1 / 17

Wire scanners for LHC LHC-BI Review Workshop 2001 - J. Koopman

Wire scanners for LHC LHC-BI Review Workshop 2001 - J. Koopman. Outline. Basics. SPS and LEP review. LHC requirements. Realization. Principle of operation. Wire interacting with the beam: Secondary Electron Emission. EM pick-up. Thermo-ionic emission.

troy-parks
Télécharger la présentation

Wire scanners for LHC LHC-BI Review Workshop 2001 - J. Koopman

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wire scanners for LHCLHC-BI Review Workshop 2001 - J. Koopman

  2. Outline • Basics. • SPS and LEP review. • LHC requirements. • Realization. Wire scanners for LHC - J. Koopman

  3. Principle of operation Wire interacting with the beam: • Secondary Electron Emission. • EM pick-up. • Thermo-ionic emission. • Shower of secondary highly energetic particles. • Repetitive bunch passing. • Collider. • Linac. shower intensity x wire position = 1-D profile. Wire scanners for LHC - J. Koopman

  4. Rotational wire scanner Wire scanners for LHC - J. Koopman

  5. 1st generation linear wire scanner Wire scanners for LHC - J. Koopman

  6. 2nd generation linear wire scanner Wire scanners for LHC - J. Koopman

  7. Wire supporting fork Wire scanners for LHC - J. Koopman

  8. SPS and LEP wire scanners o Wire material: Be, C, SiO2, SiC. o Wire diameter varying from 5 to 50 um. Wire scanners for LHC - J. Koopman

  9. LHC beam, σ = 1mm Wire scanners for LHC - J. Koopman

  10. LHC beam, σ = 320µm Wire scanners for LHC - J. Koopman

  11. WS as a calibration device o Absolute and direct method of measuring a beam profile. o Good signal quality. o Widely used classical device. o Robust and reliable device. BUT: o Need very stable beam. o Manage the beam energy deposition on the wire. o Limited spatial resolution at high scanning speeds. o Approximately one profile per second. Wire scanners for LHC - J. Koopman

  12. Requirements for the LHC o Accuracy 1-2% for beam sizes down to ~220 um. o Single bunch. o Tail scans at 10-3. o Close to other profile devices. o Negligible beam blow-up. o Prevent quenching SC magnets. o Radiation level ~ 100 Gy/y. BUT: o Compromise on maximum speed 2m/s*. o Limited beam intensity: • Up to 2 Tev: 1/4th*. • From 2 to 7 Tev : 1/8th*. * J. Bosser, C.Bovet, Wire scanners for LHC, LHC Project Note 108-Rev., Oct. 1997. Wire scanners for LHC - J. Koopman

  13. Upgrade program(1/2) o Mechanics: • Actual 2nd generation linear wire scanner with 36 µm C wire. o Position detection: Potentiometer. • Radiation hardness. • Accuracy. o Secondary particle shower detection: PMT. • High current. Wire scanners for LHC - J. Koopman

  14. o Electronics. Profile amplitude read-out. 40Mhz. Wire position read-out. Differential, low noise. Tail scans. Motor drive & power supply. 2-3 kW peak power for 2m/s. PWM technique. o Software. Renovation. New hardware addresses and routines. Fit algorithm. New functions. Tail scans. LUT for correction. Upgrade program(2/2) Wire scanners for LHC - J. Koopman

  15. Expected performance Wire scanners for LHC - J. Koopman

  16. Installation o 2 x H&V downstream 4 D3 L + R. o 2 x H&V downstream 5 D2/Q4 L + R : single bunch. Wire scanners for LHC - J. Koopman

  17. Time scale oDevelopment until: Q2/2004. oProduction preparation: Q2/2004. oManufacturing: Q3-Q4/2004. o Software : Q1/2005. oInstallation: Q1/2005-Q4/2005. oPhysics: Q1/2006. Wire scanners for LHC - J. Koopman

More Related