1 / 24

What happens when Wind /Solar do not meet requirements? What next?

What happens when Wind /Solar do not meet requirements? What next?. Current solutions Duel Generators Diesel – Battery Hybrid DC Generators. TESUCO TELECOMMUNICATIONS OFFERS “HYGEN” ADVANCED ENERGY SYSTEMS THROUGH POWER ELECTRONICS !. FEATURES:

shona
Télécharger la présentation

What happens when Wind /Solar do not meet requirements? What next?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Confidential & Proprietary

  2. What happens when Wind /Solar do not meet requirements? What next?

  3. Current solutions • Duel Generators • Diesel – Battery Hybrid • DC Generators

  4. TESUCO TELECOMMUNICATIONS OFFERS “HYGEN” ADVANCED ENERGY SYSTEMS THROUGH POWER ELECTRONICS !

  5. FEATURES: • Low Emissions and Environment Friendly • Low Fuel Consumption • Low Operating Costs • Low Life Cycle Costs • Longer Engine Life • High Quality Power • Impervious to Voltage Distorting Loads • Adaptable to Real World Load Profiles through Variable Speed Operation • Capable of operating under light load conditions without sustaining damage • Modular System Architecture • Programmable Power Flow and Source Loading • Compact and lightweight • Averts Over sizing through Variable Speed Operation – Rightsizing Confidential & Proprietary

  6. HYGEN POWER SYSTEM ENERGY STORAGE MICRO HYDRO GAS/DIESEL ENGINE GRID SOLAR WIND 1 kW - 1 MW POWER ELECTRONIC CONVERTER ON-SITE POWER GENERATION POWER FACTOR CORRECTION HARMONIC FILTERING PEAK SHAVING UPS A PATENTED TECHNOLOGY FOR ADVANCED POWER MANAGEMENT !

  7. HYGEN “GREEN” POWER REDUCED FOSSIL FUEL REQUIREMENTS REDUCED EXHAUST EMISSIONS RECYCLABLE END-OF- LIFE-CYCLE MATERIALS LOW NOISE EMISSIONS CONFORMING TO EURO2/3/4 STANDARDS Confidential & Proprietary TODAY’S ECO-FRIENDLY SOLUTION UNTIL GREENER FUELS ARE REALISED !

  8. Constant Speed Genset size ON-SITE GENERATION : THE PROBLEM PLD = Peak Load Demand Load demand [kW] ALD = Average Load Demand

  9. ON-SITE GENERATION : THE PROBLEM PLD = Peak Load Demand 9 8 Load demand [kW] 7 6 Min Load Threshold Allowed By engine Manufacturer (50% of Generator Capacity) 5 4 Light Loading 3 2 1 Time (24 hrs)

  10. ON-SITE GENERATION : THE PROBLEM 9 8 Load demand [kW] 7 6 Dummy Load Profile 57% Average 5 4 Wasted Fuel Normal Load Profile 32% Average 3 2 1 Time (24 hrs)

  11. 5 4.5 Min Load Threshold (50% of Capacity) 4 3.5 3 Fuel consumption [l/h] FUEL EFFICIENCY OF HYGEN COMPARED TO OTHER TECHNOLOGIES 2.5 2 ALD Fuel Consumption 1.5 Normal Generator VSG Generator 1 Hygen Generator 0.5 0 1 2 3 4 5 6 7 8 9 Load [kW]

  12. Battery power Battery power 9 8 7 6 5 Load [kW] 4 3 80% 40% 2 1 Time (24 hrs) THE SOLUTION Power [kW] 50 Hz Engine speed Confidential & Proprietary

  13. 1 kW dummy load 0 kW dummy load 2 kW dummy load 3 kW dummy load 58% 51% 42% 32% 34 litres/day 40 litres/day 29 litres/day 44 litres/day 79 litres/day 69 litres/day 66 litres/day 75 litres/day FUEL COMPARISON: FUEL SAVING : VS 35.7 litres/day Confidential & Proprietary

  14. THE HYGEN SYSTEM IGBT CONVERTER INVERTER RECTIFIER PM DC-DC ENGINE 230V ALTERNATOR CONVERTER 50Hz S N BATTERY CONTROL Confidential & Proprietary

  15. SYSTEM LAYOUT – MECHANICAL CONSTRUCTION

  16. DESIGNED FOR HIGH MOBILITY • Transportable by Air, Sea, Road and Rail • Extremely compact in relation to power output • Easy to load and offload • Physical size approximately 20% of comparable conventional units • Can be transported in medium size aircraft, • Can be airlifted by medium type helicopters for rapid deployment • Fits inside standard ISO container • Can be installed in one end of container – no rear access required

  17. WHY HYGEN? • Smaller • Lighter • Modular • Reliable • Efficient • Economic • Environmentally Friendly • Multiple Energy Source Control

  18. Differentiating Feature Unique “Decoupling Method” Variable Speed Generators + Load adaptive capability • Up to 40% Fuel efficiency compared to conventional systems • Dynamically Stable under onerous load conditions • High Quality Electrical output under all load conditions • Optimum Engine utilization

  19. HYGEN Remote Monitoring System Confidential & Proprietary

  20. HYGEN MONITORING SYSTEM INFORMATION ISKNOWLEDGE AND KNOWLEDGE IS POWER! Confidential & Proprietary

  21. HYGEN MONITORING SYSTEM ENERGY STORAGE GRID SOLAR WIND MICRO HYDRO GAS/DIESEL ENGINE MONITORING HUB ACCESS CONTROL FIRE ALARM ENGINE RPM FUEL LEVEL TEMPERATURE OIL PRESSURE VOLTAGE SENSING CURRENT SENSING Confidential & Proprietary CONVERTING SENSOR SIGNALS INTO INFORMATION !

  22. HYGEN MONITORING SYSTEM CURRENT SENSING ACCESS CONTROL VOLTAGE SENSING SCHEDULED MAINTENANCE OIL PRESSURE HUMIDITY FIRE ALARM RPM FUEL LEVEL TEMPERATURE AIRFLOW EXPANDING THE SYSTEM TO MONITOR BUILDINGS ! Confidential & Proprietary

  23. HYGEN IS YOUR COMPLETE GREEN POWER GENERATION SYSTEM • TESUCO HYGEN POWER System, is a hybrid electricity generator and on-site power supply system which combines generators with power electronics and computer control. • The outcome is a unique electric power production and management system for on-site applications. • Hygenis a new generator technology that is independent, smaller, lighter, reliable, efficient, economic and environmentally friendly, and that can produce high quality electric power under today’s real world load conditions.

  24. THANK YOU Confidential & Proprietary

More Related