GE Interlogix Kalatel Programming Update for KTD-405 Keypad
Learn how to program the KTD-405 keypad for enhanced security settings and operations. The guide covers supervisor programming, accessing menus, resetting defaults, and customizing settings. Ensure optimal functionality with detailed instructions.
GE Interlogix Kalatel Programming Update for KTD-405 Keypad
E N D
Presentation Transcript
GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations
KTD-405 keypad (Supervisor Programming) Boot-Up Screen KEYPAD ADDRESS: 99 KEYPAD 99
KTD-405 keypad (Supervisor Programming) Default display after applying power CAMERA --- MONITOR 1
KTD-405 keypad (Programming) Navigating the menus
KTD-405 keypad (Programming) Menus that were not available in the first releases of software are indicated by two beeps and the following display: NOT IMPLEMENTED
KTD-405 keypad (Supervisor Programming) To Access Programming: • Press and hold the key • The unit will beep and show the following display • Remote device programming must be accessed separately. • Supervisor programming password is 1,4,7,6, • Also includes All user programming ENTER PROGRAMMING CODE:
KTD-405 keypad (Supervisor Programming) Resetting the Factory Defaults • The first menu to display will be this one. • Press to advance to the next menu and to return to the previous menu at any time without changing any existing parameters RESET TO DEFAULTS? NO <+>=YES <->=NO NEXT
KTD-405 keypad (Supervisor Programming) If you pressed “+” (yes): • The next display will show: • Followed by: • Followed by: • The keypad will advance to the next menu automatically 1=RESET ALL BUT TITLES 2=RESET ALL ARE YOU SURE? <+>=YES <->=NO NEXT INITIALIZING DEFAULTS PLEASE WAIT
KTD-405 keypad (Supervisor Programming) Setting The Keypad Address • The address is a “user defined” two-digit number • The address must be from 10 to 99 • Each device on the RS-485 network must have a unique address • Address 99 is automatically assigned when the keypad is first connected and will remain unless changed by the user • Entering an address that is already used temporarily displays: • Select or to skip over this menu KEYPAD ADDRESS: 99 (01-99) NEXT ADDRESS NOT AVAILABLE
KTD-405 keypad (Supervisor Programming) Backward Compatibility? • If the KTD-405 is being used in a system with: • Existing ProBridges • Existing CBR-KB3 or CBR-KB3/J keypads • Select YES to allow the KTD-405 to communicate properly with these devices. • Select or to skip over this menu KB3 PTZ PROTOCOL? NO <+>=YES <->=NO NEXT
KTD-405 keypad (Supervisor Programming) Allow Remote Programming by user? • If the KTD-405 is being used in a system with: • Matrix Switchers or Multiplexers • Alarm Monitoring Equipment • Programmable Dome Cameras or Receivers • Select YES to allow the user to enter the 9,5,1, password and program these devices • Select or to skip over this menu ENABLE REMOTE PRGMG? YES <+>=YES <->=NO NEXT
= , = , = , = , KTD-405 keypad (Supervisor Programming) Programming Keypad Titles • A keypad title can be up to 14 characters including: • A – Z and 0 - 9 • Keypads with titles can use the “Seize Control” option • Supervisors can seize camera sites, multiplexers, VCRs, etc. • Supervisors can seize an entire zone in the ZONE mode • Use the joystick or these buttons to program the title • Select or to skip over this menu KEYPAD TITLE: <> NEXT
KTD-405 keypad (Supervisor Programming) Changing the SEIZE CONTROL code • Use the number keys to enter the new code • The keypad will advance to the next menu when the last digit is entered • Select or to skip over this menu SEIZE CONTROL CODE: 8642 USE NUMBER KEYS NEXT
KTD-405 keypad (Supervisor Programming) Changing the SEIZE CONTROL time • Use the number keys to enter the new time • This is the number of minutes of inactivity before the keypad will exit the seize control mode • Select or to skip over this menu SEIZE CONTROL TIME: 5 (1-10) MINUTES NEXT
KTD-405 keypad (Supervisor Programming) Restricting access to presets • Use the number keys to enter the new limit • This is the lowest preset number a user may change • Select or to skip over this menu LOWEST USER PRGMD PRESET (01-64) 58 NEXT
KTD-405 keypad (Supervisor Programming) Programming the SOFT keys • This feature is not yet implemented • Select -, or to skip over this menu • Pressing + displays the following message: PROGRAM SOFT KEYS? <+>=YES <->=NO NEXT NOT IMPLEMENTED
