  1. Varian IntegrationSystem TrueBeam 2.0 New Features

  2. TrueBeam 2.0Standard Package Usability enhancements Automation for more fields (gated fields, bolus) Field reordering on treatment application Gotonext field inside bunker (MutiIso Center) Performance improvements for large plans with IGMA multi-core architecture Improvements in the match GUI (16:9 monitors) Imaging improvements

  3. TrueBeam 2.0Standard Package QA mode improvements • Match and Shift • Adhocimaging • Automation • Gotofor couch axes • Edit/Acquire/Override • Background color change for QA mode

  4. TrueBeam 2.0Standard Package • Advanced IGRT & Motion Package • Motion Management Interface • Dynamic Tracking (MLC tracking, Couch tracking) (Developer Mode) • Varian 6DoF Couch • 2.5X Imaging Beam (2.5MV)

  5. TrueBeam 2.0Standard Package Advanced IGRT & Motion Package • 2D/3D match • On-demand imaging • On-line match approval (on-line review) • Triggered Image acquisition (mu,time,angle) • Structures on pre-Txfluoro and kV radiographs • Advanced Reconstructor (4D CBCT, multi-scan CBCT)

  6. TrueBeam 2.0Standard Package • Pause the treatment and verify patient setup • kV radiograph • kV/MV image pair • Reference image will be calculated automatically at any gantry angle • Calculate and apply shift • Continue treatment

  7. Advanced IGRT & Motion PackageTrigered Image acquisition

  8. Advanced IGRT & Motion PackageTrigered Image acquisition • Image acquisition during treatment delivery • Respiration • Time • Gantry angle • Monitor units • Reference image is calculated automaticaly • Eclipse structures can be displayed

  9. Advanced IGRT & Motion PackageTrigered Image acquisition

  10. Advanced IGRT & Motion PackageAdvanced Reconstructor - 4D CBCT

  11. Motion Management - Tracking TrueBeam 2.0

  12. TrueBeam™ 2.0Dynamic MLC/Couch Tracking

  13. TrueBeam™ 2.0Dynamic MLC/Couch Tracking

  14. TrueBeam™ 2.xSmall Treatment Room Solution Minimal distance from isocenteruntillwall: 2.87 meter • TrueBeam ‚Long‘: 3.50 meter • Silhouette: 2.92 meter • TrueBeam ‚Slim‘: 2.87 meter • UNIQUE: 2.40 meter