1 / 6

Update on the Muon detector layout and readout channel number

Update on the Muon detector layout and readout channel number. Burkhard Schmidt 28.03.2011. What was wrong previously. The barrel and end-cap yoke of CLIC ILD, is not an octagon but a dodecagon. Thanks to Erik for pointing this out to me

susane
Télécharger la présentation

Update on the Muon detector layout and readout channel number

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Update on the Muon detector layout and readout channel number Burkhard Schmidt 28.03.2011

  2. What was wrong previously • The barrel and end-cap yoke of CLIC ILD, is not an octagon but a dodecagon. • Thanks to Erik for pointing this out to me • This is still wrong on some of the drawings for the infrastructure. • For CLIC SiD, this is indeed an octagon. • NB: opposite to ILD, SiD has a dodecagon inside the coil for ECAL and HCAL. ILD has here octagons. • Is all this motivated by physics . . . ?

  3. Update on area to be covered CLIC - SiD: Comments: • In case of scintillators as technology, 2 layers are mandatory to get the 2 coordinates. • Area went up by about 25m2/layer • Single layer for CLIC-ILD a bit larger due to bigger solenoid • Area went up by about 125m2 since last time. CLIC - ILD:

  4. Channel numbers CLIC-SiD CLIC - SiD: Comments: • Large difference comes from the end-caps • SiD doesn’t take into account that long vertical strips are not feasible. Barrel: 5.7 m long; 14 barrels; axial 10, 025 ; (r,f) 15,570 Sum 25,595 Forward/Backw’d (x,y) Quads RFe = 5.5 m, 4 quads X2 (x,y) [1,072] 14 planes X2 forw/back F+W 30, 016 Readout ch’s25,595 + 30,016 = 55,611 Standard SiD:

  5. Update on channel numbers CLIC-ILD CLIC - ILD: Comments: • Assumed a full pad readout. • The HARDROC chip (64 channels) but also the present version • of the 64 channel version of the KPIX chip seem to be suitable.

More Related