Explore the behavior of beam calorimeter tiles with electron beams of 500MeV and repetition rate of 50Hz. Analyze pulse duration, current per pulse, and electronic rate to understand linearity and particle contributions. Utilize CAMAC acquisition system for data collection and examine voltages for S1, T1, T2, and S2. Investigate ADC readings and linearity for different scenarios with varying particle multiplicities. Gain insights into tile behavior based on power voltages adjustments.
E N D
Data analysis BTF 23 e 24 mag 05 S2 T2 S1 T1 Beam Calo T1 • 500MeV electrons • Repetition Rate 50 Hz • Pulse Duration 1-10 ns • Current/pulse 1 to 8 particles • σXY~2mm • Max Electronic Rate: 1KHz T2 CAMAC acquisition system
File 240505_2200, 35000events • Voltages • S1: 880mV • T1: 66.5 V • T2: 64.9 V • S2: 900mV
calorimeter Countings ADC readings
1e- contribution ADC readings
2e- contribution ADC readings
3e- contribution ADC readings
Linearity • Voltages • S1: 880mV • T1: 66.5 V • T2: 64.9 V • S2: 900mV
File 240505_1830, 17000events • Voltages • S1: 880mV • T1: 66.9V • T2: 65.3V • S2: 900 mV
calorimeter Countings ADC channels
S2 T2 T1 S1 Calo 1e- contribution ADC readings
S2 T2 T1 S1 Calo 2e- contribution ADC readings
S2 T2 T1 S1 Calo 3e- contribution ADC readings
Linearity • Voltages • S1: 880mV • T1: 66.9V • T2: 65.3V • S2: 900 mV
File 250505_0831, 80000events • Voltages • S1: 890mV • T1: 67.1V • T2: 65.5 V • S2: 900mV
calorimeter Countings ADC channels
1e- contribution ADC readings
2e- contribution ADC readings
3e- contribution ADC readings
Linearity • Voltages • S1: 890mV • T1: 67.1V • T2: 65.5 V • S2: 900mV
T1&T2 vs power voltages Behavior of the tiles in function of the tension for three different particle multiplicity