An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PARAID:A Gear-ShiftingPower-Aware RAID Charles Weddle, Mathew Oldham, Jin Qian, An-I Andy Wang – Florida St. University Peter Reiher – University of California, Los Angeles Geoff Kuenning – Harvey Mudd College

  2. Motivation • Energy costs are rising • An increasing concern for servers • No longer limited to laptops • Energy consumption of disk drives • 24% of the power usage in web servers • 27% of electricity cost for data centers • Root to other issues, e.g. server room cooling • Is it possible to reduce energy consumption in RAID devices without degrading performance while maintaining reliability? PARAID: A Gear-Shifting Power-Aware RAID

  3. Challenges • Energy • Not enough opportunities to spin down RAIDs • Performance • Essential for peak loads • Reliability • Server-class drives are not designed for frequent power switching PARAID: A Gear-Shifting Power-Aware RAID

  4. Existing Work • Most trade performance for energy savings directly. • For example, vary the speed of disks • Most are simulated results PARAID: A Gear-Shifting Power-Aware RAID

  5. Observations • Over provisioning of resources • RAID is configured for peak performance • RAID keeps all drives spinning for light loads • Unused storage capacity • Over-provision of storage capacity • Unused storage can be traded for energy savings • Fluctuating load • Cyclic fluctuation of loads • Infrequent on-off power transitions can be effective PARAID: A Gear-Shifting Power-Aware RAID

  6. Power-Aware RAID • Skewed striping for energy savings • Preserving peak performance • Maintaining reliability • Evaluation • Conclusion • Questions PARAID: A Gear-Shifting Power-Aware RAID

  7. 1 2 3 4 5 Soft State RAID Gears 1 2 3 Skewed Striping for Energy Saving • Use over-provisioned spare storage • Can use fewer disks for light loads PARAID: A Gear-Shifting Power-Aware RAID

  8. Skewed Striping for Energy Saving • Operate in gear 1 • Disks 4 and 5 are powered off 1 2 3 4 5 Soft State RAID Gears 1 2 3 PARAID: A Gear-Shifting Power-Aware RAID

  9. Skewed Striping for Energy Saving • Approximate the workload • Gear shift into most appropriate gear • Minimize the opportunity lost to save power Conventional RAID PARAID Energy ( Powered On Disks ) workload Workload ( Disk Parallelism ) PARAID: A Gear-Shifting Power-Aware RAID

  10. load utilization threshold gear shift time Skewed Striping for Energy Saving • Adapt to cyclic fluctuating workload • Gear shift when gear utilization threshold is met PARAID: A Gear-Shifting Power-Aware RAID

  11. Preserving Peak Performance • Operate in the highest gear • When the system demands peak performance • Uses the same disk layout • Maximize parallelism within each gear • Load is balanced on each gear • Uniform striping pattern within each gear • Delay block replication until gear shifts • Track block writes as an optimization PARAID: A Gear-Shifting Power-Aware RAID

  12. Maintaining Reliability • Reuse existing RAID levels (RAID-5) • Also used in soft state • Drives have a limited number of power cycles • Ration number of power cycles PARAID: A Gear-Shifting Power-Aware RAID

  13. Admin Tool User Space Linux kernel File System RAID Reliability Manager PARAID Block Handler Monitor Soft RAID Disk Manager Disk Device Driver Logical Component Design PARAID: A Gear-Shifting Power-Aware RAID

  14. Data Layout • Parity for 5 disks does not work for 4 disks • For example, replicated block 12 on disk 3 PARAID: A Gear-Shifting Power-Aware RAID

  15. Data Layout • Cascading parity updates • Must also update parity in soft state PARAID: A Gear-Shifting Power-Aware RAID

  16. Update Propagation • Up-shift propagation • Full synchronization • On-demand synchronization • For example, shifting from 3 to 5 disks • Downshift propagation • Full synchronization PARAID: A Gear-Shifting Power-Aware RAID

  17. Asymmetric Gear-Shifting Policies • Up-shift (aggressive) • Moving average + moving standard deviation > threshold • Downshift (conservative) • Modified moving average + moving standard deviation < threshold • Moving average modified to account for extra parity updates PARAID: A Gear-Shifting Power-Aware RAID

  18. Implementation • Prototyped in Linux 2.6.5 • Open source, software RAID • Implemented block I/O handler, monitor, disk manager • Implemented user admin tool to configure device • Updated Raid Tools to recognize PARAID level PARAID: A Gear-Shifting Power-Aware RAID

  19. Evaluation • Challenges • Prototyping PARAID • Commercial machines • Benchmarks are designed to measure peak performance • Trace replay • Time consuming PARAID: A Gear-Shifting Power-Aware RAID

