Virginia Building Code Officials Region 8

Virginia Building Code Officials Region 8. April 20, 2006. Insert picture of the Virginia Beach deck that collapsed. International Residential Code IRC 2003. Section R502.2.1 Where supported by attachment to an exterior wall, decks shall be positively anchored to the

yan
Télécharger la présentation

Virginia Building Code Officials Region 8

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Virginia Building Code OfficialsRegion 8 April 20, 2006

  2. Insert picture of the Virginia Beach deck that collapsed.

  3. International Residential CodeIRC 2003 Section R502.2.1 Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads as applicable. Such attachment shall not be accomplished by the use of toenails or nails in withdrawal.”

  4. Virginia Construction Code added USBC 2003 Section R502.2.1.1 “…the connection between a deck ledger and a 2” nominal band joist bearing on a sill plate or wall plate shall be constructed with 1/2 “ lag screws or bolts with washers per Table R502.2.1.1.” Table R502.2.1.1 FASTENER SPACING FOR DECK LEDGER AND BAND JOIST

  5. International Residential CodeIRC 2003 Section R502.2.1 Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads as applicable. Such attachment shall not be accomplished by the use of toenails or nails in withdrawal.”

  6. Code, Builder, and Inspector • IRC 2003, Section 502.2.1 is a performance based requirement that ensures a level of safety. • The contractor has the latitude to creatively achieve the mandated level of safety. • The building code inspector must determine if he has met that requirement

  7. A single, simple concept was conceived to address all of these variables: Attachment In Shear