1 / 37

Samsung Electronics

PBA Repair Guide [SGH-I900]. Samsung Electronics. Contents. 1. PBA Diagram 2. Trouble Shooting 2-1. No Power 2-2. Lockup / Reset 2-3. SIM Card Failed 2-4. Camera Failed 2-5. No Vibration 2-6. Bluetooth Searching Failed 2-7. No Charging 3. Appendix

saburo
Télécharger la présentation

Samsung Electronics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PBA Repair Guide [SGH-I900] Samsung Electronics

  2. Contents 1. PBA Diagram 2. Trouble Shooting 2-1. No Power 2-2. Lockup / Reset 2-3. SIM Card Failed 2-4. Camera Failed 2-5. No Vibration 2-6. Bluetooth Searching Failed 2-7. No Charging 3. Appendix 3-1. How to check the voltage and frequency

  3. 1. PBA Diagram SGH-I900 • TOP

  4. 1. PBA Diagram SGH-I900 • Bottom

  5. 2-1. No Power (PDA) SGH-I900 • Trouble shooting C668 = 3V C665, C674 = 1.8V C667, C677 = 2.6V Y Y Y Input the power (3.8V) Power-on-current >= 100mA U304 P1 = 4V Check UCP600 N N N Download S/W (PDA) Check U304 Check U605 ※ It’s a general case. It cannot be available on the special case.

  6. 2-1. No Power (PDA) SGH-I900 Input the power 3.8V 2. Check the power-on-current >= 100mA - If not : Download PDA software (refer to 2-2. Lockup/Reset) 3. Check the voltage U304 Pin number 1 = 4V - If not : Check the U304 (crack, open, short, etc) 4. Check the Voltage 1) C668 = 3V 2) C665, C674 = 1.8V 3) C667, C677 = 2.6V - If not : Check the U605 (crack, open, short, etc) 5. There is no problem from 1 to 4, check the UCP600

  7. 2-1. No Power (PDA) SGH-I900 Picture 2-1-3, 2-1-4, 2-1-5 UCP600 ● 1 C677 ● U605 U304 ● ● C668 ● ● C667 C674 C665

  8. 2-1. No Power (PDA) SGH-I900 Scope 2-1-3, 2-1-4 4V 3V

  9. 2-1. No Power (PDA) SGH-I900 Scope 2-1-4 1.8V 1.4V

  10. 2-1. No Power (Phone) SGH-I900 • Trouble shooting Y Y Y Input the power (3.8V) Power-on-current >= 100mA U201 P2 = 1.8V D300 P2 = 1.8V N N N Download S/W (Phone) Check U201 Check UME201 Y Y Check U301 D300 P3 = 1.8V OSC102 = 32kHz N N Check OSC102 or UCP600 Check D300 ※ It’s a general case. It cannot be available on the special case.

  11. 2-1. No Power (Phone) SGH-I900 Input the power 3.8V 2. Check the power-on-current >= 100mA - If not : Download Phone software (refer to 2-2. Lockup/Reset) 3. Check the voltage 1) U201 Pin number 2 = 1.8V (Low) - If not : Check the U201 (crack, open, short, etc) 2) D300 Pin number 2 = 1.8V (Low) - If not : Check the UME201 (crack, open, short, etc) 3) D300 Pin number 3 = 1.8V (Low) - If not : Check the D300 (crack, open, short, etc)

  12. 2-1. No Power (Phone) SGH-I900 4. Check the OSC102 = 32kHz - If not : Check the OSC102 or UCP600 5. If there is no problem from 1 to 4, check the U301 (crack, open, short, etc)

  13. 2-1. No Power (Phone) SGH-I900 Picture 2-1-3, 2-1-4, 2-1-5 UCP600 2, 3 ● ● D300 UME201 OSC102 U201 ● 2

  14. 2-1. No Power (Phone) SGH-I900 Scope 2-1-3, 2-1-4 32kHz 1.8V

  15. 2-2. Lockup / Reset SGH-I900 • Trouble shooting Lockup/Reset (Omnia screen) Use a PDA J-TAG Check UCP600 (PDA) Check UCP600 (PDA) Download the latest PDA S/W N Y Y Download Completed Lockup or reset (Same as declared) N N Download the latest Phone S/W Repeat the lockup/reset test Check UME200 (Phone) Check UCP200 (Phone) Lockup/Reset (Phone off after power on) Use a Phone J-TAG ※ It’s a general case. It cannot be available on the special case.

  16. 2-2. Lockup / Reset SGH-I900 Use a J-TAG to enable USB - Lockup/Reset on Omnia screen : Use a PDA J-TAG - Phone off after power on : Use a Phone J-TG 2. Download the latest software - If download is not completed : Check the UCP600 (PDA) (crack, open, short, etc) : Check the UME200 (Phone) (crack, open, short, etc) Picture 2-2-2 UME200 UCP600 UCP200

  17. 2-2. Lockup / Reset SGH-I900 - If download is completed but it still has the same defect : Check the UCP600 (PDA) (crack, open, short, etc) : Check the UCP200 (Phone) (crack, open, short, etc) - If download is completed and you cannot find the same defect : Repeat the lockup/reset test declared originally

  18. 2-3. SIM Card Failed SGH-I900 • Trouble shooting N Pin 1, 2, 4 = 3V Pin 3 = 3V Clock Check the 6-pins of SIM socket Input the power (3.8V) There is durst or damaged Y N Clean or change SIM socket Check U301 or UCP200 ※ It’s a general case. It cannot be available on the special case.