KTD-405 keypad (Supervisor Programming) Programming the ACCESS codes • This feature is not yet implemented • Select -, or to skip over this menu • Pressing + displays the following message: CHANGE ACCESS CODES? <+>=YES <->=NO NEXT NOT IMPLEMENTED
KTD-405 keypad (User Programming) To Access User Programming: • Press and hold the key • The unit will beep and show the following display • User programming password is 5,7,9, ENTER PROGRAMMING CODE:
= , = KTD-405 keypad (User Programming) Changing the Operating Mode • Two choices are available: • Digiplex • Zone • Use the joystick or these buttons to select the mode • Select or to skip over this menu OPERATING MODE: DIGIPLEX <,>=SELECT NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Setting the system size • Enter the highest camera number in your system • Select or to skip over this menu SYSTEM SIZE: <CAMERAS> 511 NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Setting the system size • Enter the highest monitor number in your system • Select or to skip over this menu SYSTEM SIZE: <MONITORS> 64 NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Setting the system size • Enter the highest multiplexer number in your system • Select or to skip over this menu SYSTEM SIZE: <MPLXS> 32 NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Setting the system size • Enter the highest VCR number in your system • Select or to skip over this menu SYSTEM SIZE: <DSR/VCR> 32 NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Setting the system size • Enter the highest preset number in your system • Select or to skip over this menu SYSTEM SIZE: <PRESETS> 63 NEXT
= , = KTD-405 keypad (User Programming) DigiPlex mode Menus Restricting system access • This menu restricts access to specified cameras • Use the joystick or these buttons to select the camera • Select or to skip over this menu CAMERA 000 ACCESS? YES <+>=YES <->=NO NEXT
= , = KTD-405 keypad (User Programming) DigiPlex mode Menus Restricting system access • This menu restricts access to specified cameras • Use the joystick or these buttons to select the camera • Select or to skip over this menu CAMERA 000 ACCESS? YES <+>=YES <->=NO NEXT
= , = KTD-405 keypad (User Programming) DigiPlex mode Menus Restricting system access • This menu restricts access to specified monitors • Use the joystick or these buttons to select the monitor • Select or to skip over this menu MONITOR 01 ACCESS? YES <+>=YES <->=NO NEXT
= , = KTD-405 keypad (User Programming) DigiPlex mode Menus Restricting system access • This menu restricts access to specified recorder • Use the joystick or these buttons to select the recorder • Select or to skip over this menu • Pressing “+” displays this menu: • Enter a number from 0 to 511, or 0 for NONE or • Select or to skip over this menu DSR/VCR 01 ACCESS? YES <+>=YES <->=NO NEXT VCR 01 MATRIX INPUT: 000 <0=NONE> NEXT
= , = KTD-405 keypad (User Programming) DigiPlex mode Menus Restricting system access • This menu restricts access to specified multiplexer • Use the joystick or these buttons to select the multiplexer • Select or to skip over this menu MPLX 01 ACCESS? YES <+>=YES <->=NO NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus If you pressed “+” (yes): • The next display will show: • Followed by: • Followed by: • The keypad will advance to the next multiplexer menu automatically MPLX01 BRAND CBR DVMRe <,>=SELECT NEXT MPLX 01 MATRIX INPUT? 000 <0=NONE NEXT SELECT MAX OUTPUTS: 02 <,>=SELECT NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Programming the monitor offset • Enter a number for the offset needed in your system • Select or to skip over this menu MONITOR OFFSET NUMBER: 0 NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus Queuing and announcing call-ins • If you select “+” in this display: • You need to select either SINGLE or MULTIPLE tone here: • Also specify a monitor to display the queued calls: • Select or to skip over this menu ANNUNCIATION? NO <+>=YES <->=NO NEXT CALL TONE TYPE? MULTIPLE <,>=SELECT NEXT SPOT MONITOR NUMBER: 0 <0=UNASSIGNED> NEXT
KTD-405 keypad (User Programming) DigiPlex mode Menus End of menus notification • Pressing from the previous menu will cause the keypad to display this message: • Select or press and hold for 3 seconds to exit the menus PRESS <SEQ> FOR 3 SECONDS TO EXIT
= , = KTD-405 keypad (User Programming) Changing the Operating Mode • Two choices are available: • DigiPlex • Zone • Use the joystick or these buttons to select the mode • Select or to skip over this menu OPERATING MODE: ZONE <,>=SELECT NEXT