  20. client RAID USB cable P4 2.8 Ghz, 1 GB RAM 160 GB 7200 RPM SATA RAID crossover cable RAID multimeter RAID server power measurement probes Xeon 2.8 Ghz, 512 MB RAM 36.7 GB 10k RPM SCSI RAID 12v & 5v power lines BOOT SCSI cable power supply Evaluation • Measurement framework PARAID: A Gear-Shifting Power-Aware RAID

  21. Evaluation • Measurement framework PARAID: A Gear-Shifting Power-Aware RAID

  22. Evaluation • Three different workloads using two different RAID settings • Web trace - RAID level 0 – 2 gears (2,5) • Mostly read activity • Cello99 - RAID level 5 – 2 gears (3,5) • I/O intensive workload with writes • Postmark - RAID level 5 – 2 gears (3,5) • Measure peak performance and gear shifting overhead • Speed up trace playback • To match hardware • Explore range of speed up factors and power savings PARAID: A Gear-Shifting Power-Aware RAID

  23. Web Trace • UCLA CS Dept Web Servers (8/11/2006 – 8/14/2006) • File system: ~32 GB (~500k files) • Trace replay: ~95k requests with ~4 GB data (~260 MB unique) PARAID: A Gear-Shifting Power-Aware RAID

  24. Web Trace Energy Savings 64x – 60 requests/sec Energy Savings 64x - 34% 128x - 28% 256x - 10% 128x – 120 requests/sec 256x – 240 requests/sec PARAID: A Gear-Shifting Power-Aware RAID

  25. Web Trace Latency 256x Overhead 256x - within 2.7% 64x - 240% 80ms vs. 33ms 128x 64x PARAID: A Gear-Shifting Power-Aware RAID

  26. Web Trace Bandwidth 256x Overhead 256x - within 1.3% in high gear 128x 64x PARAID: A Gear-Shifting Power-Aware RAID

  27. Cello99 Trace • Cello99 Workload • HP Storage Research Labs • 50 hours beginning on 9/12/1999 • I/O intensive with 42% writes PARAID: A Gear-Shifting Power-Aware RAID

  28. Cello99 Energy Savings 32x – 270 requests/sec Energy Savings 32x - 13% 64x - 8.2% 128x - 3.5% 64x – 550 requests/sec 128x – 1000 requests/sec PARAID: A Gear-Shifting Power-Aware RAID

  29. Cello99 Completion Time 128x Overhead 32x - 1.8ms, 26% slower due to time spent in low gear 64x 32x PARAID: A Gear-Shifting Power-Aware RAID

  30. Cello99 Bandwidth 128x Overhead < 1% degra- dation during peak hours 64x 32x PARAID: A Gear-Shifting Power-Aware RAID

  31. Postmark Benchmark • Popular synthetic benchmark • Generates ISP-style workloads • Stresses peak read/write performance of storage device PARAID: A Gear-Shifting Power-Aware RAID

  32. Postmark Performance PARAID: A Gear-Shifting Power-Aware RAID

  33. Postmark Power Measurements PARAID: A Gear-Shifting Power-Aware RAID

  34. Ongoing Work • Try more workloads • Optimize PARAID gear configuration • Explore asynchronous update propagation • Speed up recovery • Live testing PARAID: A Gear-Shifting Power-Aware RAID

  35. Lessons Learned • Third version of design, early design not portable • Data alignment problems • Difficult to measure system under normal load • Hardware and operating system optimizations • Matching trace environment PARAID: A Gear-Shifting Power-Aware RAID

  36. Conclusion • PARAID reuses standard RAID-levels without special hardware while decreasing their energy use by 34%. • Optimized version can save even more energy • Empirical evaluation important PARAID: A Gear-Shifting Power-Aware RAID

  37. Questions PARAID: A Gear-Shifting Power-Aware RAID

  38. PARAID Gear-Shifting Web Trace Gear-Shifting Stats Cello99 Gear-Shifting Stats

  39. Storage Requirement for PARAID5 Storage consumption Si for the total RAID for the ith gear; • PARAID uses around (D – G1)/(D – 1) of the total RAID-5 storage to store soft states. • For RAID-5, D> 3 disks, M gears with Gi disks within the ith gear (1 < i < M, 3 < Gi < Gi+1 < GM = D)

  40. Storage Requirement for PARAID5 Space needed for extra parity blocks S1(G1 – 1) G2 = 5 G1 = 4 S1 S2 S1 + S2 = 1 S1(G1 – 1) = S2(G2 – G1) S2(G2 – G1)

  41. PARAID Target percentage energy savings; • Energy savings increase with more disks and fewer disks in the lowest gear. • A higher active/standby ratio. • D = the number of disks in the array • G1 = the disks in gear 1. • P = power in standby/active/idle

  42. PARAID Modified moving utilization; • Accounts for cascading parity writes in lower gear. • Gi = the disks in gear i. • Aread/write = the read or write activity • W = the weight to account for additional parity writes • (RAID5 = 1.5)

  43. PARAID