  19. 2-3. SIM Card Failed SGH-I900 Check the 6-pins of SIM socket - If there is a durst : Clean the pins - If it is damaged : Change the SIM socket 2. Input the power 3.8V 3. Check the voltage 1) Pin number 1, 2, 4 = 3V 2) Pin number 3 = 3V Clock - If not : Check the U301 or UCP200 (crack, open, short, etc) ※ Check the voltage when you input the power on the PBA. Picture 2-3-3 1 2 3 ● ● ● ● 4

  20. 2-3. SIM Card Failed SGH-I900 Scope 2-3-3 3V Clock 1.9V Clock 3V 1.9V

  21. 2-4. Camera Failed SGH-I900 • Trouble shooting There is durst or damaged N Y Check HDC500 U512 P3 = 3V C535 = 1.2V Y N N Clean or Change HDC500 Check UCP600 Check U512 ※ It’s a general case. It cannot be available on the special case.

  22. 2-4. Camera Failed SGH-I900 Check the HDC500 - If there is a durst or damaged : Clean or change the HDC500 2. Connect a camera and input the power 3.8V 3. Check the voltage U512 Pin number 3= 3V - If not : Check the UCP600 (crack, open, short, etc) 4. Check the voltage C535 = 1.2V - If not : Check the U512 (crack, open, short, etc) ※ Check the voltage during camera entering mode. - LCD, TSP and camera must be connected to PBA. - Input the power and press key number *#0*# → 7

  23. 2-4. Camera Failed SGH-I900 Picture 2-4-3, 2-4-4 HDC500 UCP600 U512 ● 3 ● C535

  24. 2-4. Camera Failed SGH-I900 Scope 2-4-3, 2-4-4 3V 1.2V

  25. 2-5. No Vibration SGH-I900 • Trouble shooting Connect a motor Input the power Vibration on There is durst or damaged N Check the HDC500 U510 P1 = 3V C541 = 3V Y N N Clean or Change HDC500 Check U609 Check U510 ※ It’s a general case. It cannot be available on the special case.

  26. 2-5. No Vibration SGH-I900 Check the HDC500 - If there is a durst or damaged : Clean or change the HDC500 2. Connect a motor, input the power (3.8V), Vibration on 3. Check the voltage U510 Pin number 1 = 3V - If not : Check the U609 (crack, open, short, etc) 4. Check the voltage C541 = 3V - Check the U510 (crack, open, short, etc) ※ Check the voltage during vibrating. - LCD, TSP and vibrator must be connected to PBA. - Input the power and press key number *#0*# → 5

  27. 2-5. No Vibration SGH-I900 Picture 2-5-1, 2-5-3, 2-5-4 Scope 2-5-3, 2-5-4 HDC500 U609 3V U510 1 ● ● C541

  28. 2-6. Bluetooth Searching Failed SGH-I900 • Trouble shooting Input the power Bluetooth on Search devices Check L119, ANT103 N Y There is problem (crack, open) U101 P6 = 3.3V U101 P5 = 1.8V Y N Resolder or change Check U101 Y OSC101 = 26MHz Check MOD100 N Check OSC101 ※ It’s a general case. It cannot be available on the special case.

  29. 2-6. Bluetooth Searching Failed SGH-I900 1. Check the L119, ANT103 (crack, open, etc) - If there is a problem : Resolder or change it 2. Input the power (3.8V), Bluetooth on, Search devices 3. Check the voltage U101 Pin number 6 = 3.3V, Pin number 5 = 1.8V - If not : Check the U101 (crack, open, short, etc) 4. Check the clock OSC101 = 26MHz - If not : Check the OSC101 (crack, open, short, etc) 5. If there is no problem from 1 to 4, check the MOD100 (crack, open, short, etc)

  30. 2-6. Bluetooth Searching Failed SGH-I900 ※ Check the voltage during searching devices - LCD and TSP must be connected to PBA. - Insert a SIM card and input the power. - Activate on the bluetooth and search devices.

  31. 2-6. Bluetooth Searching Failed SGH-I900 Picture 2-6-1, 2-6-3, 2-6-4, 2-6-5 U101 ● ● 5,6 MOD100 OSC101 L119 ANT103

  32. 2-6. Bluetooth Searching Failed SGH-I900 Scope 2-6-3 3.3V 1.8V

  33. 2-6. Bluetooth Searching Failed SGH-I900 Scope 2-6-4 26MHz

  34. 2-7. No Charging SGH-I900 • Trouble shooting Connect TA to the power supply Y Y Input the power (5V) Current = 400 ~ 600mA U303 P10 = 5V Check UCP600 N N Check U303 or IFC400 Check U301 ※ It’s a general case. It cannot be available on the special case.

  35. 2-7. No Charging SGH-I900 Connect TA to the power supply and input the power (5V) 2. Insert a TA to PBA 3. Check the current = 400 ~ 600mA - If not : Check the U301 (crack, open, short, etc) 4. Check the voltage U303 Pin 10 = 5V - If not : Check the U303 or IFC400 5. If there is no problem from 1 to 4, check the UCP600 (crack, open, short, etc) ※ Check the voltage during charging. - TA can be connected to power supply must be prepared. Picture 2-7-1, 2-7-2 TA Insert to PBA

  36. 2-7. No Charging SGH-I900 Picture 2-7-4, 2-7-5 Scope 2-7-4 U301 UCP600 U303 ● 10 IFC400 5V

  37. 3-1. How to check the voltage and frequency • Equipment : Oscilloscope (Bandwidth : more than 500MHz) • PBA condition : Power on by using power supply • Ground the scope • Put a scope to the point you want to check Input the power Ground Put a scope

More Related