1 / 76

QSAR Application Toolbox: Third Step - Data Gap Filling (Read-Across by Molecular Similarity)

QSAR Application Toolbox: Third Step - Data Gap Filling (Read-Across by Molecular Similarity). Background.

Télécharger la présentation

QSAR Application Toolbox: Third Step - Data Gap Filling (Read-Across by Molecular Similarity)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. QSAR Application Toolbox:Third Step - Data Gap Filling(Read-Across by Molecular Similarity)

  2. Background • This is a step-by-step presentation designed to take the you through the workflow of the Toolbox in a data-gap filling exercise using read-across based on molecular similarity with data pruning. • If you are a novice user of the Toolbox you may wish to review the “Getting Started” document available at [www.oecd.org/env/existingchemicals/qsar]

  3. Objectives-1 • This presentation reviews a number of functionalities of the Toolbox : • Entering and Profiling a target chemical, • Identifying analogues for a target chemical, • Retrieving experimental results available for those analogues, and • Filling data gaps by read-across.

  4. Objectives-2 • This presentation also introduces several other functionalities of the Toolbox : • Use of the Flexible Track • Entering a target chemical by SMILES notation, • Identify analogues for a target chemical by molecular similarity, • Retrieve experimental results for multiple endpoints

  5. Specific Aims • To review the work flow of the Toolbox. • To review the use of the six modules of the Toolbox. • To review the basic functionalities within each module. • To introduce the user to new functionalities with selected modules • To explain to the rationale behind each step of the exercise.

  6. The Exercise • In this exercise we will predict the Ames mutagenicity potential for an untested compound, (n-hexanal) [SMILES CCCCCC=O)], which is the “target” chemical. • This prediction will be accomplished by collecting a small set of test data for chemicals considered to be in the same category as the target molecule. • The category will be defined by molecular similarity, in particular “Organic functional groups”. • The prediction itself will be made by “read-across”.

  7. Read-across & the Analogue Approach • Read-across can be used to estimate missing data from a single or limited number of chemicals using an analogue approach. • In the analogue approach, endpoint information for a single or small number of tested chemicals is used to predict the same endpoint for an untested chemical that is considered to be “similar.”

  8. Analogous Chemicals • Previously you learned that analogous sets of chemicals are often selected based on the hypothesis that the toxicological effects of each member of the set will show a common behavior. • For this reason mechanistic profilers and grouping methods have been shown to be of great value in using the Toolbox. • However, there are cases where the mechanistic profilers and grouping methods are inadequate and one is forced to rely on molecular similarity to form a category. • The Toolbox allows one to develop a category by using either organic functional groups or structural similarity. • Since there is no preferred way of identifying structural similarity the user is guided to use organic functional groups as a first option.

  9. Side-Bar On Mutagenesis • Mutagens do not create mutations. • Mutagens create DNA damage. • Mutations are changes in nucleotide sequence. • Mutagenesis is a cellular process requiring enzymes and/or DNA replication, thus cells create mutations.

  10. Tracks • After opening the Toolbox, the user has to choose between three use tracks (or workflows): • (Q)SAR Track • Category Track • Flexible Track • Since you are becoming more familiar with the functionalities of the Toolbox, select the Flexible Track.

  11. Tracks and Workflow

  12. Workflow • Remember each track follows the same workflow: • Chemical Input • Profiling • Endpoints • Category Definition • Filling Data Gaps • Reporting

  13. Chemical Input • Click on the “Flexible Track”. • This takes you to the first module, which is “Chemical input”. • This module provides the user with several means of entering the chemical of interest or the target chemical. • Since all subsequent functions are based on chemical structure, the goal here is to make sure the molecular structure assigned is the correct one.

  14. Chemical Input Screen

  15. Ways of Entering a Chemical • Remember there are several ways to enter a target chemical and the most often used are: • CAS#, • SMILES (simplified molecular information line entry system) notation, and • Drawing the structure. • Click on SMILES. • This inserts the window entitled “Structure editor” (see next slide).

  16. Blank Structure Editor Screen

  17. Entering a SMILES • In the Aqua-colored area type in the SMILES; in this example enter CCCCCC=O • Note as you type the SMILES code the structure is being drawn in the center of the field (see next slide). • Click “OK” to accept the target chemical.

  18. SMILES & STRUCTURE

  19. Target Chemical • You have now selected your target chemical. • Click on the box next to “Substance Information”; this displays the chemical identification information. • It is important to remember from here on the workflow will be based on the structure coded in SMILES. • The workflow on the first module is now complete; click “Profiling” to move to the next module.

  20. Chemical Identification Information

  21. Profiling • “Profiling” refers to the electronic process of retrieving relevant information on the target compound, other than environmental fate, ecotoxicity, and toxicity data, which are stored in the Toolbox. • Available information includes likely mechanism(s) of action and a survey of organic functional group, which form the target chemical.

