1 / 32

SAFETY & HEALTH

SAFETY & HEALTH. MANAGERS. TIPS AND TOOLS FOR CREATING A RESPIRATOR PROGRAM. INTRODUCTION. Intended As a guide Need to develop program that meets your needs Some of the materials covered are examples Important to remember Supplied Air Respirators and SCBA’s are included

thomaso
Télécharger la présentation

SAFETY & HEALTH

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SAFETY & HEALTH MANAGERS TIPS AND TOOLS FOR CREATING A RESPIRATOR PROGRAM

  2. INTRODUCTION • Intended As a guide • Need to develop program that meets your needs • Some of the materials covered are examples • Important to remember • Supplied Air Respirators and SCBA’s are included • Other Fit testing methods – we’re discussing Bitrex

  3. DEFINITIONS • Air Purifying Respirator (APR) • A respirator with an air-purifying filter, cartridge or canister that removes contaminants • Filtering facepiece – dust mask • End-of service-life (ESLI) • System that warns user that sorbent is approaching saturation or is no longer effective • Qualitative fit test (QLFT) • Pass/Fail test to assess adequacy of respirator fit that relies on individual’s response to the test agent

  4. DEFINITIONS • Quantitative fit test (QNFT) • An assessment of the adequacy of respirator fit by numerically measuring the amount of leakage into the respirator • Immediately dangerous to life and health (IDLH) • An atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual’s ability to escape • Physician or other licensed health care professional (PLHCP) - Doctor

  5. DEFINITIONS • National Institute of Occupational Safety & Health (NIOSH) • is the federal agency responsible for conducting research and making recommendations for the prevention of work-related injury and illness. • Particulate Filter Series (N, P, R) • Testing and certification requirements for filters (NIOSH Part 84). Establishes 3 levels of filter efficiency and filter resistance. • Efficiencies Filter Resistance • 95% N – Not resistant to • 99% R – Resistant to oil • 100% P – Oil Proof • Training Inspiration Point (T. I. P.)

  6. T I P Before using respirators, evaluate the possibility of… • Using Engineering controls by • Opening windows or doors • Using local exhaust fans or chemical fume hoods • Using Administrative controls by • Substituting less hazardous products • Reducing exposure time to chemical • Contracting out work • Working outdoors

  7. Respirator Program WHERE DO I START?

  8. Respiratory Protection Program Elements 1910.134

  9. RECORDKEEPING USE PROGRAM REVIEW TRAINING INSPECTION CLEANING FIT TESTING MEDICAL EVALUATION RESPIRATOR SELECTION WRITTEN PROGRAM

  10. Written Program 1 • Employer must develop a written program with worksite specific procedures when respirators are required by • Label • MSDS; or • Employer • Program must be administered by a suitably trained program administrator • Must update program as necessary to reflect changes in workplace conditions

  11. Voluntary Use • If respirators not required by label or policy: • Employer can provide respirator at employee’s request • Permit employee to use their own • Employer must implement limited written program • Medical evaluation • Maintenance, cleaning and storage • Copy of Appendix D • Employee precautions • READ and HEED all instructions • Use NIOSH certified respirator • Keep track of respirator

  12. Medical Evaluation 2 • A medical evaluation is required for employees who wear respirators • Intended to assure that employees are physically able to wear a respirator • Medical questionnaire • Administered confidentially • Completed on work time • Reviewed and cleared or; • Medical evaluation is needed

  13. Medical Evaluation • Employee needs to be provided an opportunity to discuss the questionnaire and examination results with PLHCP • Following supplemental information must be provided to the PLHCP: • Type/weight of respirator • Duration/frequency of use • Expected physical work effort • Additional PPE to be worn • Temperature/humidity extremes • Copy of written policy and OSHA standard

  14. Medical Evaluation • Annual review of medical status IS NOT REQUIRED • However, at a minimum, employer must provide additional medical evaluations if: • Worker reports medical signs or symptoms related to the ability to use a respirator • PLHCP, supervisor or program administrator has reason to believe a worker needs to be reevaluated • Observations during fit testing and program evaluation indicate need • Change occurs in workplace conditions that may substantially increase physiological burden placed on employee (i.e. temp, protective clothing)

  15. Respirator Selection 3 • Choose the right respirator to protect from contaminant (consult Label and MSDS) • Respirators must be NIOSH approved • Evaluate workplace exposure, assume IDLH if contaminant is unknown • Air purifying respirators cannot be used in IDLH atmospheres • Select from a sufficient number of respirator models and sizes

  16. Cartridge Selection • Check label and MSDS for recommendations • Cartridges must be color coded with NIOSH approval label • Label must not be removed, remain legible and marked with • “NIOSH”, MFG’s name & part number, and cartridge or filter type (i.e. N95, P100 etc.) • For most all pesticides, the following two are recommended: • Dust/mist/fumes filter • No spray oils present: N-95 or P-100 (HEPA) • Spray oils present: R-95 or P-100 (HEPA) • Toxics • Organic vapor cartridge (OV), or OV and acid gas cartridge, or multi-contaminant cartridge