KTD-405 keypad (User Programming) Zone mode Menus Programming the Mode label • This menu allows you to select one of several labels for the LCD display during normal operations • Selections Include: • ZONE, MPLX, DVMR, TERR, BLDG • FLR, DEPT, STA, SITE, AREA • Select or to skip over this menu LCD DISPLAY LABEL: ZONE <,>=SELECT NEXT
KTD-405 keypad (User Programming) Zone mode Menus Programming the zone titles • This menu allows you to select a title to display when the specified zone is being accessed. • Select or to skip over this menu • Enter a two-digit code and the keypad will advance to the following menu automatically • Program the label characters the same way as keypad titles • Select or to skip over this menu ENTER ZONE ADDRESS: 01 (01-16) NEXT ZONE 01 TITLE: <> (01-16) NEXT
KTD-405 keypad (User Programming) Zone mode Menus Programming the Zone type • This menu allows you to identify the specific device that makes up a zone: • Selections Include: • CALIBUR MMX, CBR DVMRe, CBR TRIPLEX, • CBR DUPLEX, CBR SIMPLEX, MATRIX SWCH, • Select or to skip over this menu ZONE 01 HUB: CBR DVMRe <,>=SELECT NEXT
= , = KTD-405 keypad (User Programming) Zone mode Menus Setting the zone size (monitors) • This menu restricts access only to available zone monitors • Use the number buttons to set the number of monitors • Select or to skip over this menu Setting the zone size (cameras) • This menu restricts access only to available zone cameras • Choices include 4, 9, 10, 16 and 32 • Use the joystick or these buttons to select the mode • Select or to skip over this menu ZONE 01 MON. OUTPUTS? 01 TO 02 NEXT ZONE 01 CAM. INPUTS? 16 <,>=SELECT NEXT
KTD-405 keypad (User Programming) Zone mode Menus Programming zone access privileges • Program the cameras that this keypad can access: • Program the monitors that this keypad can access: • Program user access to the zone’s recorder : • You should deny access unless you have a Triplex or MMX connected to a VCR using sub-macros. ZONE 1 CAM 01 ACC? YES <+>=YES <->=NO NEXT ZONE 1 MON 01 ACC? YES <+>=YES <->=NO NEXT ZONE 1 RECORDER ACC? YES <+>=YES <->=NO NEXT
KTD-405 keypad (User Programming) Zone mode Menus If the Zone type is set to MATRIX SWCH: • The zone size and access menus displays are slightly different ZONE 02 HUB: MATRIX SWCH <,>=SELECT NEXT
KTD-405 keypad (User Programming) Zone mode Menus Programming zone size • Program the first camera input number for this zone: • Program the number of monitors for this zone: • Program the number of camera inputs on this zone: • Choices include 4, 9, 10, 16 and 32 SELECT START INPUT: 032 <,>=SELECT NEXT ZONE 02 MON. OUTPUTS: 01 TO 16 NEXT ZONE 02 CAM. INPUTS: 64 <,>=SELECT NEXT
KTD-405 keypad (User Programming) Zone mode Menus Programming zone access privileges • Program the cameras that this keypad can access: • Program the monitors that this keypad can access: • Program user access to the zone’s recorder : • You should deny access unless you have a Triplex or MMX connected to a VCR using sub-macros. ZONE 02 CAM 01 ACC? YES <+>=YES <->=NO NEXT ZONE 02 MON 01 ACC? YES <+>=YES <->=NO NEXT ZONE 02 RECORD ACC? YES <+>=YES <->=NO NEXT
KTD-405 keypad (User Programming) Zone mode Menus Queuing and announcing call-ins • If you select “+” in this display: • You need to select either SINGLE or MULTIPLE tone here: • Also specify a monitor to display the queued calls: • Select or to skip over this menu ANNUNCIATION? NO <+>=YES <->=NO NEXT CALL TONE TYPE? MULTIPLE <,>=SELECT NEXT SPOT MONITOR NUMBER: 0 <0=UNASSIGNED> NEXT
KTD-405 keypad (User Programming) Zone mode Menus End of menus notification • Pressing from the previous menu will cause the keypad to display this message: • Select or press and hold for 3 seconds to exit the menus PRESS <SEQ> FOR 3 SECONDS TO EXIT
KTD-405 keypad (Remote Programming) To Access Remote Programming: • Press and hold the key • The unit will beep and show the following display • User programming password is 9,5,1, • Correct password entry will cause the following display: • Each selection generates a different set of menus ENTER PROGRAMMING CODE: 1=SWITCHER/MPLX 2=ALARMS 3=CAMERA/RCVR EXIT
KTD-405 keypad (User Programming) Switcher/Mux Menus Switcher/Multiplexer Programming • Identify the device to be programmed • If you select “1” (440) enter the monitor number to use for programming the switcher • The keypad will display this message 1=440 2=CALIBUR 3=340/348 BACK ENTER MONITOR NUMBER: (1-64) BACK SEE MONITOR FOR MENUS HOLD SEQ <3 SEC> TO EXIT