  22. Profiling Target Chemical • Select the “Profiling methods” you wish to use by red-checking the box before the name of the profiler you wish to use. • For this example, select all the profilers for the “mechanistic” methods (see next slide). • Click on “Apply”.

  23. Profilers for 1-Hexanal

  24. Profiling • The results of profiling automatically appear as a dropdown box under the target chemical (see next slide).

  25. Profiles of 1-Hexanal (1)

  26. Profiles of 1-Hexanal (2) • Very specific profiling results are obtained for the target compound. • Please note that no DNA-binding mechanisms was identified (see side-bar on mutagenicity above). • These results will be used to search for suitable analogues in the next steps of the exercise.

  27. Side-Bar on the Data Tree • As one moves through the different modules of the workflow the information on the target chemical increases. • One may find it advantageous to conceal some of that information. • For example we can hide the substance information by double clicking on the -

  28. Side-Bar on Retrieving Concealed Information • One can retrieve hidden information by double clicking on the • This is demonstrated in the next two slides. +

  29. Double click on small box next to substance information

  30. Substance informationreappears on screen

  31. Endpoints • Click on “Endpoints” to move to the next module. • “Endpoints” refer to the electronic process of retrieving the environmental fate, ecotoxicity and toxicity data that are stored in the Toolbox. • Data gathering can be executed in a global fashion (i.e., collecting all data of all endpoints) or on a more narrowly defined basis (e.g., collecting data for a single or limited number of endpoints).

  32. Side-Bar on Gene Mutation • Mutations within a gene are generally base-substitutions or small deletions/insertions (i.e., frameshifts). • Such alteration are generally called point mutations. • The Ames scheme based on strains of Salmonella provide the corresponding experimental data.

  33. This Example • In this example, we focus our data gathering to the-multi-endpoint of mutagenicity and the databases OASIS Genotox and ISSCAN. • Click on the boxes next to all the databases except those entitled “ISSCAN Gentox” and “OASIS Genotox”. • This leaves a black check mark in the box next to these two database (the ones we want to search). • Click on “Gather data”.

  34. Oasis Genotox Data Gathering

  35. Next Step in Data Gathering • Toxicity information on the target chemical is electronically collected from the selected dataset(s). • In this example, an insert window appears stating there was “no data found” for the target chemical (see next slide). • Close the insert window.

  36. No data for Target Chemical

  37. Recap • You have entered the target chemical by SMILES and found it to be 1-hexanal with the CAS# [66-25-1]. • You have profiled the target chemical and found no experimental data is currently available for 1-hexanal. • In other words, you have identified a data gap, which you would like to fill. • Click on “Category definition” to move to the next module.

  38. Category Definition • This module provides the user with several means of grouping chemicals into a toxicologically meaningful category that includes the target molecule. • This is the critical step in the workflow. • Several options are available in the Toolbox to assist the user in refining the category definition.

  39. Grouping Methods • Allow the user to group chemicals into chemical categories according to different measures of “similarity” so that within a category data gaps can be filled. • For example, starting from a target chemical for which a specific DNA binding mechanism is identified, analogues can be found which can bind by the same mechanism and for which experimental results are available.

  40. Side-Bar on Mutagens • It is important to remember that mutagens are really cell-damaging agents, which can create a wide array of adverse effects beyond damage to DNA. • Lets take a moment to review our mechanistic profile of the target chemical (see next slide).

  41. No DNA Binding

  42. Defining the Category • In the case of 1-hexanal there is no structural evidence that it is a DNA binding compound. • Therefore, no grouping by a DNA mechanism is possible. • We elect to define the category by using molecular similarity. • Highlight “Organic functional groups”. • Click on “Defining Category”.

  43. Defining the Category

  44. Confirmation of Groups • An insert window listing the organic function groups of the target chemical appears. • Click on “OK”.

  45. Naming Category • Another insert window listing the default category name appears. • Click “OK”.

  46. Analogues Identified

  47. Recap • You have identified a structurally similar category for the target chemical (1-hexanal). • There were 34 similar chemicals identified. • Available data on these similar chemicals can now be collected.

  48. Next Step in Gathering Data • Highlight the “[35]Aldehydes <AND>Methyl …” under “Single Chemical” in the “Defined Categories” box. • The inserted window entitled “Read Data?” appears (see next slide).

  49. What data to collect?

  50. Side-Bar to Data Collection • Data can be collected for a wide variety of endpoints or for narrowly defined (e.g., endpoint, test scheme) ones. • Since data is endpoint specific the data selection is presented in a drop-down menu. • By double clicking on an endpoint, the data tree is expanded.

More Related