An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CMS CMS Data Services is Your TOTAL SOLUTION COMPANY DATA CENTER SERVICES & PRODUCTS

  2. Why Should You Clean Your Data Center? • Dirt, dust, carbon, construction debris, calcium carbonate, paper dust, synthetic fibers, human and non-human organic fibers and other un-seen sources of contamination are leading causes of internal corrosion and equipment malfunction in today’s computer systems.

  3. Manufacturer’s Quotes • Fuji Film: regarding high performance magnetic particles and a magnetic layer .2um thick ATOMM-II technology, “Even with a special black coating to keep the friction coefficient consistently low, there is friction. Friction product equals metal particles that get airborne and move through mission-critical systems”. • IBM states in their systems support manual: “Many failures are caused by dirt and fiber particles, which pick up a minute electrical (static) charge and attach to the recording head surfaces…Hardware and application maintenance is critical to keep your systems running at peak performance. Unplanned interruptions shouldn’t impact your business”. • HP acknowledges that during recent years a growing concern has developed in computer rooms where conductive contaminates (metallic particulate contamination) are formed on the bottom of some raised floor tiles. HP recommendation: “…your site be evaluated for metallic particulate contamination before installation of electronic equipment since metallic contamination can cause permanent or intermittent failures on your electronic equipment”.

  4. The CMS Solution • CMS Data Services has a national network of operations managers and technicians who specialize in data center cleaning. • Data Center Cleaning Services we offer: • Environmental Analysis (airborne particulate testing, ferrous metal tests, concrete seal integrity, etc.) • Sub-floor Cleaning • Equipment Cleaning • Floor Surface Cleaning • Concrete Seal • Disaster Recovery • Zinc Whisker Testing and Abatement

  5. Subfloor Cooling & Airflow Air stratification efficiency requires a balanced airflow Maximizing data center cooling efficiency through Cooling Capacity Balancing Two keys to increased cooling capacity Balanced airflow Managed airflow

  6. Managed airflow(Eliminating unmanaged openings) • Lost air from ‘cable cut outs’ create a short circuit of airflow. (Air that returns to the ‘Computer Room Air Conditioner’ without passing through a heat load) • A great deal of Airflow can be recouped and redirected to the thermal load by covering these openings

  7. High velocity air flow • High air velocity creates harmful airflow patterns that negatively affect air pressures. • Perforated tiles located at places where there is improper airflow velocity will cause the perforated tile not to flow to its fullest potential.

  8. How does inefficient subfloor air delivery affect you? Makes for inefficient • Cooling capacity • Overall air stratification

  9. Uncontrolled subfloor air velocity hurts cooling capacity • Which causes: • Inefficient thermal load removal • Hot spots • Cool air not to reach equipment on high racks • Not fully populating equipment racks • Limits placement of equipment on all areas of the floor • Energy to be wasted LOW MEDIUM HIGH AIR PLUMES

  10. Insufficient airflow from the perforated tiles hurts air stratification Stratification requires both high CFM and balanced volume of airflow to the thermal load

  11. Until now subfloor velocity has been totally overlooked… NOW there is a system to eliminate problems due to airflow velocity

  12. The Solution: • Engineer subfloor airflow solutions with Computer Fluid Dynamics (CFD) • Adjust the subfloor airflow velocity to enable perforated tiles to maximize their airflow • Eliminate cable cut out short circuits • Provide continuous engineering support for continued airflow management

  13. Before and after example Low and Uneven Airflow High and Even Airflow

  14. Perforated tile comparisonbefore and after subfloor Low Velocity – High Velocity

  15. Next step • Build a Computer Fluid Dynamics (CFD) of your data center (complete with air-balancing analysis) • Compare side-to-side with engineered solution • Analyze the energy savings

  16. ComputationalFluid Dynamics (CFD) • What We Need… • Plenum height • Location and flow rate of CRAC • Perforated tile arrangement • Cable cut-out openings • Under floor obstructions What We Deliver • We provide quick, reliable, and cost-effective solutions to computer cooling needs by first calculating the airflow rates based on the current configuration of your data center; then engineer a solution with our program. • Finally, we will offer you a side-by-side comparison.

  17. Relocation Services CMS Our data center relocation services include: • Conducting a complete inventory of assets • Monitoring asset movement • Selecting qualified contractors • Implanting security measurements • Minimizing potential downtime by identifying and analyzing potential risks • Ensuring that transportation can handle capacity • Checking connectivity requirements at the new location • Ensuring quality cabling methods • Assist IT department in network connectivity issues

  18. CMS Access Floor Panels (Parts & Installation) • New Floor Panels • Replacement Parts • Used Floor Panels • Floor Adjustment/Leveling • Complete Construction • Remodeling • Zinc Whisker Abatement

  19. CMS Contamination Audits/Lab Services • CMS Data Services provides a full range of inspection and testing services to identify contaminants and soil, verify the source, and offer solutions to fix the problem.

  20. CMS Environmental and Security Monitoring Systems • What do you want to monitor – we have the solution! • Temperature • Water • Humidity • Smoke • Security Concerns • Our solutions monitor environmental and equipment parameters at remote and/or critical sites. No external PC or software is required for it to function. Contact us for specific information.

  21. Inventory and Audit Services CMS • 70% of organizations have a 30% discrepancy between a planned inventory and their actual inventory. • Major reasons to conduct an inventory • Planning and orchestrating moves • Leverage pre and post-merger and acquisition activities • IT Help desk – asset database reset • Maximize liquidation and dispositions • Lease verification and tracking • Software licensing compliance • Audit and regulatory issues Whether your company is large or small, sooner or later you will need to update your master list of IT Assets. Call on CMS Data Services to ensure consistent and accurate data capture.

  22. CMS Additional Services • Power Audits • Cable Mining and Organization • Cleanroom Cleaning and Maintenance • Disaster Recovery • Cleaning and Contamination Control Supplies: Tacky mats, tile pullers (stand-up and regular), cleaning solutions and supplies, static-dissipative v-belts for air-handlers, HEPA and ULPA-filtered vacuums, filters for air-handlers, cleanroom supplies.

  23. Contact Us: CMS CMS Data Services Mark Kempin Direct: 973-317-2810 Cell: 201-532-6486 mkempin@callsms.com Your TOTAL SOLUTION COMPANY

More Related