1 / 22

Correcting Tracings for the Lumbo-Sacral A-P Control LSO

Correcting Tracings for the Lumbo-Sacral A-P Control LSO. Correcting Tracings. Given tracings and an orthometry form you will prepare a “blueprint” to be used when fabricating the LSO. Correcting Tracings. You will begin by correcting the pelvic and thoracic bands. Correcting Tracings.

sinead
Télécharger la présentation

Correcting Tracings for the Lumbo-Sacral A-P Control LSO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Correcting Tracings for the Lumbo-Sacral A-P Control LSO

  2. Correcting Tracings • Given tracings and an orthometry form you will prepare a “blueprint” to be used when fabricating the LSO

  3. Correcting Tracings • You will begin by correcting the pelvic and thoracic bands

  4. Correcting Tracings • Both bands are corrected the same way so begin with the pelvic band

  5. Determining Band Lengths • Locate the circumference of the pelvis at the ASIS level on your orthometry form • Divide that number in half Example: 35¸2=17 1/2 ¸

  6. Determining Band Lengths • If the original circumference is 36” or under, add 1-1/2” to the result of the divided circumference to determine the corrected length of your band Example: 35”¸2 = 17 1/2” 17 1/2” + 1 1/2”=19” ¸

  7. Determining Band Lengths • If the original circumference is over 36”, add 2” to the result of the divided circumference to determine the corrected length of your band Example: 39”¸2=19 1/2” 19 1/2” + 2”=21 1/2” ¸

  8. Adjusting Band Tracing • Divide the corrected length in half • Using a flexible tape measure following the traced line, measure the resultant distance from the center line to both ends of the tracing and mark

  9. Adjusting Band Tracing • Connect those marks with a straight line (transverse line) • Using a 90 triangle, draw a line perpendicular to the transverse line through the original center line

  10. 2” 2” Adjusting Band Tracing • Hold a ruler at 90 degrees to the adjusted center line and slide it down the line until the 2” mark just touches the curved tracing on both sides • Mark the points at which the rule touches the tracing

  11. 2” 2” Adjusting Band Tracing • Draw a line across the tracing at that position.

  12. Adjusting Band Tracing • Draw a line across the tracing at that position • Your completed corrected tracing will appear similar to this • Repeat the same procedures for the other band

  13. Sacro-coccyx junction Adjusting Paraspinal Bar Tracing • On the paraspinal tracing the S marks the inferior angle of the scapula • Using a flexible tape as before, follow the curves and mark the distance between the inferior angle of the scapula and the sacro-coccyx junction as indicated on the orthometry form Inferior angle of the scapula S

  14. Adjusting Paraspinal Bar Tracing • The lower mark is referred to as the corrected inferior mark Inferior angle of the scapula S Sacro-coccyx junction (corrected inferior mark)

  15. Adjusting Paraspinal Bar Tracing • Measure 3/4” up from this mark to determine the adjusted inferior level • This mark represents the bottom of the pelvic band Inferior angle of the scapula S Adjusted inferior level Sacro-coccyx junction (corrected inferior mark)

  16. Adjusting Paraspinal Bar Tracing • Measure 1 1/4” below the inferior scapular angle to determine the adjusted superior level • This mark represents the top of the thoracic band S 1 1/4” Adjusted superior level Adjusted inferior level Sacro-coccyx junction 3/4” (corrected inferior mark)

  17. Adjusting Paraspinal Bar Tracing • Measure 1 1/2” below the corrected superior level to determine the thoracic band bend mark • This mark represents the bottom of the thoracic band Inferior angle of the scapula S 1 1/4” Adjusted superior level 1 1/2” Thoracic band bend mark Adjusted inferior level Sacro-coccyx junction 3/4” (corrected inferior mark)

  18. Adjusting Paraspinal Bar Tracing • Measure 1 1/2” up from the adjusted inferior level to determine the pelvic band bend mark • This mark represents the top of the pelvic band Inferior angle of the scapula S 1 1/4” Adjusted superior level 1 1/2” Thoracic band bend mark Pelvic band bend mark Adjusted inferior level 1 1/2” Sacro-coccyx junction 3/4” (corrected inferior mark)

  19. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Adjusting Paraspinal Bar Tracing • Place a ruler on the posterior side of the tracing • Move the ruler anteriorly until the edge touches the tracing at both the pelvic and thoracic band bend marks S S Thoracic band bend mark Pelvic band bend mark

  20. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Adjusting Paraspinal Bar Tracing • Draw lines 1 1/2” long up and down from their respective bend marks S S Thoracic band bend mark Pelvic band bend mark

  21. S Thoracic band bend mark 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Pelvic band bend mark Adjusting Paraspinal Bar Tracing • Your finished tracing should look like this

  22. Adjusting Paraspinal Bar Tracing • With the bands attached

More Related