a calculation of mass that is used to identify the particle[1]. Procedure (3) From these total 384 histograms, a profile histogram is constructed for each bin. A profile histogram makes slices along the x-axis and displays the mean y-value and standard deviation within that slice. These profile histograms are then fitted with a first order polynomial (see Fig. 4). Procedure (2) First we calculate curvature, qB/pm, event by event, where q is particle charge, B is the ratio of the torus current to 3860A, and pm is the reconstructed particle momentum. We then calculate the curvature again using pc, which is derived only from the polar angle of the track, θ. We then separate events into 16 Θe bins and 24 φe bins. Next, we make a 2-dimensional plot of the difference between these two curvatures and qB/pc for each Θe- φe bin (See Fig. 3). Fig. 7. Corrected missing mass for 2.56 GeV Fig. 8. Corrected W2 vs φe for 2.56 GeV Procedure (4) The parameters from this fit, α (slope) and β (y-intercept) are then inserted into the equation: ΔqB/p = α + β(qB/pc) And we solve for pc, which becomes the corrected momentum. We then use this to calculate the corrected missing mass. Table 3. Centroid and width of uncorrected and corrected missing mass for 2.56 GeV Table 4. Centroid and width of uncorrected and corrected W2 vs φe by sector for 2.56 GeV Procedure (5) As an addition test of the accuracy and precision of this procedure we also compared W2 (the square of the recoiling mass for e + p  e’ + X) before and after applying the momentum corrections for the electron. Conclusion We find the uncorrected data was already quite accurate and this procedure did little to improve the peak position or width. Fig. 2 CLAS Event Display(CED), displays signals received from each layer of CLAS. Fig. 3. 2D Histogram of ΔqB/p vs. qB/pc .

More Related