  17. Fit Testing 4 • Must be done prior to use • Must be repeated at least annually or sooner if • A new respirator is introduced • Changes in physical condition occur • Recent dental work, and dentures • Facial surgery, treatments, scars • Weight loss or gain of 15 lbs or more • Fit testing comprised of two parts

  18. Fit Testing TASTE THRESHOLD SCREENING • Test is done to assure person can detect the sweet or bitter taste of test solution • Do not eat, drink (except water) or chew gum for 15 minutes prior to test • Test solution is injected in increments of 10 • Note whether 10, 20, or 30 squeezes produced a taste response • If 30 squeezes is inadequate for taste response, another type of fit test must be used

  19. Fit Testing TEST EXERCISES • Normal breathing while standing • Deep breathing while standing • Turning head side to side while standing • Moving head up and down while standing • Bending over (jogging in place can be used) • Talking (Rainbow Passage) • Normal breathing while standing • Each exercise takes 60 seconds • Inject fit test solution • Use same number of squeezes as required in Taste threshold screening • Inject one-half the number of squeezes every 30 seconds • Test is terminated any time sweet or bitter taste is detected • Wait 15 minutes reposition respirator and retry • Test is complete and successful fit is demonstrated without detection

  20. Respirator Use 5 • Must be medically qualified • No facial hair may come in contact with respirator seal • User seal checks must be performed each time respirator is put on • Never use an air purifying respirator • In oxygen deficient atmospheres • In an IDLH atmosphere • For firefighting or fumigating • Which is not approved for contaminant or hazard • For large chemical spills or leaks or thick dust clouds

  21. Respirator Use • If you experience • Warning signs of taste, smell, irritation, cough • Difficulty breathing, shortness of breath, chest pain • Dizziness, nausea, headache GET OUT OF AREA TO FRESH AIR AND REMOVE RESPIRATOR • What to do • Inspect Respirator • Change cartridges and filters • Put on respirator and conduct fit checks • Re-enter and if conditions persist, exit and inform supervisor • Address medical and exposure symptoms and inform supervisor

  22. Respirator Use Cartridge Change Schedule • Cartridges and filters must be changed regularly • If cartridge has no ESLI then employer must implement a change schedule based on objective information • Three ways to estimate cartridge service life • Experimental Tests • Manufacturer’s recommendation • Math model • Factors that can reduce cartridge service life • Exertion level (i.e. smoker vs non-smoker) • Temperature and humidity • Multiple contaminants

  23. Inspection & Care 6 • Inspect before and after each use and cleaning to ensure all parts are present and operating • What to look for • Dirt, oil, soap or chemical residue • Cracks, tears, holes • Broken parts • Distortion and affects of UV radiation • Valves - do they lay flat and are they present • Check elasticity of straps (any modifications) • Cartridges – damaged, expired, correct ones for job

  24. Storage • Proper storage prevents • Respirator from being distorted causing it to lose its ability to fit properly • Damage (sunlight, temperature, moisture, chemicals) • It from becoming contaminated reducing the protection it can provide • Areas to avoid • Glove compartment • Behind the seat • Hanging from a hook or rear view mirror

  25. Cleaning 7 • Provide each user with a respirator that is clean, sanitary and in good working order • Inspect prior to and after cleaning • A respirator that is not clean can: • Cause a reduced seal • Cause undue wear on certain parts • Lead to skin problems • Use manufacturer’s recommendation for cleaning • Hand or air dry the respirator • Properly store until next use

  26. Cleaning • Daily with a cleaning wipe • Deep cleaning as follows: • Clean in warm water (not to exceed 100o F) • Use a mild detergent • Can use a one-step combination detergent/sanitizer • Wash with a soft sponge • Rinse with running (required) warm water (not to exceed 100o F) • Sanitizing required if reissuing

  27. Training 8 • Must be done prior to use • Training must cover • Why respirator is necessary • Limitations and capabilities of the respirator • Effective use in emergency situations • How to inspect, put on and remove, use and check the seals • Maintenance, care and storage • Must be repeated annually or when • Workplace conditions change • New type of respirator used • Inadequacies in employee’s knowledge or use indicates need DOCUMENT

  28. Program Review 9 Factors that need to be assessed should include: • Respirator fit • Appropriate respirator selection for the hazards to which the employee is exposed • Proper respirator use under the workplace conditions the employee encounters • Proper respirator maintenance

  29. Recordkeeping 10 • Written Program • Medical Certifications • Fit Test Records • Training Records • Air monitoring records

  30. SUMMARY • Written Program • Medical Certifications • Fit Testing • Establish cartridge change schedule • Training • Assistance • OSHA (eTool, Compliance Assistance Specialist, Consultation Service) • PestSure (Linda) • Draeger Representative (Mike Allen)

  31. QUESTIONS

More Related